My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7090 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7090 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:19:53 PM
Creation date
2/19/2025 12:28:58 PM
Metadata
Fields
Template:
Building Plans
Street #
7090
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22140
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMDRANE FLASHING OVER <br />TOP. SIDE(&) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED &O AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON A L 6, & CAULKING S JOINT <br />ALL <br />PER SECTION RTM.7 <br />EXhWw k0no Its p`SWrw <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 928-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1083-12A. <br />WRB LAYER N, <br />,x <br />. <br />STUCCO WRAP <br />HOODED VENT <br />PLA ICI 9 COAT CEMENT <br />METAL LATH <br />URB LAYER 42, FORTPIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />• ors %//////////// <br />SELF-ADHESIVE FLASHING <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-&41-09, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />LAYER -1. <br />UNIT <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />PREMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />WOOD <br />T/e' TEXTURED <br />CONBTRJOTION <br />��FNISH •WOOD <br />FASTEN TO WOOD STRIGTURAL <br />SEALANT* <br />MEMBER • 1' O.C. MAX <br />TOP SIDES <br />�' utI <br />Tp Jr MID I AIuI <br />WRRP aGILLED <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />I <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METEI <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENNG IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER M, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRAN <br />ENTERS BOX, <br />APPLY TO FA <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />i' WIDE 67" SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY EEFORE APPLYINS <br />® HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />e• <br />WRB LAYER 1, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING';' <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WR6 LAYER <br />STEP 01 <br />STEP 02 <br />UIRB LAYER h, <br />STUCCO WRAP <br />STEP *3 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />® [MEMBRANE FLAt3HNG <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />5TEF *4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />....;AtMETAL <br />LATH <br />STEF *5 STEP I*6 <br />@)ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH: 407-77445078 <br />FAX:407-774+1078 <br />www.abdosoWloup.com <br />AA M: 0003325 <br />z <br />a� <br />7 <br />F <br />RADO <br />#1 <br />#17 <br />02-01171 <br />BB <br />-CALI" <br />Iswtxa <br />LEFT <br />PAOZ: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />