Laserfiche WebLink
GABLE -END' <br />ROOF WIND DESIGN PRESSURES <br />NET(GROSS) ASCETIO <br />ZONE 1 = 8.97 PSF (19.97) <br />ZONE 2 =17.98 PSF (27.98) <br />ZONES = 3353 PSF (43.53) <br />"A"e 4'-O" END ZONE DISTANCE <br />BASIC VIAND SPEED: 150 MPH <br />WIND EXPOSURE: "6" <br />RISK CATAGORY: 11 <br />APPLICABLE INTERNAL <br />PRESSURE COEFFICIENT +- 0.18 <br />ROOF 04 1140AGIM <br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" <br />O.S.B. OR 1/2" COX EXT. PLYWOOD, FOR <br />CEMENTITIOUS TILE AND METAL ROOFING, USE <br />MIN. 618 COX EXT. PLYWOOD, WTH 8d RING <br />SHANK GUN NAILS AT 4" O.C. AT SUPPORTED <br />PANEL EDGES AND 8d RING SHANK GUN MILS <br />AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE <br />DETAIL <br />ROOF SHEATHING TO GABLE END FRAME USE <br />8d GUN NAILS ® 4" O.C. EDGEWISE 2x4 <br />BLOCKING ALL PANEL JOINTS W IN V OF GABLE <br />END. <br />ROOF/ WALU FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL SCHEDULE <br />SIZE <br />TYPE <br />MIN. LENGTH <br />MIN. DIA <br />SHANK <br />TENSILE STR. <br />SHANK <br />8d <br />RING SHANK <br />21/Z' <br />0.1201 <br />In,= <br />RING <br />SCREW SHANK <br />(i8-20 RINGS <br />PER INCH) <br />Sd <br />SCREW SHANK <br />2 1/2" <br />0.120' <br />PNEUMATIC <br />SCREW -NAILS <br />1. NAIL SIZE PER ASTM F1684 <br />2. INTERNATIONAL STAPE, NAIL & TOOL <br />ASSOCIATION (ISANTA) ESR-1539 <br />EXTERIOR SHGILTHIND <br />USE 1/2" COX OR 7/1W O.S.B. PLY WITH Sd RING <br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES <br />AND 8d RING SHANK GUN WAILS 4" O.C. TOP & <br />BOTTOM PANEL AND 8d RING SHANK GUN <br />NAILS AT 8" O.C. AT INTERMEDIATE SUPPORTS <br />OR 7116" ZIP SHEATHING SYSTEM (INSTALLED <br />PER MANUF. SPECS.) SEE DETAIL. <br />8d RING SHANK GUN NAILS 0 4" O.C. <br />TOP & BOTTOM EDGES <br />J <br />w . <br />z9 <br />Y Z <br />2 <br />rnO <br />Z <br />a Y <br />z zj <br />j 1S <br />1 <br />'`J <br />C7 N <br />Z W LU <br />Q <br />S U <br />N N <br />Z m <br />TOP CORD BLOCKING AT 4' <br />O.C. MAX. IN FIRST2FRAMING <br />SPACES AT EACH END. <br />RAFTER OR TRUSS <br />ROOF SHEATHING <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL BRACING <br />FOR GABLE END FRAMWO <br />8d RING SHANK GUN NAILS <br />B"O.C. IN FIELD. <br />TYP EXT. SHEATHING ATTACHMENT FOR ROOF SHEATHING (O.S.B. <br />TO BE STRUCTURAL GRADE <br />Bd RING SHANK GUN NAILS a 12' O.C. IN <br />FIELD or Sd x 2 12" SCREW SHANK <br />PNEUMATIC SCREW -NAILS M 170. <br />FIELD J\ <br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />GENERAL NOTES: <br />ALL AGGREGATE USED W CONCRETE SAL CONFORM TO ASTM C33. MXIMUM AGGREGATE SIZE SHALL BE Mr. <br />STRUCTURAL DRAWINGS SHALL BE USED IN CORI UNCTION WTH JOB SPECIFICATIONS AND <br />Wow: <br />ARCH MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT <br />PROVIDE B%AIR ENTRAINED CONCRETEF)0'09ED TO EMTHORNEATHBR <br />NOIS BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. <br />ARCHITECTURAL DRAW NGS FOR SLEEVES, DEPMESS IONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAW NOS. APPU CABLE BUILDING CODE STANDARDS: FBCR 2017, 6N EDITION <br />ALL EXPOS®EDGES Of CONCRETE ARE TO BE CFW/FHtED 3l/'. <br />ALL WOOD FOR BEAMS, BEAM W. WALLS, SOLE PLATES, TOP PLATES, BRAONG, LEDGERS, BLOCKING, <br />ACI 318-14, BUILDING CODE REQUIREMENTS <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO.2 OR BETTER. Po = 1100 PSI ANDA MODULUS OF <br />FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5.13 AISI SPECIFICATION FOR THE DESIGN OF <br />PROVIDE S-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UDERALL &ABSONGPALM WHEM INDICATED ON <br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPECIFICATIONS <br />DRANANGS.SEAMS LAPPED B INCHES AND SFALEDWTH ADRESVETAPE <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NONSTRUCTURAL USES <br />SHALL BERATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />FORMWORK <br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />REASON SHALL BE RATED TO RETENTION LEVELS OFO.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOUM. <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WTHACI 347, <br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBERTHAT <br />'RECOMMENDED PRACTICE FOR CONCRETE FORMWORK. <br />CONTAINS MORE THAN W OF HEARTWOOD. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD, DO NOT SCALE THE <br />DRAW N GS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />EXCLUSIONS FROM THIM PLANS: <br />MINIMUM NAILING PER PBOR 2017, 61h EDITION. SEE NAILING SCHEDULE ON PLANS. <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />OF THE WORK. <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRl1CTURAL.DEPENDING <br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAYBE REQUIRED BUT ARE BY OTHERS. <br />SYP #2. <br />THE STRUCTURE 19 DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WTH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />SEOUENOES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />WELDED WIRE MESH' <br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES. <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE4)OWNS. <br />WELDED W RE MESH, SHALL BE ASTM A185, GRADE 65 AND BE PLACED IN ACCORDANCE WTH THE ACI <br />WOOD TRUSSES: <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />TYPICAL DETAILS. MINMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. NNE MESH FOR SLABS SHALL BE <br />SUPPORTED WTH T CHAIRS SPACED T-O' OC, EACHWAY. <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE 'NATIONAL DESIGN SPEgFICATION3 FOR <br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE WPA. TRUSS DESIGNS SHALL BE SIGNEDAND <br />REQUIREMENTS AND SLABdN-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR <br />TO WORK PERFORMED A SHALL NOTIFY THE ARCHITECT IF ANYDISCREPANCIES A FO . <br />MD RE 11NI) <br />DESIGN LOADS: <br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf <br />20 pef TOP CHORD ­cueent <br />10 psf BTM CHORD-naancu reM <br />DEADLOAD DEAD LOAD <br />15 psf TOP CHORD 20 PST TOP CHORD <br />(7 psf W/ ASPHALT SHINGLES) (10 pef W/ No GYPCRETE) <br />10 pAf BTM CHORD 5 psf BTM CHORD <br />DEAD LOAD TO RESIST W ND UPLIFT: i Opef <br />BALCONY LIVE LOAD 60 PO <br />STAIRS LIVE LOAD 40 PST <br />WNO DEAD LOAD SPEED=IN MPH 3-SECOND GUST <br />(ASCE 7-10 (FBC R2017) EXPOSURE B, RISK CATEGORY II) <br />LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WTH LIMITED <br />STORAGE: 20psf, HABITABLE ATTICS AND ATTICS SERVED WTH FIXED STAIRS: 30paf, BALCONIES (EXTERIOR) <br />AND DECKS: 40psf, GUARDS AND HANDRAILS: 200pef, GUARD IN -FILL COMPONENTS: 50paf, PASSENGER <br />VEHICLE GARAGES: 50pef, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: <br />40psf <br />SHOP DRAWING REVIEW: <br />SHOP DRAWNGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OFTFE CONTRACTOR TO VERIFY <br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. <br />DRAWINGS SUBMITTED WTHOUT REVIEW WLL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER IN ALL INSTANCES, THE CONTRACT <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAW NGS CHECKED, UNLESS OTHERWISE SPECIFIED IN <br />WRITING BY THE ARCHITECT. <br />FOUNDATION SITE PREPARATION: <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PST, FOOTING <br />EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 9594 OF THE <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WTH ASTM D7557. TREAT ALL <br />SOIL FOR TERMITE PROTECTION. <br />l - <br />RESAR SHALL BE ASTM A615 GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM-15 <br />GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED INACCORDANCE <br />W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS, <br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION, HORIZONTAL <br />AND VERTICAL SANS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS <br />REVIEW. <br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25' #6 BAR - 36' <br />#5 BAR - 30' #7 BAR - 42" <br />PROVIDE 3Wx 3W CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />FOR ADDITIONAL INFORMATION, <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WTH <br />MINIMUM 10 INCH HOOKS OR SENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE <br />WALL. <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL <br />INTO INTERSECTING WALLS AND HOOK AT ENDS, STAGGER SPLICES WHEREVER POSSIBLE. <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />WITHOUT THE APPROVAL OF THE ENGINEER. <br />MA"Rr. <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WTH ALL REOUREMENTS OF THE <br />"SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES). AS <br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. <br />ALL BLOCK WALLS SHALL BE NA -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />MANUFACTURED IN CONFORMANCE WTH ASTM C-90, GRADE fm = 1500 PSI. BLOCK SHALL BE PLACED USING <br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WTH <br />ASTM G476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM S78" <br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF W TO 10". USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT, MORTAR SWILL BE <br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM G270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />SHALL BE 3/9" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />CELLS TO BE FILLED. <br />THE OWNER$HALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />FILL CMU CELLS SOLID W TH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANDIOR VERTICAL <br />REINFORCING. <br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL <br />STRU(A•TURAL STEELBE <br />MADE BY THE OEO-TECH. ENGINEER. <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WTH THE <br />CONCRETE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION STRUCTURAL STEEL SHALL BE ASTM <br />A36, Fy - 36 W FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B, <br />Fy= 46 WL STRUCTURAL PIPE SHALL BE ASTM53, GRADE B, TYPE E OR 8, Fy -35 ksi. TUBE AND PIPE <br />2,500 P91 REGULAR MIGHT FOR FOOTINGS, AND SUB-0NGRADE <br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE 8LA& <br />CONTRACTOR SHALL SUBMIT PROPOSED MX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL <br />CONCRETE PLACEMENT. CONCRETE SLUMP SWA NOT EXCEED 5'N- PRIOR TO THE ADDITION OF PLASTICIZER <br />BE TIGHER OLTS SHWLLBE A3TMA3WTH THE TS WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL <br />BE TIGHTENED IN ACCORDANCE WTH THETUiN-OFF-THESAIT METHOD. <br />CONCRETE SHALL COMPLY WITH ALL THE REWIRBAENTS OF ACI 301 AND ASTM C44 OR MEASURING, MYIND, TRANSPORTING, ETC. ALL ANCHOR BOLTS SHALL BE GALVAN ZED STEEL. J43OLTS ARE TO BE STEEL. <br />CONCRETE TICKETS SHKL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MANMIM TIME ALLOWED FROM MEN WATER IS <br />ADDED TO THE MX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MNUTES. IF FOR ANY REASON THERE IS <br />DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE <br />RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NON <br />COMPLIANCE WTHTHEPBJIE. <br />REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS <br />A 3' FOR CONCRETE CAST AGAINST AND PERMANENTLY EPOSEDTO EARTH(FOUDATKNS) <br />a FOR CONCRETE EXPOSED TO EARTH ANDORWEATHER <br />1.1/7FOR #5 AND SMALLER <br />2' FOR #8 AND LARGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />314. FOR SLABS, WALLS AND JOISTS <br />14I1' FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TES, STIRRUPS <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -UPPED GALVANIZED. <br />DESIGN FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI.14, "DESIGN NATIONAL <br />STANDARDS FOR METALPLATECONNECTEDM OOD TRUSS CONSTRUCTION:, AND 'TPINVTCA SCSI I" <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTH ANSI A58.1-1982. <br />HURRICANE STRAPS SHALL BE INSTALLED ACCORD NO TO MANUFACTURERS INSTRUCTIONS. <br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAW NGS FOR ALTERNATE CONNECTION DETAILS AT <br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS TWAT <br />AFFECT THE STRUCTURAL BEARING AS GILLED OUT ON THESE PLANS SHALL BE NOTIREDTO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />PROVIDE ENGINEERED SHOP DRAW NGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />PLAN SHOW NG COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />LICENSED PROFESSIONAL ENGINEER <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THS PLAN SHALL SUPERCEDE THOSE <br />OF THE DELEGATED TRUSS ENGINEER. W ND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT <br />AND CLADDING W ND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "USP STRUCTURAL <br />CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS <br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE <br />LATEST CATALOG. <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK FASTENERS <br />FASTENER <br />APP -r- <br />SIT£ <br />1. <br />SPACING <br />RE- <br />APPLICFnON <br />311E <br />TYPE <br />SPACIAL <br />REWRI® <br />1,2 PTRIPRMG ICI <br />CASE HWDB-IOUCOIL <br />8'QC <br />OMAOE DOOR BIMA( <br />SEE DETNL <br />SEE DETAA <br />EEEDETNL <br />9EE.E-L <br />MASIXJRY ICONC <br />NNLI I?LONO <br />To.-- <br />N..IXT. DOORS <br />PT, SEE -TES <br />-EIMRO@1W COD. <br />NNL1I LONG. <br />B`OC <br />sTA00ERW <br />WMDOWIDDOR/FABIBI® <br />INTO MAg)MYIWNC. <br />GAR/dE WOR BUCIt <br />TO N480MY/lY)NC. <br />SEE DETNL <br />SEE DE <br />SEE DE- <br />SEEDENL <br />vnN�w giac <br />CASE H4RDENEDC- <br />9"OIC <br />WINDOWAIOOR/FAe . <br />NErAL ST-. <br />CONTACT THIS ENGINEER <br />FOR SPACING <br />1>t PT. SEENOTES <br />-11 I/Y LOAD. <br />STAGGERED <br />INTO r.41SONRwmNc. <br />MASONRY c- <br />REQUIREMENTS <br />ExT.gwNO DOOR <br />-I CODA <br />I I YY'EMBW.B"ENO. <br />NCNBFARIIq YA00 <br />t2` ElSNJgON 1"EIUBED YFND <br />BDCxh PT,SEENDTE. <br />N119nS <br />OWAg1ER <br />FASTNER <br />1YC� <br />DUST.. I I lY WOELIef <br />-TO CONC.8LA9 <br />WI WIDENER BOLT IA OC O'ST., 9`EDGE0.. <br />PfWMOOWIICX BFx21e- B`OC x`END. DUST.. 112 <br />PT"TO STEEL COL. SEE IyIIy� BTAGOERW EpOE DIET <br />NOTES <br />NOR <br />t. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURERS SPECS AND/OR NOA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. RAF SHALL BE HILTI XZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />6. W NDOW AND DOOR BUCKS SHALL BE AS W DE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. 1x MEMBERSARE NAILED AND <br />2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.8078 <br />FAX: 407-774.4078 <br />www.abdosoVoup.com <br />AA M: 0003325 <br />�p <br />W <br />a <br />Y <br />IV <br />O <br />yQj <br />df <br />Q <br />N <br />n! <br />O <br />Q <br />taa11 <br />ays0iv ae L07`. <br />SILVERADO <br />LOT #24 <br />BLK, #7 <br />PROJW' <br />04 001 4 7 <br />MODNIt <br />4EBB <br />"1828-CALI" <br />GAReAOa BWDM: <br />LEFT <br />PAOIQ: <br />DETAILS <br />150 MPH EXP. B <br />CALF: 1//4T1=11'-O" <br />a S 1V 1 <br />