7199 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7199 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:37:00 PM
Creation date
2/19/2025 12:20:49 PM
Metadata
Fields
Template:
Building Plans
Street #
7199
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
559
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u e u i* u e• <br />HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS, <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER F15C 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 151 CLASS I AIR DUCT AS PER NFPA WA 2-3) <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRZTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(20TU MECHANICAL CODE 6031 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITNFBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SMALL NAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RE0"IENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10, GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFR)SER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR 080 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-TI-M AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING O O <br />EXTERIOR WALL <br />SECURE STRAP TO GONG <br />PLENUM <br />AIR RETURN <br />W/ (2)-3/16'X2' TAPCON$ UNIITR T <br />SIMPSCN WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY 1 <br />REFRIGERANT LINER <br />1 <br />SECURE STRAP TO UNIT W/ (2) <br />AIR HANDLER <br />EXTERIOR WALL <br />4' CONCRETE SLAB <br />4aXl I/4' BHT. I'1TL. SCREWS <br />b <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER <br />UNIT <br />EVAR TRAY d <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION <br />TO PAD <br />T <br />REFRIGERANT LINES TO <br />PLATFORM RETURN <br />CONDENSING UNIT <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION U".2.4 <br />HVAC <br />DRAINS <br />SC0MATED NICKEL <br />FIN. FLOOR <br />SNK <br />GOU IO. PLUUG <br />BRONZE FL. PL. <br />OR WALL <br />—� <br />SEE SPEC. <br />r-e•Xa• coNc. <br />BRASS PLUG <br />FIN. GRADE <br />OR PAVING <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION) TO SOIL <br />OR WASTE AS <br />.,—WADE 9240-K JOSAM 56000 <br />REQUIRED <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />CAULK <br />P.VC OPTVSPEC <br />FLOOR SLAB CLEAN -OUT (TYPN nEXT. GROUND CLEAN -OUT (TYPNT5 <br />a <br />MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0' <br />6 <br />Groin <br />1441 N. RONALD REAGAN BLVO. <br />LONGWOOD, FL 32750 <br />PH: 407-774,6078 <br />FAK 407-774-4078 <br />www.abdosigngroup.com <br />L AA N: 0003325 <br />F <br />h <br />v <br />M <br />0 <br />D <br />Rs <br />G <br />SUBDIV & LOT: <br />SILVERADO <br />LOT #1 <br />BLR. #18 <br />PROJECTW <br />03719.000-01182 <br />MODEL: <br />"2045-LWANA" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. Bff <br />RIO <br />1.1411prT 8/03/20 <br />DATE: <br />SCALE: 1/4"=1'-0" <br />M1 <br />