My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7104 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7104 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:15:52 PM
Creation date
2/19/2025 11:23:48 AM
Metadata
Fields
Template:
Building Plans
Street #
7104
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1533
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF -ADHERING <br />hEMDRANE FLASHING OVER <br />TOP, 61DE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SE�'!`4'e OF PLASHING TO BE. <br />L BOTTOM- 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />1 . <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />-.,X- <br />:• <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />t <br />JOINTS AND INTERSECTIONS <br />' I <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALLLSIDEE&V CAULKING a JOINT <br />ALLAAND <br />I <br />I <br />PER SECTION R70 . <br />Exterior Ia1MnG and PWsterin0 <br />BACKER ROD <br />I <br />Exterior use of pordand cement plaster <br />shall comply with the application <br />- <br />requirements of ASTM C 926-18b. <br />X, <br />1 <br />Installation of exterior lathing and framing <br />1 <br />shall comply with ASTM C 1063-19a, <br />i `• <br />orASTM 1787. <br />WRB LAYER h, <br />' . �':: <br />OTUC 0 WRAP <br />I <br />HOODED VENT <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRD LAYER Q, FORTIFIDER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />( FRAME) <br />CLA <br />SHEATHING <br />ER, FORTIFISER <br />ING PAPER <br />WDOD <br />CON6TUCTION <br />_METAL LATH <br />a' Cm VINYL CA6WQ DEAD <br />6' RAISED BAND <br />a�'EE� �SCRSED L <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z PLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK. <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER a2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/Ifo' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R'1031.1 / ASTM C-841-14a, MIN. 2B L59. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />NVVENT <br />IS' SELF ADHESIVE <br />WOOD CONSTRUCTION <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />WRB LAYER 01, <br />UNIT <br />STUCCO WRAP <br />PREMANUF. DRYER <br />CAP (SET IN <br />CONT. SEALANT) <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />TOP 4 SIDES <br />�' THICK, 3 COAT CEMENT <br />WOOD SHEATHING <br />PLASTER <br />LAYER h, <br />54 <br />STUCCO WRAP <br />6B DRYER <br />VENT (BLOCK) <br />I ' TO Ys' MI WALL <br />BUILDING PAPERRTIFIBER <br />' METAL LATH <br />CON6T1!lCTION <br />..�-�M 6THBe ADD <br />6' SELF-ADHESIVE <br />FASTEN TO WOOD STRUCTURAL <br />FLASHING <br />a' ahu <br />MEMBER • T' Or— MAX <br />15UILDNG PAPER <br />OVER <br />WOOD FRAMED <br />8' To 1j MPS-"�L <br />ur1Ee+� eeRaED <br />FLASH.CIUi— <br />— — — <br />WALL <br />HORIZONTAL WEEP SCREED <br />PIPE <br />(FRAME TO FRAME) <br />6' WIDE STRIP SELF <br />ADHESIVE PLA04M CLEANI�UIALL <br />MASONRI' DEPORE APPLYM? <br />FNNI MASONRY <br />FLASHING.I— <br />SELF (INOT L <br />(INSTALPER <br />WEEP SCREED <br />MA". SPECBUILDING <br />®HORIZONTAL <br />(FRAME <br />TO BLOCK) <br />PAPE <br />UNDER 'QUICK FLASH' <br />S' <br />A VENT PENETRATION <br />SCALE: N.T.B. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />IT THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />UIRB LAYER 01, <br />STUCCO WRAP <br />CUT SUCH THAT 9 <br />APPLY 60 MN <br />SEM51RANE <br />NO MEMBRANE <br />GRADE '0' FELT <br />FLASHING, <br />MEMBRANE FLASHINCs <br />_ <br />ENTERS BOX, <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRIB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP *3 <br />STEP *14 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />STEP 05 STEP #& <br />OELECTRICAL RECEPTACLE <br />LATH <br />N C N I T 1 C T s <br />6 <br />Grouolgn <br />.... LONGZ; , FL 32750 -- <br />PH: 407-714-6078 <br />FAX: 407-774-4078 <br />www.abdeWgngroup.com <br />AA M: 0003325 J <br />IF DRIFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886.2628 <br />FAX: 813-SM2802 <br />D 02/03/21 <br />81 1/4"=1'-0- <br />st�s: r <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.