Laserfiche WebLink
39'-8" <br />— <br />—FM-12X12 — — <br />—w <br />---FM•12X18------X <br />IN <br />I N <br />€0 a" CONC. F- <br />F <br />I <br />I� <br />$ � SLAB I� <br />w <br />I <br />ILL <br />y a *:3 1/2 1.q" LF-24X24 <br />10 <br />I • <br />1.1 <br />1 <br />I— 1 <br />FM 12X18 EXTEND <br />1.1 <br />1.1 <br />I <br />I <br />SLAB 1 1/2" <br />� <br />I• <br />I <br />0 <br />I <br />SLAB <br />N <br />F� <br />I <br />I <br />N <br />I <br />I <br />I <br />Ix <br />I• <br />I <br />I� <br />I <br />.I <br />I <br />I• <br />I <br />6", <br />1 V-8" <br />I <br />I 1 <br />4" PVC <br />I <br />I <br />Y <br />I <br />N I <br />*:"/2 <br />` <br />5 " <br />0 3'- <br />I <br />I <br />I <br />I <br />1 <br />EXTEND <br />SLAB 1 1/2" <br />2 <br />)4 CONC. �I m FM-12X18 <br />SLAB a X ' �, <br />I <br />-3 1/2 N al I <br />3,-4„ <br />I <br />L <br />b <br />2 <br />+-7 1/2 <br />1 <br />1 <br />1.1 <br />FM-12X18 1.1 J <br />FMC-12X18 <br />FM-12X18 <br />FMO.12X1 <br />4 <br />4 <br />1.1 <br />1.1 <br />3'-10' <br />7.8" <br />16'-0" <br />2'-8" <br />FOUNDATION PLAN <br />SCALE: 1/4" - 1'-0" <br />r4" CONIC. <br />SLAB <br />D+00 <br />TOP <br />SLAB <br />V� 3.6 *: <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +4-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION + 0'4% SEE SURVEY PLOT FOR NGVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7, COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11.01NDICATED #5 BAR, =INDICATES #6 BAR,MNDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90° <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6.36), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE *5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5.13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: Fm = <br />1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM 0476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND, <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER i OF SLAB SUPPORTED <br />3'-O" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 61h EDITION <br />SLAB SCHEDULE <br />SLAB <br />I THICKNESS <br />REINF. <br />REMARKS <br />6x6 W1.4xW1.4 OVER <br />GENERAL <br />3 1/2' <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH W' LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />TO <br />SH?RT <br />LONG <br />FMA2X12 <br />12' <br />CONTINUOUS <br />12, <br />- <br />O s <br />FMA2x18 <br />12' <br />CONTINUOUS <br />18" <br />- <br />(2)#5's <br />FMAISX18 <br />1S, <br />CONTINUOUS <br />16' <br />- <br />s <br />FMC-12X18 <br />12' <br />CONTINUOUS <br />1S' <br />- <br />s <br />VARIES <br />1441 N. RONALD REAGAN BL <br />LONGWOOD,FL32750 <br />PH: 407-77"078 <br />FAX: 407-7744078 <br />www.abdesigngmup.com <br />l AA #: 0003325 <br />as <br />�1°C$e <br />eUBDM ae LOT: <br />SILVERADO <br />LOT #25 <br />BLK #7 <br />PROJECT# <br />04128.002-25071 <br />MODELS <br />4EBB <br />"1828—CALI" <br />GARAGE 8MMO: <br />RIGHT <br />PAGE: <br />FOUNDATION <br />PLAN <br />150 MPH EXP. B <br />7C <br />L, <br />ATE:,, 08/20/19 <br />SCALE: 1/4"=1'-0" <br />a <br />s1 <br />