My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7740 Davie Ray Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7740 Davie Ray Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:37:54 PM
Creation date
2/19/2025 11:55:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7740
Location
Davie Ray Dr
Contractor
DR Horton
Building Plans - Permit #
689
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER F5C 6TH EDITION (20I1) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 01 CLASS 1 AIR DUCT AS PER NFPA WA 2-3.1 <br />4. PRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY C 4IMhEY OR VENT <br />CUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, WALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO POO 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />5. ALL FIRE RATED CEILINGS AND WALLS SMALL HAVE AN APPROVED FIRE OR FIRE/SP10KE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (20Pi) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />AIR SUPPLY <br />AIR HANDLER <br />EVAP.TRAY <br />SCORIATED NICKEL <br />BRONZE FL. PL, <br />BRASS PLUG <br />INSIDE <br />CAULK <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />1010 <br />EXTERIOR WALL <br />T d <br />AIR RETURN <br />SUCTION AND LIQUID <br />1 <br />REFRIGERANT LINES <br />1 <br />EXTERIOR WALL <br />1 <br />3/4' PVC CONDENSATE ORAN LINE <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />RETURN <br />CONDENSING WIT <br />TRAP ORAN LINE AND TERMINATE <br />_ <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />FN. FLOOR <br />OR WALL <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM D60M <br />SERIES NICKEL BRASS TOP <br />P.V.G OP'TI/SPEG <br />FLOOR SLAB CLEAN -OUT (TYP <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAFCONB UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO IT W/ (2) <br />#SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAN CONO. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />(g)EXT. GROUND CLEAN -OUT (TYN <br />■ <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL 15E INSTALLED AT OR <br />ABOVE F.P,E. ELEVATION <br />MECHANICAL PLAN <br />SCALE: 114 - I'-0' <br />1441 N. RONALD REAG.AN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />L AA M: 0003325 J <br />F <br />gg <br />gbk <br />6 <br />'-�kko <br />a <br />gtmDiV ae L074 <br />ABBOTT PARK <br />LOT #18 <br />BLK #10 <br />PROJSCTdi <br />04181.000-18101 <br />MODrtr <br />4EBB <br />"1828—CALM" <br />OARAO2S STIIINO: <br />LEFT <br />PAO= <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />
The URL can be used to link to this page
Your browser does not support the video tag.