My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7158 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7158 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:35:40 PM
Creation date
2/19/2025 11:57:45 AM
Metadata
Fields
Template:
Building Plans
Street #
7158
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22281
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />L BOTTOM, 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z DEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE014' CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />F_Iderlor lathing and plaetedna <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRD LAYER -1, <br />, .... <br />STUCCO WRAP <br />II <br />' � � HOODED VENT <br />t: <br />y : i' THICK, 3 COAT CEMENT <br />{, <br />PLASTER <br />METAL LATH <br />WRS LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 2.5 LBS. <br />PER 60. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 1 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP I SIDES <br />(9 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' — — — —) <br />PIPE T <br />WALL HROUGH <br />1 <br />6' SELF ADHESIVE—, <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />(A),VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEI <br />VERIFY LO <br />NICCii IV RCI.CIVC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />--ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC, <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEURAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FA4 <br />EDGE <br />APPLY E-Z <br />OVER 6m MI <br />GRADE 'D' <br />FELT-F'ROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD <br />CCNSTRICTICH <br />v CM <br />WOOD SHEATHING <br />�—WRm LATER -1, <br />STUCCO WRAP <br />/—WLAYER 4, FORTIFIBER <br />BRB UILDING PAPER <br />,�—FETAL LATH <br />,-T/a' TEMURED <br />FINISH • WOOD <br />FASTEN TO WOOD STItllCfl1RAL <br />�MEMEER • T' O.C. MAX <br />WEEP �D -WALL <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />(�4 HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S. <br />WRB LAYER h, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF-ADHERINGto <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />P <br />STEP #1 <br />STEP 02 <br />77qtl <br />LAYER h, <br />.1 1 STUCCO <br />STUCCO WRAP <br />STEP #3 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />® j�MEMBRANE FLASHING <br />`WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ CV. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />;&METAL LATH <br />STEP 05 STEP #(o <br />@)ELECTRICAL RECEPTACLE <br />r� <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeWpgroup.com <br />AA M: 0003325 <br />Z <br />A <br />s3 <br />Slit <br />M <br />C <br />ty <br />c <br />a <br />�e <br />e <br />sr,>s„> v' a: ��: <br />SILVERADO <br />LOT #8 <br />BLK #17 <br />412 00�-08171 <br />MOD <br />4EAB <br />"1672- ARIA" <br />Gw1RAG! MWO: <br />LEFT <br />PAiGO <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />DATM 12/03/19 <br />SCAM 1/4"=1'-0" <br />slim= <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.