My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7096 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7096 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:42:28 PM
Creation date
2/19/2025 11:34:08 AM
Metadata
Fields
Template:
Building Plans
Street #
7096
Location
Silverado Ranch Blvd
Contractor
DR Horton
Building Plans - Permit #
21859
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLI7Cs. CODE SECTION 603. <br />3. ALL FLEX DUCTS 844ALL BE APPROVED UL IN CLASS I AIR DUCT AS PER NFPA 90A 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SERER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(20F) MECHANICAL CODE 603U <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO W<k RECOMMENDATIONS AND FBC 6T44 <br />EDITION (20T) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T 1 <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />d <br />REFRIGERANT LIDS <br />L <br />AIR HANDLER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />b <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TER'9MATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION Mr2.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN • LIGHT <br />O/A <br />OUTSIDE AIR <br />Q <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO GONG. CONDENSER <br />W/ (2)-3/16'X2' TAPC0NS UNIT SIMPSON LLB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE BLAB SECURE STRAP TO WIT W/ (2) <br />JSXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAM 3/4' DIA <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK EEC <br />G.O. PLUG <br />SEE SPEC. <br />FIN. GRADE <br />OR PAVING <br />1'-8'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nFLOOR SLAB CLEAN -OUT (TYPE) NEXT. GROUND CLEAN -OUT (TYPN1 <br />MECHANICAL PLAN <br />SCALE: 1/4 " P-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abde 4Mmup.com <br />AA #: 0003325 <br />a <br />d <br />W <br />L <br />� <br />� <br />3 <br />Q <br />YL <br />• <br />aS <br />LLi <br />e <br />s%mDIv & LOT: <br />SILVERADO <br />LOT #21 <br />BLK #7 <br />PROJECT# <br />04128.002-21071 <br />MODEL: <br />4ENB <br />"1751-NEUVILLE" <br />GA2eAGE 3111117x0: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />50 MPH EXP. <br />DA 08/04/19 <br />SCALE: 1/4"=1'-0" <br />812EET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.