My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7134 Silverado Ranch
Zephyrhills
>
Building Department
>
Building Plans
>
7134 Silverado Ranch
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:30:40 PM
Creation date
2/19/2025 11:57:01 AM
Metadata
Fields
Template:
Building Plans
Street #
7134
Location
Silverado Ranch
Contractor
DR Horton
Building Plans - Permit #
21948
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS MALL 15E CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS 814ALL SE SEALED WITH GLASS PAS 4 MASTIC, AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN CLASS i AIR DUCT AS PER NPPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />T: BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO IDE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALL$ SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND MC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER PAN OR EQUAL. <br />PANTECH DBF 110 DRYER 5006TER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE <br />HVAC TO HAVE PROPER <br />PAN$ W/ DRAINS <br />>ALL <br />ATTICCEILING <br />EXTERIOR WALL <br />PLENUM <br />ty <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFOW <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />VMECHANICAL <br />F5CR 6TH EDITION (2011) <br />BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />�—FITTING OR EXTENSION TO <br />BOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/$PEC <br />LEGEND <br />® <br />SUPPLY AIR DIFFLIMR <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY Dff`USER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. <br />W/ (2)-3/I6'X2' TAPCON9 IDAV _IW 81MP80N WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />GSXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN CGNO. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vFL00R SLAB CLEAN -OUT (TYQ I)EXT. GROUND CLEAN -OUT (TYPN <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL DE INSTALLED AT OR <br />A5OVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />SCALE, 1/4 • 1'-0' <br />:ml <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />www.abdosigngmup.com <br />AA N: 0003325 <br />� <br />a <br />C <br />Ias <br />i <br />dww <br />6 <br />A <br />aVBDrv. de LOT: <br />SILVERADO <br />LOT #25 <br />BLK #7 <br />PROJECTp <br />04128.002-25071 <br />MODEL: <br />4EBB <br />"1828—CALI" <br />GARAGE BWINO: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />l� <br />wT : 08/20/19 <br />8C :1/4"=1'-0" <br />>9iiEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.