My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7297 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7297 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:28:35 PM
Creation date
2/19/2025 11:14:38 AM
Metadata
Fields
Template:
Building Plans
Street #
7297
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1534
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL V SELF -ADHERING <br />MEMBRANE PLAS149JG OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECAJENCE OF PLASHINS TO BE: <br />L BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT I$ TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />1 <br />..'L: <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />' <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE& AW CAULI NCs - JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R703.7 <br />1 <br />Exterior lathing and D <br />I <br />Exterior use of portland cement plaster <br />BACKER ROD <br />shall comply with the application <br />- <br />requirements of ASTM C 926-18b. <br />kInstallation <br />of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRB LAYER 9, <br />871.ICC0 WRAP <br />HOODED VENT <br />J' THICK 3 COAT CEMENT <br />I, <br />.X: <br />PLASTER <br />METAL LATH <br />WAS LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SWEAT14NG <br />DRYER VENT <br />( FRAME) <br />r <br />SHEATHNG <br />AYER WRAPAYER 4, FORTIFIBER <br />NG PAPER <br />oHeTucrloN <br />6' WIDE STRIP SELF <br />ADHESIVE K A6WIN3, CLEMt <br />MASONRY BEFORE APPLYING <br />Z PLAS1Ie1G <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER al, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — • — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-641-14a, MIN. 25 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANLIF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUCsH / <br />WALLI <br />&' SELF ADHESIVE — <br />FLASHNG INSTALL <br />PER MANUF. SPECS-) <br />BUILDING PAPEI <br />UNDER 'QUICK FLABF <br />A VENT PENETRATION <br />SCALE: N.Tb. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />4' `ELEC. METER FIELD <br />y VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />THICK 3 COAT CEMENT <br />Ys' TO Yo' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />1-�/ I -T. WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />r0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWIPAP <br />FOR BOX INSTALLATION <br />WRB LAYER 9, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEURAP <br />BELOW <br />r1a.Ar e <br />PLANE <br />BOX, <br />FACE <br />EDGE <br />CUT SUCH <br />NO MEMB <br />ENTERS <br />APPLY TO <br />S' CMU <br />WOOD SHEATHING <br />JLRS LAYER 1, <br />STUCCO WRAP <br />WRS LAYER 12, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />_1W TEXTURED <br />PHSH - WOOD <br />-FASTEN TO WOOD STFIUC/IRAL <br />MEMBER - T' OL. MAX <br />IV TO Jr Pw4LLALL <br />uEEr era l <br />4.' WDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MA80NR1' BEFORE APPLYING <br />V - PINION -MASON2'Y <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />APPLY E-Z BEAD <br />OVER b® MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP #3 <br />S' <br />WRB LAYER 9, <br />STUCCO WRAP <br />UIRB LAYER 9, <br />STUCCO WRAP <br />APPLY 60 MN <br />SELF -ADHERING <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />NOUSEILRAP <br />WRB LAYER 02, FORTfFIBER <br />BUILDING PAPER <br />STEP <br />*4 <br />ELASTOMERIC <br />COATNCs OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />40-a—METAL LATH <br />STEP 05 STEP "re <br />nELECTRICAL RECEPTACLE <br />1441 N. RONALD REARIIN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-774-4078 <br />wwwabdesigngroup.com <br />AA ik 000332, <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BE UIMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-896.2628 <br />FAX: 813-888-2802 <br />SUDDrV. & LOT <br />SILVERADO <br />LOT #16 <br />BLK #14 <br />PROJECT# <br />03719,000-16 4 <br />mopEu <br />2795-B <br />GARAGE Sl/IBTG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%150 MPH EXP. <br />