My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7298 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7298 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:36:12 PM
Creation date
2/19/2025 11:19:59 AM
Metadata
Fields
Template:
Building Plans
Street #
7298
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1988
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS 614ALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 101 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMMEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOVERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, &HALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS &HALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />I. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK. <br />1 <br />BALANCING DAMPER OR OBD <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRI AIR GRILL <br />FLR BELOW <br />-----------------� <br />I 1 <br />I I <br />I I <br />I i <br />I I <br />I I <br />t I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />t FLR BELOW <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE: I/4'.I'-0' <br />A R C N I T E C T I <br />6 <br />Groin <br />1441 N. RONALD REAUAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />W w W.abdesigngrou pxom <br />AA 0: 0003325 J <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />6439 BEAUMONT CENTER] <br />ENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLOMDA 33634 <br />PH: 813886-2628 <br />FAX: 813S862802 <br />�IIIIIIINI <br />�IIIIIIIIIE <br />SSUDDIV. de MP <br />SILVERADO <br />LOT# 5 <br />BLK# 15 <br />PROJECT* <br />03719.001-05151 <br />MODET- <br />JORDYN <br />GARAGE ISTIMCk <br />RIGHT <br />PAGE: <br />SECOND FLOOR <br />MECHANICAL <br />PLAN <br />150 . C <br />ob <br />nwTEi 03/02/21 <br />SCALE: AS NOTED <br />S ET <br />M2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.