HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL DE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FAD 4 MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />9. ALL FLEX DUCTS SHALL BE APPROVED UL I& CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />CUTLET, OR SANITARY SEWER VENT OUTLET <br />D. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC TTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 'ITN EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />1, ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND MC NTH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY OIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TR INK <br />BALANCING DAMPER OR ODD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />MECHANICAL PLAN <br />SCALE: 1/4' " 1'-0- <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.G OPTI/SPEC <br />1 FL00R SLAB CLEAN -OUT (TYPN) <br />COUNTERSINK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT TY�PI'M0 <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3A6'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />VXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN CONO. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />>ALL <br />ATTICCEILING <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBGR TTH EDITION (2020) <br />MECHANICAL BLOC. CODE <br />SECTION 30.12.4 <br />HVAC <br />DRAINS <br />A A C N I T! C T i <br />Grou��. <br />3.443. N. NVRALU KtAUM GLYV. <br />LONGWOOD,FL32750 <br />PH: 407-774.6078 <br />FAX 407-7744078 <br />www.abdaslgngroup.com <br />L AA M: 0003325 J <br />IIINIII <br />etMDIV. S. LOT <br />SILVERADO <br />LOT #8 <br />BLK. #14 <br />PROJECT <br />03719.00t -08141 <br />MODaia <br />"2558-HAWTHORNS" <br />GARAGE 8M►MO: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH B <br />