Fa <br />MECHANICAL PLAN <br />SCALE, 1/4' • 1'-®' <br />HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT 814ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAD 4 MASTIC. AND <br />INSTALLED AS PER RIC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 PT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER PBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SMALL BE CONSTRUCTED IN ACCORDANCE TO POO 1T14 EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH MC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S, ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOOR& TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II, DRYER BOOSTER TO BE A PANTECH PEP 5006TER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />NOSE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />EXTERIOR WALL <br />AIR RETURN <br />SUCTION AND LIMID <br />AIR SUPPLY_ --II I I I I REFRIGERANT LINES <br />AIR <br />EVAP. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TMR K <br />l <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE <br />STRAP <br />TOPCONDENSER <br />UV UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />TO UNIT U.V <br />RETURNlfi CONDENSING UNIT <br />0VE8 TO 4' CCNCRETE SLAB �(II 1//4' SHTR.AMTL. SCREWS (2) <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 301.2A <br />HVAC DRAINS <br />1' <br />EXTERIOR WALL <br />314' PVC CONDENSATE DRAIN LINE <br />j PVC SLEEVE TO LINES BELOW SLAB <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRICTURE <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL C.O. PLUG <br />BRASS PLUG <br />SEE SPEC, <br />I'-B'X8' CONC, <br />FIN. GRADE -� <br />�--FITTING OR EXTENSION TO OR PAVING <br />&OIL OR WASTE AS <br />REQUIRED FITTING OR <br />EXTENSION TO SOIL <br />WADE 6240-K JOSAM BOOM OR WASTE AS <br />INSIDE SERIES NICKEL BRASS TOP REQUIRED <br />CAULK P.V.0 OPTI/SPEC <br />INV. SEE <br />ITE PLAN INV. SEE <br />AA <br />vFL00R SLAB CLEAN -OUT (T� NEXT. GROUND CLEAN -OUT (TYPN ) <br />�IlaN I T 1 <br />6 <br />Grow;Ln. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774,6078 <br />FAX: 407-774.4078 <br />www.abdosigngroup.com <br />AA 8: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33834 <br />PH: 813886-2628 <br />64 FAX: 81S4886-2802 <br />DRINT <br />w 02/05/21 <br />EH3mm <br />M1 <br />