7104 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7104 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:09:50 PM
Creation date
2/19/2025 12:15:34 PM
Metadata
Fields
Template:
Building Plans
Street #
7104
Location
Silverado Ranch Blvd
Contractor
DR Horton
Building Plans - Permit #
None
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SHALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS 514A-L. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2OTT) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2On) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED N ACCORDANCE TO FBC 6TH EDITION <br />(201T) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOUTERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2OT1) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIR -/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. R=COM'M'9ENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECa DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />O O <br />EXTERIOR WALL <br />PLENUM*PEXTEFRiOR <br />AIR RETURN <br />ON AND LIQUID <br />AIR SUPPLYGERANT <br />LINES <br />AIR HANDLER <br />WALL <br />VC CONDENSATE DRAIN LINE <br />EVAP.TRAYLEEVE <br />TO LINES BELOW SLAB <br />REFRIGERANT LINES t0 <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2O1T) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.YL OPT[/SPEC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE• RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRI AIR GRILL <br />SECURE STRAP TO CONIC. CONDENSER <br />W/ (2)-3/I6'X2' TAPCONS UNIT SR-IPSON US ROLL STRAP <br />OR EQUAL <br />4'CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />f8x1 1/4' SHt. MtL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAN CCND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-81/15, GONG. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />OFLOOR SLAB CLEAN -OUT (TYPN NEXT. GROUND CLEAN -OUT (TY <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />SCALE: 114 = I'-0' <br />■ <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />wwwabdesigngroup.mm <br />AA #: 0003325 <br />114 <br />1 <br />G <br />� <br />a <br />u <br />POOR. a rcT <br />SILVERADO <br />LOT #22 <br />BLK. #7 <br />PROJWT# <br />04128.002-22071 <br />KODEL• <br />4EBB <br />"1828-CALI" <br />CFARA Z BVfnM: <br />RIGHT <br />PAGE: <br />MECHANj <br />PLAN <br />%150 MPH E <br />f` i lam` � - d �� 1"�:• di -1�1 <br />Dw� 08/03/19 <br />SCALE: 1/4"=1'-0" <br />SI�ET <br />MI <br />