My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7338 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7338 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:09:31 AM
Creation date
2/19/2025 11:23:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7338
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1986
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br />HVAC NOTES <br />MECHANICAL PLAN <br />SCALE, 1/4 . P-0' <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG, REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED ALAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATINGG, ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC ITN EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BAT14M FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1T14 EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />% ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1T14 <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRWK <br />BROKEN LINE- RETURN TRUNK <br />I <br />BALANCING DAMPER OR OBO <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />(1) <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />AIR RETURN SECURE STTRAAP TAPGONS <br />C�UNIIT R <br />T <br />1 <br />WB ROLL STRAP <br />SUCTION AND LIQUID <br />Di EQUAL <br />OR <br />AIR SUPPLY <br />b <br />REFRIGERANT LINES <br />N <br />AIR HANDLER <br />EXTERIOR WALL <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ (2) <br />"8XI 114' SHT. MTL. SCREWS <br />'PVC CONDENSATE DRAIN LINE <br />CONDENSER <br />UNIT <br />EVAP. TRAY <br />yLEEVE <br />TO LIDS BELOW SLAB <br />TREFRIGERANT <br />N <br />LESTO <br />CONNECTION <br />TO PAD <br />PLATFORM <br />RETURN <br />VCONDENSINGUNIT <br />NOTE: MAIN COND. DRAM 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD s 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL SLOG. CODE <br />SECTION W12A <br />HVAC <br />DRAINS <br />COLNTERSLW <br />SCORIATED NICKEL <br />FIN. FLOOR <br />CA. PLUG <br />BRONZE FL. PL. <br />OR WALL <br />I'_6• <br />SEE SPEC. <br />i0 <br />r-8'x8 CONC. <br />BRASS PLUG <br />FIN. GRADE <br />OR PAVING <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION TO SOIL <br />OR WASTE AS <br />WADE 8240-K JOSAM 56000 <br />REQUIRED <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />CAULK <br />P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYPN NEXT. GROUND CLEAN -OUT (T 5 <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdeslgngroup.com <br />AA#: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONf CENTER BLVD. <br />SURE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8138BS-2628 <br />FAX 813ZW2802 00 <br />U9UDDIV ee I.OT: <br />SILVERADO <br />LOT #2 <br />BLK 15 <br />PROJECTo <br />03719.001-02151 <br />MODEL <br />2795-CAMDEN <br />GARAGE STifMC;: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 PH EA H ol <br />