My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7197 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7197 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:30:20 PM
Creation date
2/19/2025 12:22:39 PM
Metadata
Fields
Template:
Building Plans
Street #
7191
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
557
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT 014ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $HALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. PREBH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOUTERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIR: RATED CEILINGS AND WALLS SHALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND POO 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER PAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE. RETURN TRUNK <br />l <br />BALANCNG DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN t LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />SECURE STRAP TO CONC. R <br />P <br />PLENUM <br />T y <br />AIR RETURN Ulf/ (2)-3A6'X2' TAPCONB UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE STRAP TO UNIT W/ (2) <br />AIR HANDLER---y <br />EXTERIOR WALL <br />4' CONCRETE SLAD sBXI 1/4' BHT. MTL. SCREWS <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAD <br />CONNECTION TO PAD <br />p <br />REFRIGERANT LINES TO <br />PLATFOR'1 <br />RETURN <br />UNIT <br />NOTE: MAIN GOND. DRAIN 3/4' DIA. <br />IVCCNPENSIWG <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD • 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3013A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />FIN. FLOOR <br />COUNTERSUNK <br />BRONZE FL. PL. <br />OR WALL <br />C.O. PLUG <br />SEE SPEC. <br />m <br />BRASS PLUG <br />I'-8'X8' GONG. <br />FIN. GRADE <br />FITTING OR EXTENSION TO <br />OR PAVING <br />SOIL OR WASTE AS <br />REQUIRED <br />FITTING OR <br />EXTENSION TO SOIL <br />WADE 8240-K JOSAM 56MO <br />OR WASTE AS <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />REQUIRED <br />CAULK <br />P.V.0 OPTI/SPEC <br />FLOOR_ SLAB CLEAN -OUT (TYP.) .3EXT. GROUND CLEAN -OUT (TYPN� <br />MECHANICAL PLAN <br />SCALE= 1/4' . P-0' <br />114 <br />A R C N I T e C T 3 <br />Groupl. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6076 <br />FAX: 407-7744078 <br />www.abdoslgngrouP.com <br />AA B: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5436 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33834 <br />PH: 8134862628 <br />FAX: 61S88&2802 <br />