My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7113 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7113 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:34:57 PM
Creation date
2/19/2025 11:26:48 AM
Metadata
Fields
Template:
Building Plans
Street #
7113
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1532
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL V SELF-ADHERMG <br />MEMBRANEFLASHMG OVER <br />TOP, SIDE($) AND BOTTOM <br />FLANGES O'NON-MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO DE, <br />L RO'tTOM. 2_ SIDES. 9_ tOP <br />VENT CAP IS TO BE SET IN BED <br />..,:.k.. <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO DE <br />TOOLED 60 AS TO DEFLECT <br />1 <br />WATER AWAY FROM JONTB. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />F <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />� LAIdL BNGD�S, Yi CAULKING • JOINT <br />A <br />I <br />I <br />PER SECTION R D3. <br />EXtalor lathing eTM daetsrYw <br />BACKER ROD <br />I I <br />Exterior use of Portland cement plaster <br />shah comply with the application <br />requirements of ASTM C 926-18b. <br />,X. <br />K: <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />LLIFB LAYER 01,F <br />,.x�, <br />STUCCO <br />HOODED VENT <br />.'X. <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WPM LAYER 4, POWPI15ER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />:1 SHEATHING <br />LAYER 'I, <br />CO WRAP <br />LAYER 4, FOR'TIFIBER <br />WOOD — <br />CCNSTUCTICN <br />-METAL LATH <br />a' OM VINYL CASING DEAD <br />6' RAISED BAND <br />V TO Jr Men-n—,_ <br />WEER &CREED <br />6' WIDE STRIP SELF <br />ADHESIVE FLANS, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 62 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2B LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT* <br />TOP ! SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDMG PAPER <br />OVER 'QUICK <br />FLA6H' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE - <br />FLASWING INSTALL <br />PER MANUF. SPECS.) <br />15UILDNG PAPEI <br />UNDER 'QUICK FLAS <br />AIVENT PENETRATION <br />ri SCALE: N.T.B. <br />ELEC. METEI <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL FOR TO <br />ELEC. METER INSTALLATION <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />LURE, LAYER 01, <br />STUCCO WRAP <br />WRB LAYER n, FORTIF15ER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />36' TO Ni' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />-L � I WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (U LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC, <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />��`")ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />LURE, LAYER 01, <br />STUCCO WRAP <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT - <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE '0' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />LAYER 01, <br />STUCCO WRAP <br />LAYER tl, FORTIFIDER <br />BUILDING PAPER <br />METAL LATH <br />wow CONSTRUCTION-FTM�18 • OOOODD <br />FASTEN TO WOOD STRUCTURAL <br />k MEMBER • T Or— MAX <br />a' CM <br />7f,• To1f' nID.wALL <br />wEEP er�aD <br />6• WIDE &TRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYM <br />V FINISH • MALiON11Y <br />® HORIZONTAL WEEP SCREED <br />FRAME TO BLOCK) <br />6• <br />WRB LAYER N, <br />STUCCO WRAP <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />STEP S STEP #& <br />n9 ELECTRICAL RECEPTACLE <br />LATH <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078. <br />FAX- 407-7744078 <br />www.abdosigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 81341188-2828 <br />FAX: 813-886-2802 <br />aUBDTV. & LOT <br />SILVERADO <br />LOT #7 <br />BLK #14 <br />PROJECT/F <br />03719,000-07 <br />mop72 95-B <br />Gw>ttwGIC BWMG: <br />LEFT <br />PAGE <br />WALL <br />ASSEMBLY <br />DET S <br />150 PH 1EXP. B <br />
The URL can be used to link to this page
Your browser does not support the video tag.