HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS 614ALL 15E CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL ISE SEALED WITH GLASS PAIS s MASTIC. AND <br />INSTALLED AS PER PBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL ISE APPROVED UL Si CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN W FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED 6UPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, 6HOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALLS &BALL HAVE AN APPROVED FIRE OR PIRE/SMIOKE <br />DAMPER'S LOCATED AT CEILNG OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND POO 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />PANTECN DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />1010 <br />EXTERIOR WALL <br />PLENUM <br />T <br />b <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />1 <br />REFRIGERANT LINES <br />1 <br />AIR HANDLER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />d <br />PVC SLEEVE t0 LINES BELOW SLAB <br />T <br />REFRIGERANT LNES TO <br />PLATPOR I <br />RETURN <br />CONDENSING UNIT <br />TRAP ORAN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />VMECHANICAL <br />POOR 6TH EDITION (20f1) <br />BLDG. CODE <br />SECTION 3017A <br />HVAC <br />DRAINS <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LNE- RETURN TRUNK <br />I <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LNC44T <br />O/A <br />OUTSIDE AIR <br />® <br />THERMIOSTAT <br />ED <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC, CONDENSER <br />W/ (2)-3/I67O' TAPGONS UNIT SS'1PSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />*SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. P'L. � OR WALL C.O. PLUG <br />�—FITTING OR EXTENSION TO <br />601L OR WASTE AS <br />REQUIRED <br />INSIDE SSEERI S NICKEL BRA66 TOP <br />CAULK RVC, OPTVSPEC <br />vFL00R SLAB CLEAN -OUT (TYPN) <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-61X6' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (T�� <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE FPS. ELEVATION. <br />MECHANICAL PLAN <br />SCALE, V4 - I'-0' <br />:ml <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeskpVoup.com <br />AA M: 0003325 <br />W. <br />$ <br />m <br />w <br />ui <br />• <br />b <br />uuUA <br />Q <br />0 <br />Q <br />SLTMIV. At LOTS <br />IN <br />SILVERADO <br />LOT #9 <br />BLR #18 <br />F'ROJWT <br />4 28. -09181 <br />"ODAMA <br />4EBB <br />"1828-CALI" <br />OA.RAtim BU714M <br />RIGHT <br />PAGm: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />DAM 10/09/18 <br />eCALM 1/4-=1'—O" <br />021mmT <br />M1 <br />