My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7187 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7187 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:17:55 PM
Creation date
2/19/2025 11:23:09 AM
Metadata
Fields
Template:
Building Plans
Street #
7187
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
3937
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRAMING NOTES <br />1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE <br />CONCRETE TO WOOD ROOF: SIMPSON HETA18 W/(9)10d x 1 1,7 HDG NALS. <br />CONCRETE TO WOOD FLOOR: <br />SIMPSON LTA2 W/ (8) 10d x 1 1/2"HDG NAILS, WOOD TO WOOD: <br />SIMPSON H10A OR LGT2 W/ 10d x 1 117 HDG NAILS, FILLALL HOLES. <br />2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER <br />SCHEDULE. <br />3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE <br />MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS <br />ARE TO BE GALVANIZED. <br />5, LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, <br />CONNECTERS ARE TO BE GALVANIZED. <br />8, LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE <br />CONCRETE LINTELS. <br />7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND <br />CLEAR SPAN OPENINGS. <br />8. LINTELS SHALL HAVE 4" NOMINAL BEARING (41. <br />9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE <br />SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE <br />FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS <br />LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND <br />APPROVAL. <br />10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES <br />SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED <br />FASTENER, ZF 72 P8S36, .177"' x 2 7/8" LONG, WITH WASHER C 16" O.C. <br />11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END <br />UNLESS OTHERWISE SHOWN DIFFERENT. <br />12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON <br />RATIONAL ANALYSIS. <br />13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS <br />NOTED OTHERWISE. <br />HEADER SCHEDULE <br />MARK <br />p� w� <br />REMARK <br />0 <br />1 (2) 2X12 <br />GENERAL NOTES <br />1) CODES <br />1.1 FLORIDA BUILDING CODE 7UI EDITION, 2020 RESIDENTIAL SECTIONS R4022 g R605. <br />1.2 FLORIDA BUILDING CODE, 71h EDITION, 2020 BUILDING, SECTIONS 19012 g 2107. <br />1.3 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-14). <br />1.4 BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES <br />(TMS 402/602.16) <br />1.5 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND <br />OTHER STRUCTURES (ASCE 7-16). <br />2.)CONCRETE: <br />2.1 CONCRETE COMPRESSIVE STRENGTH AT28 DAYS: <br />2.1.1 PRE -CAST W/STANDARD REINFORCEMENT4000 PSI MIN. <br />2.1.2 PRE -CAST WIPRESTRESS REINFORCEMENT-6000 PSI <br />2.1.3 GROUT PER ASTM C476 - 3000 PSI W/ MAX. 3/8" AGGREGATE, 8" TO 11" SLUMP. <br />2.2 REINFORCING BARS: <br />2.2.1 STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION <br />ASTM A615/A615M (GRADE 60) <br />2.22 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED INFIELD) <br />ASTM A615/A615M (GRADE 40). <br />2.3 PRESTRESS STRANDS ASTM A416 7-WIRE, STRESS RELIEVED 270 KSI <br />2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH AC131&14. <br />2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. <br />2.6 D4.5 WRE PER ASTM AIOWA1084M <br />3) MASONRY: <br />3.1 CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C-90, NORMAL WEIGHT WITH <br />MINIMUM NET AREA COMPRESSIVE STRENGTH 2O00PSI. <br />3.2 MORTAR SHALL CONFORM TO ASTM C270 TYPE "M" OR "S" <br />3.3 FULL MORTAR JOINTS ARE REQUIRED <br />3.4 MINIMUM AGGREGATE 2&DAY COMPRESSIVE STRENGTH OF CMU AND MORTAR SHALL NOT <br />BE LESS THAN FM - 2000 PSI. MASONRY STRENGTH SHALL BE ESTABLISHED BY THE "UNIT <br />STRENGTH METHOD" OR, ALTERNATIVELY, BY THE "PRISM TEST METHOD" MERE USM <br />REQUIREMENTS HAVE NOT BEEN MET. <br />4)STRUCTURAL: <br />4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM <br />ACCEPTABLE BEARING OF 4" PER FLORIDA BUILDING CODE 7TH EDITION, 2020 RESIDENTIAL, <br />SECTION R606.6.3 OR FLORIDA BUILDING CODE 7TH EDITION, 2020 BUILDING, SECTION 2104.1 <br />4.2 SAFE LOAD VALUES BASED ON RATIONAL DESIGN ANALYSIS PER ACI 318-14AND TMS 402-18 <br />4.3 DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY <br />CALCULATING MAXIMUM RESISTING MOMENT AND SHEAR AT d DISTANCE AWAY FROM THE <br />FACE OF THE SUPPORT. <br />4.4 FOR LINTEL LENGTH AT 6'-0" OR GREATER, VERTICAL CELL FILLED SOLID WITH GROUTAND <br />MINIMUM ONE (1) #5 VERTICAL REBAR IS REQUIRED AT EACH END OF THE LINTEL. <br />4.5 LINTELS THAT ARE GREATER THAN 14'-0" CLEAR SPAN MUST BE PROVIDED TEMPORARY <br />SUPPORT, NOT BE REMOVED UNTIL 2 DAYS AFTER GROUT PLACEMENT. <br />LIFT BEAM P <br />fWDesolgn <br />441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32780 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdsslgagroup.mm <br />AA #: 0003325 <br />pr DRAFTING BY.- <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-886-2628 <br />FAX: 8134186.2902 <br />
The URL can be used to link to this page
Your browser does not support the video tag.