I <br />H-20'-1' BLDG. HGT. <br />SHINGLE <br />10'-0' <br />HEEL HGT. <br />V-4' BRG. HGT. _ <br />Ns'X60'— <br />DECORATIVE <br />SHUTTER <br />S' STUCCO — <br />BANDING <br />TT'P. <br />CAP <br />STONE_ <br />0'-O' FIN. FLR VENEER <br />9'-4' BRG. WT.s _ <br />0'-0' FIN. FLR <br />0'-S' G (MIN.) �— <br />AREA OF ATTIC <br />= 3972 SQL FT. <br />NET FREE VENTILATION AREA REQUIRED <br />= 1/300 <br />REQUIRED VENTILATION AREA <br />= 3972 /300 <br />= 13.24 <br />VENTILATION AREA X SQ. INCHES PER FT. (144) <br />= 1906.56 SO, IN. <br />MIN. REQUIRED VENTILATION <br />= .SX 1906.56 <br />IN UPPER PORTION OF ATTIC <br />953.28 SQ. IN. <br />OFF RIDGE VENTILATION AREA = 11S SQ. IN. PERVENT <br />953.28 / 115 <br />TOTAL#OFVENTSREQUIRED = 8,28939 <br />TOTAL#OFVENTSPROVIDED = 9 <br />FRONT ELEVATION <br />TEXTURED FINISH <br />NOTE. WALL FENESTRATION FLASHING AS PER FBCR R103.4 <br />STONE VENEER TO BE INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS <br />REAR ELEVATION <br />TEXTURED FINISH <br />9'� 4' BRG. HGT. <br />_ 0'-0' FIN. FLR <br />0'-S' G D (MIN.) <br />"AREA OF ATTIC IS THE PERIMITER OF THE HOUSE, LESS THE OVERHANG <br />— — — — — — — — — — — — — — — — — — — — — — <br />I I <br />I PRE-ENGMEERED I I <br />I TF41W I <br />( 9 -4� BRG. HGT. <br />I � I <br />I - I <br />(2) 2XI2 BM <br />I TRUSS TO REAM I <br />( CONNECTION W/ 1..0. <br />SIMPSON HM9A <br />OR LGT2 W/ 10d <br />X I I' HM NAILS, <br />I FILL ALL HOLES. I I <br />I <br />4x4 P.T. POST <br />I POST TO BEAM 1 III < I <br />POST TO CM <br />CONNECTION W1 I 1'-4- 0 <br />I SIMPSON OR EdIUAL III I <br />I I <br />FOAM CAP <br />I 1 <br />I � I <br />STONE v <br />VENEER <br />0'-0' FIN. FLR <br />I I <br />\`-------------------------// <br />COLUMN DTL. <br />A ecALE.I/7.I'-0' <br />/ter--------�\ <br />I� �I <br />I8'X20' <br />LOUVER _ = <br />I\ I,-6, <br />LOUVER DTL. <br />B SCALE.Il1 . 1�_0I/2. I'-0' <br />AIt0NIT■CTt <br />Gro�uo <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33834 <br />PH: 613-8862628 <br />FAX: 813406-2802 <br />sec <br />avaDIV. ae )LOT <br />SILVERADO <br />LOT #6 <br />BLK #14 <br />PROJECT* <br />03719.000-06141 <br />1[ODEL. <br />2795—B <br />GARAGE 81WMG: <br />RIGHT <br />PAGE: <br />FRONT & REAR <br />ELEVATION "B" <br />150 MPH Ey. B <br />NOV <br />D AW.j. 10/30/20 <br />SICAL M: 1/4"=1'-0" <br />a*== <br />A2 B <br />