My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7297 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7297 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:28:35 PM
Creation date
2/19/2025 11:14:38 AM
Metadata
Fields
Template:
Building Plans
Street #
7297
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1534
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br />HVAC NOTES <br />MECHANICAL PLAN <br />SCALE: 1/4 • V-0' <br />I. ALL MECHANICAL EQUIPMENT BALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL. BE CONSTIOICTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB t MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-33 <br />4. FRESH AIR INTAKES MIALLd91 BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC ITN EDITION <br />(2020) MECHANICAL CODE 603J <br />I. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR 15AT14NO FIXTURES 844ALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC ITN EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, 844ALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED- <br />% ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MPG. REGGFFENDATIONS AND FBC 1T14 <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF IIO DRYER BONER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBO <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />I9 <br />PA86-TWW AIR GRILL <br />HOT: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAMS <br />ATTIC <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />AIR RETURN SECURE STRAP A <br />( <br />TB <br />IT <br />SIMPSON WB ROLL STRAP <br />SUCTION AND LIQUID <br />OR EQUAL <br />AIR SUPPLY <br />1 <br />REFRIGERANT LINES <br />1 <br />AIR HANDLER <br />EXTERIOR WALL <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT Ulf (2) <br />'BXI 1/4' SHT. MTL. BGIQEWb <br />L <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER <br />UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REPRKeERANTLINES TO <br />CONNECTION <br />TO PAD <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />NOTE: MAIN COND. DRAM <br />TRAP DRAM LINE AND TERMINATE <br />OVER HEAD 12FROM STRUCTURE <br />IN AN APROVED DRAM, AS PER <br />F5CR 7T11 EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />RSUNK <br />GOUDA <br />SCORIATED NICKEL <br />FIN. FLOOR <br />. PLUG <br />PLUG <br />BRONZE FL. PL. <br />OR WALL <br />SEE SPEC. <br />I'-8•X8' CONC. <br />BRASS PLLrO <br />FIN. GRADE <br />OR PAVING <br />�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION TO SOIL <br />OR UA4STE AS <br />WADE 8240-K JOSAM 560" <br />REQUIRED <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />CAULK <br />P.VC OPTI/SPEC <br />vFLOOR SLAB CLEAN -OUT (TYPN vEXT. GROUND CLEAN -OUT (T <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL32750 <br />PH: 407-774E078 <br />FAX 407-774-4078 <br />www.abdesigngroup.com <br />AA is 0003325 <br />L <br />TING 8Y: <br />IGN GROUP <br />TING INC. NTER BLVD. <br />4 <br />336342628 <br />2.2 <br />BXMDIV. & HAT: <br />SILVERADO <br />LOT #16 <br />BLK #14 <br />PR <br />OJECT# <br />03719,000-16141 <br />MOREZ, <br />2795-B <br />GARAGE aJ WWG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 PH EXP. B <br />