GENERALNOTES
<br />1. ALL WORK DONE UNDER THIS CONTRACT $HALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR)
<br />61h EDITION, (2D17) AND IN CONJUNCTION WITH ASCE 7-10. ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED
<br />IN THESE DOCUMENTS ARE UNDER FBCR 6TH EDITION (20T7) UNO.
<br />2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR
<br />BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY
<br />THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE
<br />DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.21.2.
<br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK
<br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION
<br />OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK.
<br />THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE
<br />CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION ANDIOR
<br />FABRICATION OF THE WORK.
<br />S. THE ARCHITECTIENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES,
<br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES.
<br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR
<br />SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING
<br />CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED.
<br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS.
<br />8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECTIENGINEER.
<br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED.
<br />GARAM AND CARPORTS
<br />1. GARAGE DOOR
<br />A. ENGINEERED FOR MIN. WAND LOAD, LISTED ON COVER SHEET
<br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLER
<br />C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER
<br />2. AS PER SECTION R3025.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING
<br />PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED NTH
<br />SOU WOOD DOORS NOT LESS THAN 1318 INCHES IN THICKNESS, SOLID OR HONEYCOM3 CORE STEEL DOORS NOT LESS THAN
<br />13B INCHES THICK, OR 2D-MINUTE FIRE -RATED DOORS.
<br />3. AS PER SECTION R3025.2: DUCTS IN THE GARAGE AND DUCTS PENETRATINGTHE WALLS OR CEILINGS SEPARATING THE
<br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.28 GAGE (0.48 MM) SHEET STEEL V MN. RIGID
<br />ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE
<br />GARAGE.
<br />4. AS PER SECTION R3026 & TABLE R3026: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT
<br />LESS THAN %-INCH GYPSUM BOARD APPLIED TOTHE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE
<br />SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 /8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT.
<br />WHERE THE SEPARATION IS A FLOOR-CEIUNG ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALLALSO BE
<br />PROTECTED BY NOT LESS THAN %-INCH GYPSUM BOARD OR EQUIVALENT.
<br />S MINORK
<br />1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT).
<br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES,
<br />SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL
<br />DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL
<br />FINISH GRADES, PLANTING AND IRRIGATION.
<br />3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE
<br />ARCHITECT.
<br />4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN %THE HORIZONTAL
<br />DISTANCE FROM THE NEAREST EDGE OF THE FOOTING.
<br />5. ALL BACKF ILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8'
<br />LAYERS AND COMPACT TO 95%MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM 01557. THE
<br />BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS.
<br />6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED.
<br />7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE)
<br />8. EXCAVATIONS TO BE A MINIMUM OF 3-O" BEYOND NEW FOOTING LINE.
<br />9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE
<br />REQUIREMENTS.
<br />10. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, LINO. CONTRACTOR IS TO VERIFY THE
<br />ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL
<br />CODES HAVING JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES.
<br />11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP
<br />DRAWING.
<br />12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
<br />BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMENT PROTECTION
<br />LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE
<br />APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE
<br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT:
<br />'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES.
<br />TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
<br />AGRICULTURE AND CONSUMER SERVICES'
<br />TIER
<br />1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED
<br />HEREIN:
<br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL)
<br />B. NATIONAL FOREST PRODUCTS ASSOCIATION:
<br />I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
<br />C. SOUTHERN PINE INSPECTION BUREAU:
<br />I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
<br />D. TRUSS PLATE INSTITUTE:
<br />1. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-2014)
<br />E. APA- THEENGINEEREDWOODASSOCIATION:
<br />I. ENGINEERED WOOD CONSTRUCTION GUIDE
<br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
<br />2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
<br />3, MINIMUM NAILING PER CHAPTER 6. WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS.
<br />4, NOTCHING OR CUTTING OF FRAMNG MEMBERS SHALL COMPLY NTH CHAPTER 6- WALL CONSTRUCTION.
<br />5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEEROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEETSNI.
<br />6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE24"AND THE MINIMUM AREA SHALL BE8FT .SQ.
<br />PLUI
<br />1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL.
<br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS.
<br />3. CONDENSATION LINES SHALL BE MINIMUM PVC (SCHEDULE 40), INSULATED WITH'/.' AMAFLEX.
<br />4, SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH.
<br />5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE.
<br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES.
<br />7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2.
<br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903.
<br />9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE.
<br />10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P26032.
<br />E THUOR WALL COVEROlOi
<br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR
<br />THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R3012(2) AS MODIFIED BY TABLE
<br />R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE
<br />E TEIOR FNIB U
<br />1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, W THICK, OVER FRAMED WALLS
<br />APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS
<br />THAN 2 COATS,1/2' THICK, WHERE APPLIED OVER MASONRY OR CONCRETE.
<br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH
<br />ASTM-C926 & ASTWC1063.12EL
<br />3. LATH & ACCESORIES PER ASTM-C-1063-11A & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO:
<br />- ALL STUCCO CONTROL JOINTS - KICK -OUT DETAILS
<br />- 1"FLASHING - HORIZONTAL LATH AND PAPER DETAILS
<br />- PIPE PENETRATION DETAILS - VENT PENETRATION DETAILS
<br />- WEEP SCREED DETAILS - CONDUIT PENETRATION DETAILS
<br />- CASING BEAD DETAILS - DRIP EDGE DETAILS
<br />- CANTILEVER DRIP EDGE DETAILS - CORNER BEAD DETAILS
<br />- WINDOW CASING DETAILS - STUCCO TO SIDING TRANSITION DETAILS
<br />- WINDOW FLASHING DETAILS
<br />4, SHALL BE INSTALLED PER ASTM-CIO63-11AAND R703.7.
<br />UNDER STAIR PROTECTION:
<br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED
<br />ON THE ENCLOSED SIDE WITH 1/2' GYPSUM BOARD. R302.7.
<br />CONSTRUCTION OBSERVATION
<br />CONSTRUCTION OBSERVATION SERVICES /CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AS DESIGN GROUPS
<br />SERVICES FOR THIS PROJECT.
<br />IT IS UNDERSTOOD AND AGREED THAT AS DESIGN GROUPS SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW
<br />OF THE BUILDERS / CONTRACTORS PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WALL
<br />BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND
<br />FOR CONSTRUCTION OBSERVATION.
<br />EXTERIOR CELL MU
<br />1. EXTERIOR CEILING TO BE 12' GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING
<br />MEMBERS. THE 12" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1
<br />IN TYPE'W DRYWALL SCREWS AT 12' O.C. (PER MANUFACTURER'S SPECIFICATIONS) .
<br />CONTROL DATE: 07/23/19 (CM)
<br />1441 N. RONALD REAGAN BLVD.
<br />LONGWOOD, FL32750
<br />PH: 407-7748078
<br />FAX: 407-7744078 ,
<br />www.abdealgngroup.com
<br />AA N: 0003325
<br />P,
<br />z
<br />i
<br />Q
<br />rd
<br />44
<br />0
<br />i
<br />sum3rv. aft ImD,
<br />SILVERADO
<br />LOT #9
<br />BLK. #18
<br />PIIOJWT
<br />0 28.0 -0 1 1
<br />moDzx.1
<br />4EBB
<br />"1828-CALI"
<br />GAIIIIAGN STrINCk
<br />RIGHT
<br />PAGW..
<br />GENERAL
<br />NOTES
<br />150 MPH EXP. B
<br />I"PRINT "I
<br />DATJIk 10/09/19
<br />ECALM 1/4"=1'-O"
<br />simeZCT
<br />GN
<br />
|