Laserfiche WebLink
A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(B)90tl x 1 z' NAILS TO TRUSS <br />B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d x 1 � NAILS TO TRUSS <br />DBL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C-(i) SIMPSON LGT2 GIRDER TIEDOWN WTH <br />(16) 1Od x 3 }" NAILS TO GIRDER AND <br />(2)SIMPSON HETAI6 TRUSS ANCHORS <br />WITH (12)16d x 3 J' NAILS TO GIRDER <br />lx2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/(3)16d <br />GALV. COMMON NAILS. <br />lx2 SECURED W/ 10d <br />GALV. COMMON NAILS <br />12' O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALL/FLOOR <br />SHEATHING <br />FASTENER SCHEDULE' <br />NOTE: APT SYP #27 x 4", <br />8", 8" x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEERED WOOD <br />TRUSSES 0 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT c U: 1810 LBS, L770 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) <br />1A 1B 1C TYPICAL TRUSS/ <br />GIRDER CONNECTOR(S) SCALE: al4"=l'-0" <br />>99$ <br />BAC103l BLOCK <br />THO" <br />4500 <br />3X' WOOD PANELS <br />6000 <br />(2) 1/2"WOOD PANELS <br />60 <br />(2) in" WOOD PANELS <br />90 <br />2x LUMBER <br />3/4" T & G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG IJOIST <br />518" GYPSUM BOARD OR 1/7' HIGH <br />STRENGTH CLG BOARD <br />SECURE I -JOIST TO TOP PLATE <br />W (2) 12d TOENAILS <br />DOUBLE TOP PLATE <br />2x4 OR 2x8 WOOD BEARING <br />WALL W/ SYP No 2 STUDS SEE <br />PLANS FOR SPACING. SINGLE <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL TOP PLATE <br />PROVIDE BLOCKING <br />in" GYP. WL BD. <br />SEE SHEET SlAA FOR <br />NAIL SIZE AND PATTERN <br />G <br />I -JOIST CONNECTION L.B.W. <br />SCALE 34-' 0 (NO UPLIFT) <br />DEPTH 1/4-D <br />—HOLE EDGE>5/8" <br />—HOLE DIAMETER <br />< 2/5'0 SOL. STUD <br />OUTER 1/3 OF <br />SPAN ONLY <br />BTM. - <br />PLATE <br />STUD NOTCHING <br />AND BORING LIMITS <br />8 SCALE: 1 17=1'-0 <br />EDGE>561 <br />HOLE DIAMETER <br />< 3/5`0 DBL. STUD <br />ENGINEERED WOOD TR( <br />0 24" O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETAI6 — <br />TRUSS ANCHOR WITH <br />(9) 10d x 1 }' NAILS TO <br />GIRDER. PROVIDES' <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALLIFLOOR <br />SHEATHING <br />FASTENER SCHEDULE' <br />NOTE: APT SYP #27'. 4", <br />6", 8" x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3' <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />—A-(1) SIMPSON LGT3-SDS2.5 GIRDERTIEDOWN <br />WITH (4) t' x 5" TITEN HD TO CMU AND (12) SDS <br />}' x 2 �' TO GIRDER <br />B-(1) SIMPSON FGTR GIRDER TIEDCWN WITH <br />(2) }' x 5" TITEN HD TO CMU AND (18) SDS *'x <br />1 x2, 2x WOOD FASCIA <br />3" TO GIRDER <br />SEE ARCHITECTURAL <br />C-(2) SIMPSON FGTR GIRDER TIEDOWIJS WITH <br />2x SECURED W/(3)16d <br />(2) i' x 5"TITEN HD TO CMU AND (18) SDS +' x 3" <br />GALV. COMMON NAILS. <br />lx2 SECURED W/ 1Dd <br />MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN) <br />GALV, COMMON NAILS <br />BEAM ENSURE THAT CELLS ARE GROUTED <br />17' O/C <br />SEE SCHEDULE SOLID, 8" EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (20R 3 PLY) <br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) <br />2A 26 2C TYPICAL ROOF <br />GIRDER CONNECTOR(S) SCALE:" <br />BF <br />BACI03t BLOCK <br />7MC10®1 <br />1500 <br />3/4" WOOD PANELS <br />8000 <br />(2) 1n" WOOD PANELS <br />80 <br />(2) in" WOOD PANELS <br />BO <br />2z LUMBER <br />LSTA12 20 GAUGE <br />W/ tOdxi 2 HOG COMMON NAILS. <br />EACH END TOTAL OF 10 <br />LVUI-JOISTWITH <br />BACKER BLOCK <br />HT14 W/&S'A.B. WITH <br />MIN. 7"EMBEDMENT <br />TO SLAB & (18)16d x <br />2-1/2" NAILS TO POST. <br />POST TO SIT DIRECTLY <br />ON SLAB <br />4:. 4 �. <br />LVLMOOD POST CONNECTIONS <br />5 SCALE: 3/4"=V-a' <br />NOTE <br />A - WHEN TRUSS BEAR ON TOP OF LEDGER USE SIMPSON HTS20 FROM <br />A - SIMPSON HUS28 G < 1200 LBS, U < 1260 LBS W/ (1) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (8)16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (10)16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G < 2400 LBS, U < 1810 LBS W/(2) 3/4"" SIMPSON TITEN BOLT6IBOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4'" SIMPSON TITEN BOLT/J-BOLT, 5' <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12)18d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W (4) 3/4'" SIMPSON TITEN BOLT/J-BOLT, 5' <br />MIN. EMBED (38) 16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: <br /># 1100 UPLIFT SIMPSON - <br />HTSM20 W/1010d TO <br />TRUSS AND (4) 1/4" x 2 114" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/1010d TO <br />TRUSS AND (4) 1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POUREOUNTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN, <br />2" COVER & 7APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />3 SCALE: 3/4"=1'-a' <br />6'-0" MAX (W/lX4) <br />QR 10'-0" MAX (W/2X4) <br />lx4 BTM. CHORD BRACING 6'A"O/C <br />MAX, OR 2.4 BTM. CHORD BRACING <br />10'-0" O/C MAXSECURED W/ (2)10d <br />COMMON NAILS AT EACH CHORD <br />INTERSECTION TYP. BTM. CHORD BRACING <br />6 SCALE: 3/4"=l' (P <br />ix4 DIAGONAL <br />BTM.CHORD <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />END WALL OR OTHER <br />END TYPE CONDITION, IF <br />DEPICTED SEE PLAN <br />5'EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE <br />HEDUL <br />SCHEDULE SEE FRAMINGPLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />onc <br />SEE LEDGER SCHEDULE W <br />5 in" MIN. EMBED. (TYP) <br />i. ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, WALL AROUND <br />BOLT, <br />Z <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />a0 g <br />LAP A MIN OF 4'-0". <br />3. ALL BOLTS TO HAVE WASHERS <br />= <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />°p <br />CLOSER THAN 8" O/C. <br />5. IN LIEU OF HILT[ PAPS SIMPSON TITEN 1/4" <br />(2) _ PT <br />DIA. x 3" MASONRY SCREWS MAY BE USED, <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />VEDGEBPACIIG <br />CDRRALBPAM <br />A <br />DOUBLE 2x8 <br />1/7, <br />8" WC <br />16, O/C <br />B <br />DOUBLE 2x8 <br />3/4" <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 2x10 <br />1/7, <br />81,010 <br />16, O/C <br />D <br />DOUBLE 2110 <br />3/4" <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 2110 <br />314" <br />fill O/C <br />16' O/C <br />F <br />DOUBLE 2112 <br />3/4" <br />6" O/C <br />12' O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 3/4"=1'-a' <br />(2) 2X4 No.2 SYP OIAG. <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3) 12d 4D EA <br />TRUSSES MERE <br />TRUSS(DIAG. BRACE TO <br />X-BRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4'-0" O,C. (AT SHEATHING <br />0'-0" TO 30'-0" (1) W BRACE <br />SEAMS) <br />30'-1" TO 80'-0 (3) "X" BRACE <br />SECURE 2x8 PT. PLATE <br />(1) "X" BRACE O CENTER <br />TO BLK WI 1/2" DIA <br />(2) "X" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/7' <br />FROM CENTER TO END. <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 6' <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 37'OC <br />MAX. <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />P.T. PLATE W/12d's 8" <br />STIFFBACK (AS PER <br />O.C. MAX <br />TRUSS ENG) <br />CONT. 2x4 SECURED <br />(2) 10d% 4B EACH TRUSS <br />TO BE INSTALLED <br />10'-O" O.C. MAX <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />BLOCK WALL W/ GABLE END _ <br />PRE-ENG'D TRUSS SDALE:�""=10' <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Fi AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON HiOA OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, Fl, AND F2 <br />FORCES ALL AT THE SAME TIME, FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO F1 AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE: <br />ro�u� <br />7 <br />441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774.4078 <br />www.abdosig0group.00m <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134386-2628 <br />FAX: 813.886.2802 <br />