My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7109 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7109 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:22:09 PM
Creation date
2/19/2025 12:20:12 PM
Metadata
Fields
Template:
Building Plans
Street #
7109
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22282
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LEW THEN 14-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER MC 6TH EDITION (201) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS 1 AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN V FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER PSC 6TH EDITION (201) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFOR-IS SHALL BE CONSTRUCTED IN ACCORDANCE TO PBC 6114 EDITION <br />f2VM) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PBC 6TH EDITION (201) MECHANICAL. CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND PBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECN DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />CEILING EXHAUST FAN <br />RL <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />L9 <br />PA66-THRL AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PAN* W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/16'X2' TAPCONB WIT <br />SIMPSON US ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECUSTRAP TO UNIT W/ <br />RE <br />-SXI 1/4' SHT. MTL. SCREWS <br />(2) <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER____EXTERIOR <br />y <br />CONNECTION <br />TO PAD <br />WALL <br />y <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER 44EAD 0 Yl' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />F <br />PVC 6LEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAM, AS PER <br />F5CR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION Mn2A <br />HVAC <br />DRAINS <br />Lo <br />SCORIATED NICKEL <br />FL. PL. <br />� <br />FM. FLOOR <br />OR WALL <br />COW CIO. <br />PLUGBRONZE <br />CA. PLUG <br />� <br />� SEE SPEC. <br />BRASS PLUG <br />�'�--FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 0240-K JOSAM 560M <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTUSPEC <br />FLOOR SLAB CLEAN -OUT (TYPN <br />FIN. GRADE <br />OR PAVING <br />11-6•xr CONc. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />1 EXT. GROUND CLEAN -OUT (TYPN ) <br />MECHANICAL PLAN <br />SCALE: 1/4 - I'-0' <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX:407.774-4078 <br />www.abdaslgngroup.00m <br />AA 5: 0003325 <br />C <br />• <br />V <br />W <br />D <br />D <br />a <br />BUBDXV. lle LOTS <br />SILVERADO <br />LOT #11 <br />BLK. #18 <br />[Puon=T# <br />04128.002-11181 <br />MOD2Ellu <br />4EBB <br />"1828-CALL" <br />GAltA*Z OWINOt <br />LEFT <br />I1PAGUC: <br />MECHANICAL <br />PLAN <br />50 MPH EXP. B <br />DAM 10/09/19 <br />QCAIM 1/4"=1'-0" <br />DIET <br />M1 <br />00 <br />