My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7740 Davie Ray Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7740 Davie Ray Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:37:54 PM
Creation date
2/19/2025 11:55:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7740
Location
Davie Ray Dr
Contractor
DR Horton
Building Plans - Permit #
689
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAUCER ROD <br />BACKER ROD <br />WRB LAYER M, <br />STUCCO WRAP <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />L BOTTOM. 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,Ys' CAULKING a JOINT <br />ALL AROUN <br />PER SECTION R703.7 <br />Eldelfor I ftw and olae0e M <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRD LAYER 12, FORTIFIDER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ...... <br />- - <br />BUILDING PAPER) <br />METAL LATH x-x-x-x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.1.1 / ASTM C-641-09, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEI <br />VERIFY LC <br />STUCCO <br />FINISH <br />b' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />b' SELF ADHEBIVE— <br />FLASHING (INSTALL <br />PER MANUF, SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.Th. <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAQ <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT Al <br />JOINTS AND <br />NTERSECTIG <br />STEP #1 <br />STEP *3 <br />�yPIZ <br />WOOD SHEATHING <br />Wift LAYER h, <br />STUCCO WRAP <br />WRD LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.G MAX <br />V TOIi' MID -Wei , <br />mn� ar.r�n <br />b' WIDE STRIP SELF <br />ADUGSIVE FLAMING, CLEAN <br />MASONRY BEFORE APPLYING; <br />�'- FINIM • MASONRY <br />(�4 HORIZONTAL WEEP SCREED <br />FRAME TO BLOCK) <br />8' <br />WRB LAYER at, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WM LAYER <br />h <br />STEP #2 <br />WRB LAYER 7, <br />STUCCO WRAP <br />APPLY 60 MIN <br />INGG <br />GRADE 'D' FELT <br />MEMBRANE <br />MEMBRANE FLASHING <br />FL4 <br />OVER <br />SELF-ADHERNG <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />U LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />STEP 1*4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #S STEP #(o <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH: 407-77"078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA e: O003328 <br />74 <br />� <br />gs� <br />b <br />m <br />ill <br />BUBDIV. ae LOT <br />ABBOTT PARK <br />LOT #18 <br />BLK #10 <br />PROJECT111 <br />04181.000-18101 <br />MODELe <br />4EBB <br />"1828-CALI" <br />GARAGE BVfMO: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />a <br />R07/29/201/4"=1'-0" <br />A2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.