men I r o e r <br />J <br />HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS, <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL DE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLA68 I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PW 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8, ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALE, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED UT14 ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />PANTEC14 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING O O <br />EXTERIOR WALL <br />PLC y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY y <br />REFRIGERANT LINES <br />1 <br />AIR <br />EVAP. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR i WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />ED <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2h3/16'X2' TAFGCONB UNIT 81MP80N WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE 8LA6 SECURE1 1/4'TSTRAP' O IT (2) <br />EXTERIOR WALL <br />y 3/4' PVC CONDENSATE ORAN LINE <br />y PVC SLEEVE TO LINES BELOW SLAB <br />T REFRIGERANT LINES TO <br />RETURN CONDENSINGUNIT <br />VTRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />POOR 6714 EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION 301Z.4 <br />HVAC DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />BRASS PLUG <br />FIN. FLOOR <br />OR WALL <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN CONO. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUW <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />1'-81X8' CONC. <br />LIN <br />OR EXTENSION TO __FITTING OR <br />R WASTE AS EXTENSION TO 601E <br />ED <br />OR WASTE AS <br />240-K J06AM 86000 REQUIRED <br />INSIDE NICKEL BRA66 TOP <br />CAULK PTI/SPEC <br />�NV.��N IY TE AN <br />FLOOR SLAB CLEAN -OUT (TYPN vEXT. GROUND CLEAN -OUT (TYPNiW <br />MECHANICAL PLAN <br />SCALE. 1/4' • 1'-0' <br />■ <br />6 <br />Groupg� <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.774-6078 <br />FAX: 407-774-4078 <br />www.abdoOgngroup.com <br />AA N: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: $13886.2628 <br />FAX: 813886-2802 <br />Dw 10/30/20 <br />MICALM: 1/4"=l'-0" <br />BILE= <br />M1 <br />