Laserfiche WebLink
A41) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9) 1Od x 1 }" NAILS TO TRUSS <br />B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12)16d x 1 J" NAILS TO TRUSS <br />DEL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C-(1) SIMPSON LGT2 GIRDER TIEDOWN WITH <br />(16) 1 Od x 3 }" NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12)16d x 3 }" NAILS TO GIRDER <br />1x2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3)16d <br />GALV. COMMON NAILS. <br />1x2 SECURED W/ 10d <br />GALV. COMMON NAILS <br />12" O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP #2 2" x 4", <br />6", 8" x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS, <br />ENGINEERED WOOD <br />TRUSSES 0 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT = U: 1810 LBS, L:T70 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U:2365 LBS, 1_:1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) <br />1A 1B 1C TYPICAL TRUSS/ <br />GIRDER CONNECTOR(S) <br />3/4" T 8 G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG FLOOR TRUSS <br />5/8" GYPSUM BOARD OR 1/7' HIGH <br />STRENGTH CLG. BOARD <br />SECURE TRUSS TO TOP PLATE wl (2) <br />16d TOENAILS <br />DOUBLE TOP PLATE <br />ENGINEERED WOOD TRU <br />® 24" O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETA16 <br />TRUSS ANCHOR W ITH <br />(9)10d x 1 i" NAILS TO <br />GIRDER. PROVIDE 5" <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: APT SYP #22"x4", <br />6", 8" x 4'-0" MAY BE ADDED <br />W/ 1 Od NAILS, 2 ROWS, 3" <br />OIC TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />L-A41) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN <br />WITH (4) r x 5" TITEN HD TO CMU AND (12) SOS <br />}" x 2 j' TO GIRDER <br />B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH <br />1x2, 2x WOOD FASCIA (2) in x W TITEN HD TO CMU AND (18) SOS }" x <br />SEE ARCHITECTURAL 3" TO GIRDER <br />2x SECURED W/ (3)16d C42) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />GALV. COMMON NAILS. (2) j" x 5*TITEN HD TO CMU AND (18) SOS }' x 3' <br />Ix2 SECURED W/ 1Od MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN) <br />EA <br />GALV. COMMON NAILS BEAM SEE SCHEDULE ENSURE THAT CELLS ARE GROUTED <br />12" O/C SOLID, 8' EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT = 4725 LSS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) <br />2A 2B 2C TYPICAL ROOF <br />GIRDER CONNECTOR(S) <br />LSTAI2 20 GAUGE <br />W/ 10dxtn HOG NAILS <br />@ EACH END. TOTAL OF 10 <br />FLOOR <br />GIRDER <br />1TT4 W/ 5I8" A.B. WITH <br />AIN. 7" EMBEDMENT <br />TO SLAB 8 (18)16d x <br />2x4 OR 2x6 WOOD BEARING 2-in" NAILS TO POST., <br />WALL W/ SYP No 2 STUDS SEE POST TO SIT DIRECTLY <br />PLANS FOR SPACING, SINGLE ON SLAB <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />1/2" GYP. WL. BD. <br />.a.• 9 i.. .�. <br />%_'�GIRDER/WOOD POST CONNECTIONS <br />J SCALE: 3/4'=1'-0" <br />,/�FLOOR TRUSS CONNECTION @ L.B.W. <br />* SCALE:314"=V-0" (NO UPLIFT) <br />OUTER 9/3 OF <br />SPAN ONLY <br />BTM. - <br />PLATE <br />DEPTH 1/4'D <br />-HOLE EDGE >5/8" <br />-HOLE DIAMETER <br />< 2/5"D SGL. STUD <br />HOLE EDGE >5/8" <br />HOLE DIAMETER <br />< 3/5"D DBL. STUD <br />STUD NOTCHING <br />AND BORING LIMITS <br />8 scALE:11n°=r-0scALE:11n"=r-0" <br />A-SIMPSON HUS28 G < 1200 LBS, U < 1280 LBS W/ (1) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (8) 16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4- SIMPSON TITEN BOLTIJ-BOLT, 5" MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (10)16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G < 2400 LBS, U < 1810 LBS WI (2) 3/4" SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV, COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS WI (4) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4" SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36)16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: 3l4""=1'-0-0" <br /># 1100 UPLIFT SIMPSON - <br />HTSM20 W/1010d TO <br />TRUSS AND (4)1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1000 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/10 1 Od TO <br />TRUSS AND (4)1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN. <br />2" COVER 8 2" APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />3 SCALE: 314"=1'-0" <br />6'-0" MAX (W/1X4) <br />OR 10'-0" MAX (WI2X4) <br />1 x4 DIAGONAL <br />BTM.CHORD <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />Ix4 BTM. CHORD BRACING 6-0" O/C —/ `-END WALL OR OTHER <br />MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF <br />10'4- O/C MAXSECURED W/ (2)10d DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD <br />INTERSECTION TYP. BTM. CHORD BRACING <br />6 SCALE: 3/4"=1'-0" <br />5'EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE <br />C� H� <br />SCHEDULE MIN PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />5 112" MIN. EMBED. (TYP) <br />SEE LEDGER SCHEDULE d <br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, 8" ALL AROUND <br />BOLT. <br />Z <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />0° <br />LAP A MIN OF 4'-0". <br />3. ALL BOLTS TO HAVE WASHERS <br />Z <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />m <br />CLOSER THAN 6' O/C. <br />5. IN LIEU OF HILTI PAPS SIMPSON TITEN 1/4" <br />(2)_ PT <br />DIA, x 3" MASONRY SCREWS MAY BE USED, <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLTSIZE <br />FEDGE&PAM <br />CBRRALSPACING <br />A <br />DOUBLE 2x8 <br />in" <br />11.01 <br />16" O/C <br />B <br />DOUBLE 2x8 <br />3/4" <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 2x10 <br />in" <br />8"" <br />16"O/C <br />D <br />DOUBLE 2x10 <br />3/4" <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 2xl0 <br />3/4" <br />6" O/C <br />16" O/C <br />F <br />DOUBLE 2,12 <br />3/4" <br />8" on <br />12" O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 314"=V-0" <br />(2) 2X4 No.2 SYP DIAG. <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3)12d 0 EA <br />TRUSSES WHERE <br />TRUSS (DIAG. BRACE TO <br />X-BRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4'-0" O.C. (AT SHEATHING <br />0'-0" TO 30'-0' (1) -X" BRACE <br />SEAMS) <br />30'-1" TO 60'-0 (3) X' BRACE <br />SECURE 2x8 PT. PLATE <br />(1) "X" BRACE 0 CENTER <br />TO BLK WI 1n" DIA. <br />(2) "X" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/ 2" <br />FROM CENTER TO END, <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 6" <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 32" OC <br />MAX. <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />P,T. PLATE W/ 12d'a 8" <br />STIFFBACK (AS PER <br />O.C. MAX <br />TRUSS ENG) <br />CONT. 2x4 SECURED Wl <br />(2)10d's @ EACH TRUSS <br />TO BE INSTALLED Q <br />10'-0" O.C. MAX. <br />SEE SCHEDULE FOR <br />BOND BEAM RED. <br />BLOCK WALL W/ GABLE END <br />PRE-ENGD TRUSS SCALE: 314"=1'-0" <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Ft AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED, A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 <br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO FI AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE: 3/4"=1'-a' <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO,FL32750 <br />PH: 407-774 6078 <br />FAX: 407-774,4078 <br />www.abdoslgngroup•com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: SISSM-2628 <br />FAX: 8134388.2802 <br />BUDDIV de LOT: <br />SILVERADO <br />LOT ##18 <br />BLK ##13 <br />PROJECT/4 <br />mopmm u <br />2795-D <br />GARAGZ SVnNG: <br />LEFT <br />PAGE: <br />DETAILS <br />V.150AWH EA B <br />E <br />D W 01/30. <br />BCALM- 1/4"=1'—O" <br />8*1z= <br />s3.1A <br />