Laserfiche WebLink
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL` BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICNG, PER <br />MPG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FA15 • MASTIC. AND <br />INSTALLED AS PER PBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (21011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (201'I) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL NAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND RIC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />PANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST PAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />IS <br />PASS-THRU AIR GRILL <br />FREE DRAW AIR <br />HANDLER CLOSET <br />W/LOUVERED DOOR <br />SUPPLIED BY <br />BUILDER <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE, 1/4 . I'-0' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407.774-4078 <br />www.abdosigngroup.com <br />AA S: 0003325 <br />evsaiv k LOT: <br />SILVERADO <br />LOT #6 <br />BLK #17 <br />PROJECT# <br />04128.002-06171 <br />1LODELa <br />3EFB <br />"2447— ROBIE" <br />GARAGE BTIING: <br />RIGHT <br />PAGE: <br />SECOND FLOOR <br />MECHANICAL <br />PLAN <br />50 MPH EXP. <br />DAM- <br />A 10/09/19 <br />BCA=: i/4' = 1'-0* <br />BHEET <br />M2 <br />