Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, BIDE(S) AND DOTTOM <br />FLANGES OF NON-MOVAEILE <br />FRAME OF THE EXHAUST. <br />BE�e OF FLASHING TO BE, <br />I' x: <br />I. BOTTOM. 2. BIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />- <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z EIEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER Or - <br />BACKER ROD <br />t <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES. Yi CAULKING • JOINT <br />I <br />I <br />ALL AROUND <br />PER SECTION R 03.7 <br />Exterior laftna and Dlasterina <br />BACKER ROD <br />I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />x- <br />1 <br />1 <br />X <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />V <br />or ASTM 1787. <br />WRB LAYER -I, <br />X <br />STUCCO WRAP <br />rf <br />- <br />HOODED VENT <br />3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRS LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING. <br />DRYER VENT <br />(FRAME) <br />SHEATHING <br />LAYER h, <br />= WRAP <br />LAYER -2, FORTIFIBER <br />WOOD - <br />CONSTUCTION <br />-METAL LATH <br />S' cm VINYL CASING BEAD <br />W RAISED BAND <br />asi )V MIDI -WALL <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYIN <br />Z PLAS14NG <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINACsE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — -- — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-641-14a, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEi <br />VERIFY LC <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT* <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />6' SELF ADHESIVE_ <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPEi <br />UNDER 'QUICK FLASI <br />WOOD CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDINKs PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />36' TO V MID -WALL <br />WEEP SCREED <br />CONBTRUCTICN i' <br />6' SELF-ADHESIVE <br />FLASHING a cMu <br />WOOD FRAMED <br />F_ - - - —I WALL <br />_ HORIZONTAL WEEP SCREED ' <br />( FRAME TO FRAMES <br />A VENT PENETRATION <br />h SCALE: N.T.S. <br />fiIGCN Iv ICClrC1YC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHir <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHMK. <br />UM LAYER 9, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER - T' OG. MAX <br />.... aLaw ALL <br />.6' WIDE STRIP SELF <br />ADHESIVE PLAS14W., CLEAN <br />MASONRY BEFORE APPLYING <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP #1 <br />5TEfi #3 <br />a• <br />WRB LAYER -I, <br />STUCCO WRAP <br />WRB LAYER 51, <br />STUCCO WRAP <br />9 APPLYY 6(D MIN <br />SELF -ADHERING <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) MAR <br />METAL LATH <br />STEP 05 STEP #(o <br />OELECTRICAL RECEPTACLE <br />A R e N I T e e T: <br />6 <br />GroulLLP <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774.4078 <br />www.abdosigngroup.com <br />AA k: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134386.2628 <br />FAX: 613.88&2802 <br />�annnmo <br />