My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7172 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7172 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:54:16 PM
Creation date
2/19/2025 12:00:18 PM
Metadata
Fields
Template:
Building Plans
Street #
7172
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22580
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL b' SELF-ADHERMG <br />MEMBRANE FLASHING OVER <br />TOP, SOWS) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />OF OF FLASHING TO DE, <br />L EOtTOM. 2. SIDES. & TOP <br />VENT CAP IS TO BE SET M BED <br />OF SEALANT AT TOP AND <br />BIDES ONLY. SEALANT 18 TO BE <br />TOOLED 80 A8 TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROWD <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON 81DE&V CAULKING • JOINT <br />ALL <br />PER SECTION R703.7 <br />E4wlor b tkw W4 0l XWM <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER M, <br />X; <br />STUCCO UAQAf° <br />I .:; <br />HOODED VENT <br />X, j' THICK, 8 COAT CEMENT <br />PLASTER <br />METAL LATH <br />UM LAYER Q, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />© DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER ...... <br />— — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEI <br />VERIFY LO <br />STUCCO <br />FINISH <br />h' SELF ADHESIVE <br />OVER TOP t SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />LAYER 9, <br />UNIT <br />STUCCO WRAP <br />LAYER O, FORTRISER <br />PREMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />TP(Tu w <br />COWTPZ=lCN y�FINI•SH * WOOD <br />FASTEN TO WOOD STRICTURAL <br />SEALANT • <br />t MEMBER • 9' = MAX <br />TOP t SIDES <br />• cru <br />., �.76• ToM42-UIALL <br />9 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'CLICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />V SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MAM F. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH" <br />A VENT PENETRATION <br />SCALE: N.T.B. <br />STUCCO SCRATCH COAT <br />t 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING: <br />APPROVED <br />HOUSEWRAP <br />ELEC. METER FIELD <br />BELOW <br />VERIFY LOCATION <br />CUT SUCH T14AMEMBRANE <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY STUCCO SCRATCH COAT <br />APPLY TO FM <br />EDGE <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />--APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />APPLY E-Z BEAC <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />i' WIDE STRIP SELF <br />ADHESIVE FLASHM4 CLEAN <br />MASONRY BEFORE APPLYING <br />(�oHORIZONTAL WEEP SCREED <br />FRAME TO BLOCKZ <br />e' <br />WRB LAYER M, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASFIMG <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />h <br />STEP #1 <br />STEP 02 <br />LAYER 01, <br />STUCCO <br />STUCCO WRAP <br />APPLY 60 MM - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEILRAP <br />STEP #3 <br />® [OMBRANIE FILASHING I <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP 1% <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-77"078 <br />wwwAbdesigngroup.com <br />AA M: 0003325 <br />t <br />: I <br />a <br />$ <br />tj: <br />:1 <br />I <br />: <br />oil <br />: <br />EST <br />[EIVISIDIV. ae LO <br />SILVERADO <br />LOT #9 <br />BLK #17 <br />PROJECT# <br />04128.002-09171 <br />MOasrj <br />4EBB <br />"1828-CALI" <br />GARA0Z S1111►MG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />V.150 MPH EXP. B <br />—"awT"a' `: 12/ 03 19 <br />SCAL C- 1/4"=1'-0" <br />aRMT <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.