Laserfiche WebLink
41) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9)10d x 1 }" NAILS TO TRUSS <br />42) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d x 1 }" NAILS TO TRUSS <br />DBL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS(NOT SHOWN) <br />41) SIMPSON LGT2 GIRDER TIE. WITH <br />(16) 10d x 3 J' NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12)16d x 3,? NAILS TO GIRDER <br />W, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3)16d <br />GALV. COMMON NAILS. <br />1x2 SECURED W/ 10d <br />GALV. COMMON NAILS <br />12, O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOFANALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: APT SYP #27'x 4", <br />6'. 6' x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3' <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEERED WOOD <br />TRUSSES @ 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT = U:1810 LBS, L770 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U:2365 LBS, L1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) <br />S1 e 1 1 TYPICAL TRUSS/ <br />"' 1L 1� GIRDER CONNECTOR(S) _ <br />BACM BLOCK <br />Tr000 8314" <br />WOOD PANELS <br />k <br />(2)12' WOOD PANELS(2)12" <br />WOOD PANELS <br />2x LUMBER <br />314" T 8 G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG IJOIST <br />5/8" GYPSUM BOARD OR 12' HIGH <br />STRENGTH CLG. BOARD <br />SECURE IJOIST TO TOP PLATE <br />w/ (2)12d TOENAILS <br />DOUBLE TOP PLATE <br />2x4 OR 2x6 WOOD BEARING <br />WALL W/ SYP No 2 STUDS SEE <br />PLANS FOR SPACING. SINGLE <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />12'GYP. WL. BD. <br />r,_'�I-JOIST CONNECTION @ L.B.W. <br />'+ SCALE:3/4"=T-0" (NO UPLIFT) <br />OUTER 1/3 OF <br />SPAN ONLY <br />BTM. - <br />PLATE <br />DEPTH 1/4-D <br />—HOLE EDGE>5ff <br />-HOLE DIAMETER <br />2/5•D SGL. STUD <br />HOLE EDGE >5/6' <br />HOLE DIAMETER <br />< 315•0 DBL. STUD <br />STUD NOTCHING <br />AND BORING LIMITS <br />V SCALE: 1 12'=1'-0' <br />0 24" 0/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETA16 <br />TRUSS ANCHOR WITH <br />(9)10d x 1 k' NAILS TO <br />GIRDER, PROVIDE 6' <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />"ROOFM/ALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP #2 2' x 4", <br />6", W x 4W' MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />L—A41) SIMPSON LGT3SDS2.5 GIRDER TIEDOWN <br />WITH (4) j' x 6' TITEN HD TO CMU AND (12) SOS <br />tt'x2j"TO GIRDER <br />B-(t) SIMPSON FGTR GIRDER TIEDOWN WITH <br />(2) J" x 5" TITEN HD TO CMU AND (18) SOS }" x <br />lx2, 2a WOOD FASCIA. <br />3" TO GIRDER <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3) 16d <br />C42) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />GALV. COMMON NAILS. <br />(2) J" x 67[TEN HD TO CMU AND (18) SDS }" x 3' <br />lx2 SECURED W/ lOd MASONRY BOND <br />SCREWS TO GIRDER (EACH TIEDOWN) <br />GALV. COMMON NAILS BEAM <br />ENSURE THAT CELLS ARE GROUTED <br />17' O/C SEE SCHEDULE <br />SOLID, 6' EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT =4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = BBS5 LBS (2 PLY MIN.) <br />2A 26 2C TYPICAL ROOF <br />GIRDER CONNECTOR(S) <br />LSTA12 20 GAUGE <br />W/ 10dxl2 HOG COMMON NAILS. <br />0 EACH END TOTAL OF 10 <br />8 <br />WICKERa CK <br />TWpO®8 <br />46M <br />3/4" WOOD PANELS <br />s000 <br />(2) 12" WOOD PANELS <br />80 <br />(2) W- WOOD PANELS <br />90 <br />2x LUMBER <br />LVUWOIST WITH <br />BACKER BLOCK <br />W/ 5/8" A.B. WITH <br />MIN. <br />MIN. T' EMBEDMENT <br />TO SLAB 8 (18) t6d x <br />2.12' NAILS TO POST., <br />POST TO SIT DIRECTLY <br />ON SLAB <br />4. <br />.4. 4. <br />LVL/WOOD POST CONNECTIONS <br />5 SCALE: 3/4"=V-9' <br />A - SIMPSON HUS28 G < 12DO LBS, U < 1280 LBS W/ (1) 3/4" SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (8)16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4" SIMPSON TITEN BOLT/J-BOLT, 6' MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (10) 16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28.2 G < 2400 LBS, U < 1810 LBS W/ (2) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 6' <br />MIN. EMBED (36)16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS2&2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"° SIMPSON TITEN BOLT/J-BOLT, S' <br />MIN. EMBED (36)18d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W/ (4) 34" SIMPSON TITEN BOLT/J-BOLT, 6' <br />MIN. EMBED (36)16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: <br />It 1100 UPLIFT SIMPSON — <br />HTSM2D W/1010d TO <br />TRUSS AND (4) ll4" x 2114' <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/1010d TO <br />TRUSS AND (4)114" x 21/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN. <br />7' COVER 8 7' APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />6-0' MAX (W/1X4) <br />OR 10.0" MAX (W/2X4) <br />lx4 DIAGONAL <br />BTM.CHORD <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />10 BTM. CHORD BRACING 6-0" OIC END WALL OR OTHER <br />MAX., OR 20 BTM. CHORD BRACING END TYPE CONDITION, IF <br />10-0" O/C MAXSECURED W/ (2)1Od DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD �+ /� /+ <br />INTERSECTION TYP. 6 CHORD HORD BRACING <br />V EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE STM <br />CHEDUL <br />SCHEDULE SEE FRAMING PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />SEE LEDGER SCHEDULE W <br />512' MIN, EMBED.(TYP) <br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, WALL AROUND <br />BOLT. <br />°d Z <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />LAP A MIN OF 44'. <br />3. ALL BOLTS TO HAVE WASHERS <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />CLOSER THAN 6' O/C. <br />S. IN LIEU OF HILT[ PAPS SIMPSON TITEN 1W <br />(2) _ PT <br />DIA. x 3' MASONRY SCREWS MAY BE USED, <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLTSIZE <br />WEDGEBPA= <br />CENIRLLBPACBNi <br />A <br />DOUBLE 2x8 <br />12' <br />S. O/C <br />16, O/C <br />B <br />DOUBLE 218 <br />3/4" <br />W O/C <br />24" O/C <br />C <br />DOUBLE 200 <br />12' <br />8" O/C <br />16, O/C <br />D <br />DOUBLE 2.10 <br />3/4" <br />W. O/C <br />24" O/C <br />E <br />DOUBLE Z00 <br />3/4" <br />6' O/C <br />1S, O/C <br />F <br />DOUBLE 2x12 <br />3/4" <br />S" O/C <br />12, O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 31,V-V-U' <br />(2) 2X4 No.2 SYP DIAG. — <br />BRACE W/ (3) 12d 0 EA <br />TRUSS (DIAG. BRACE TO <br />COVER 5 TRUSSES) <br />0'-0" TO 30'4' (1)'X' BRACE <br />30'-l" TO W-0 (3)'W' BRACE <br />(1) "X' BRACE G CENTER <br />(2) "X" BRACE DIVIDED EQUALLY <br />FROM CENTER TO END. <br />2x WOOD FASCIA, - <br />SEE ARCHITECTURAL <br />PRE-ENG GABLE TRUSS —� <br />STIFFBACK (AS PER <br />TRUSSENG) <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />2(4 BLOCKING BETWEEN <br />TRUSSES WHERE <br />X-BRACING IS PRESENT AT <br />4'-U'O.C. (AT SHEATHING <br />SEAMS) <br />SECURE 2x8 PT. PLATE <br />TO BLK W/ 12' DIA <br />ANCHOR BOLT W/ 7' <br />WASHER SET IN HIGH <br />STRENGTH EPDXY 6' <br />MIN. EMBED. AT 37' OC <br />MAX. <br />SECURE GABLE TO 2.8 <br />P.T. PLATE W/ 12d's 8" <br />O.C. MAX <br />CONT. 2x4 SECURED W/ <br />(2) 10d's Q EACH TRUSS <br />TO BE INSTALLED 0 <br />1(Y-0" O.C. MAX. <br />7 BLOCK WALL W/ GABLE END <br />PRE-ENG'D TRUSS SCALE:3/4"=V-a' <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED 60 LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Fl AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 <br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO Fl AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE: 3/4'=V-0" <br />A706010. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH:407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M: 0003326 <br />�m <br />stmDIv ac I407; <br />SILVERADO <br />LOT #11 <br />BLK. #14 <br />PROJECT# <br />03719.000-11141 <br />HODEIe <br />°2558-HAWTHORNS" <br />GA1tA0E 8VW0. <br />RIGHT <br />PAGE; <br />DETAILJ.B <br />150 H E <br />