—LE END <br />HP RDDF�1' <br />ROOF WIND DESIGN PRESSURES <br />NET (GROSS) ASCE7-10 <br />ZONE 1 = 23.79 PSF (3379) <br />ZONE 2 : 39,48 PSF (49:48) <br />ZONE 3 = 67.16 PSF (77.16) <br />'A'= 4'-0' END ZONE DISTANCE <br />BASIC WIND SPEED: ISO MPH <br />WIND EXPOSURE: -C' <br />RISK CATAGORY: II <br />APPLICABLE INTERNAL <br />PRESSURE COEFFICIENT +-0.18 <br />ROOF DIAPHRAGM <br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/16' <br />O.S.B. OR 1/2' COX EXT. PLYWOOD, FOR <br />CEMENTITIOUS TILE AND METAL ROOFING, USE <br />MIN. 5/8 COX EXT. PLYWOOD, WITH 8d RING <br />SHANK GUN NAILS AT 4' O.C. AT SUPPORTED <br />PANEL EDGES AND 8d RING SHANK GUN NAILS <br />AT 6' O.C. AT INTERMEDIATE SUPPORTS, SEE <br />DETAIL. <br />ROOF SHEATHING TO GABLE END FRAME USE <br />8d GUN NAILS 0 4' O.C. EDGEWISE 2x4 <br />BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE <br />END. <br />ROOF/ WALU FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL SCHEDULE <br />SIZE <br />TYPE <br />MIN. LENGTH <br />MIN. DNA. <br />SHANK <br />TENSILE STR. <br />SHANK <br />8d <br />RING SHANK, <br />2 1/2' <br />0.120" <br />170,000 <br />RING <br />(18.20 RINGS <br />SCREW SHANK <br />PER INCH) <br />8d <br />SCREW SHANK <br />21/2" <br />0.120" <br />PNEUMATIC <br />SCREW -NAILS <br />1, NAIL SIZE PER ASTM F1664 <br />2. INTERNATIONAL STAPE, NAIL & TOOL <br />ASSOCIATION (ISANTA) ESH-1539 <br />EXTERIOR SHEATHING <br />USE 1/2' COX OR 7/16' O.S.B. PLY WITH Sd RING <br />SHANK GUN NAILS AT 4' O.C. AT PANEL SIDES <br />AND Sd RING SHANK GUN NAILS 4' O.C. TOP & <br />BOTTOM PANEL AND 8d RING SHANK GUN <br />NAILS AT WO C. <br />O.C. AT INTERMEDIATE SUPPORTS <br />OR 7/16' ZIP SHEATHING SYSTEM (INSTALLED <br />PER MANUR SPECS.) SEE DETAIL. <br />8d RING SHANK GUN NAILS G 4" O.C. <br />.. TOP & BOTTOM EDGES .- <br />Z <br />O <br />O W . <br />Z = <br />U <br />O <br />2 m <br />p <br />N <br />—1 <br />Z . <br />Z . <br />M <br />Y <br />a <br />ro <br />z <br />a <br />Z Z LN <br />2 p <br />3L� w <br />w0®6iM <br />U F U <br />w O <br />w tO <br />a <br />TOP CORD BLOCKING AT 4' <br />O.C. MAX. IN FIRST 2 FRAMING <br />SPACES AT EACH END. <br />O <br />RAFTER OR TRUSS � <br />ROOF SHEATHING —� <br />=MOM= 11 <br />. . <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL BRACING <br />FOR GABLE END FRAMING <br />- 8d RING SHANK GUN NAILS <br />O 6'O.C. IN FIELD <br />8d RING SHANK GUN NAILS 0 12' O.C. IN <br />FIELD or Sd X 2 1/2' SCREW SHANK <br />PNEUMATIC SCREW -NAILS 0 12' O.(i+l(J <br />FIELD J\ <br />TYP. 3l4' T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />GENERAL NOTES: <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND <br />ARCHITECTURAL, MECHANICAL., ELECTRICAL, PLUMBING AND S1TE DRAWINGS. CONSULT <br />ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 20W, StN EDITION <br />AC1318-14, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, ACI 630-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10AND AISC SPECIFICATIONS <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD, DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE 13RQUGHT <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />OF THE WORK <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE -DOWNS. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />REQUIREMENTS AND SLAS-ON-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR <br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />DESIGN LOADS: <br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psi <br />20 psf TOP CHORD-rallHbrlcurrant <br />10 psi BTM CHORD -ppn-ConcDrregt <br />DEAD LOAD DEAD LOAD <br />1& PH TOP CHORD 20 pst TOP CHORD <br />(7 psi w/ ASPHALT SHINGLES) (10 pef W/ No GYPCRETE) <br />10 ps1 BTM CHORD 5 psl BTM CHORD <br />DEAD LOAD TO RESIST WIND UPLIFT: 1OPBt <br />BALCONY LIVE LOAD 80 pV <br />STAIRS LIVE LOAD 40 pst <br />WIND: DEAD LOAD SPEED. 160 MPH3-SECOND GUST <br />(ASCE 7-10 (FBC R2017) EXPOSURE Q RISK CATEGORY II) <br />LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10Pef, UNINHABITABLE ATTIC WITH LIMITED <br />STORAGE: 20Pe1, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30paf, BALCONIES (EXTERIOR) <br />AND DECKS: 40pst, GUARDS AND HANDRAILS: 200psf, GUARD INFILL COMPONENTS: 50pef, PASSENGER <br />VEHICLE GARAGES: WPM. ROOMS OTHER THAN SLEEPING ROOM: 40pst, SLEEPING ROOMS: 30psf, STAIRS: <br />40pst <br />SHOP DRAWING REVIEW: <br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. <br />DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN <br />WRITING BY THE ARCHITECT. <br />FOUNDATK)W SITE PREPARATION: <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000pd FOOTING <br />EXCAVATIONS AND SLAB SUBARADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 06% OF THE <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM 0.1667. TREAT ALL <br />SOIL FOR TERMITE PROTECTION. <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE <br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL <br />BE MADE BY THE GEOTECH. ENGINEER. <br />CONCRETE: <br />CONCRETE SHALL ACHIEVE MINIMUM 2B DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />2,600 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5 " STRUCTURAL TERRACE SLAB. <br />CONTRACTOR SHALLSUBMT PROPOSED MX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MX PRIOR TO <br />CONCRETE PLACEIAEM. CONCRETE SLUMPSHALL NOT EXCEED 5' d-PRIOR TO THE ADDITION OF PLASTOM <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM CM. MAXIMUMAGGREGATE Siff SHALL BE 3111. <br />PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER <br />ALL EXPOSED EDGES OF CONCRETEARE TO BE CHAMFERS) Yr <br />PROVIDE 6411L CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SUIB9-01,14ROMA WHERE INDICATED ON <br />DRAWiNG6. SEAM LAPPED 6INCIES AND SEALED WITH AOFESNE TAPE <br />FORM -WORK: <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347, <br />'RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. <br />EXCLUSIONS FROM THESE PLANS: <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURALDEPENDING <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. <br />WELDED WIRE MESH: <br />WELDED WIRE MESH, SHALL BE ASTM AT85, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE ACI <br />TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE <br />SUPPORTED WITH 2' CHAIRS SPACED Y-T OC, EACH WAY. <br />REINFORCING STEEL: <br />REBAR SHALL BE ASTM A616 GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A816 <br />GRADE W IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE <br />W/ THE TYPICAL SENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. <br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL <br />AND VERTICAL BARS SHALL LAP 6x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS <br />REVIEW. <br />TYP. MIN LAPS SHALL BE AS FOLLOWS: "BAR - 25' #6 BAR - 36' <br />$5 BAR - 30' 07 BAR - 42' <br />PROVIDE 3W x 36' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />FOR ADDITIONAL INFORMATION. <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH <br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE <br />WALL, <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />WITHOUT THE APPROVAL OF THE ENGINEER. <br />MASONRY: <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE <br />'SPECIFICATION MASONRY STRUCTURES' (ACI 630/ ASCE S/TMS 402, BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS <br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE, <br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE Pm - 1500 PSI. BLOCK SHALL BE PLACED USING <br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH <br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 30DO PSI AT 28 DAYS, UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN, THE GROUT MIX SHALL HAVE A MAXIMUM 3/8' <br />COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8' TO 10'. USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />TYPE 'M' OR'S' MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />PROPORTIONED AND MIXED AS OUTUNED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />SHALL BE 3/B' THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />CELLS TO BE FILLED, <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL <br />REINFORCING. <br />LAP VERTICAL REBAR 6 X BAR NO, (48 BAR DIAMETERS)., U.N.O. <br />STRUCTURALSTEEL: <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM <br />ASS, Fy - 36 MI FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM A-600, GRADE B, <br />Py - 46 ksi. STRUCTURAL PIPE SHALL BE ASTM-53, GRADE B, TYPE E OR S, Fy . 36 kel . TUBE AND PIPE <br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL <br />OTHER BOLTS SHALL BE ASTM A326-N BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL <br />BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. <br />CONCRETE SHALL COLDLY WITH ALL THE REOUIREME NTS OF ACI 301 AND ASTM C44 OR MEASURING, MXING, TRANSPORTING ETC. ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. <br />CONCRETETICKETS SHALL BETIMESTAM PEDVMEN CONCRETE IS BATCHED. THE MAXIMAL TIME ALLOWED FROM WHEN WATER IS <br />ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MNITES IF FOR ANY REASON THERE IS A <br />DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE <br />RESPONSIBIUTY OF THE TESTING LABORATORY TO NOTIFY THE OVMERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON <br />COMPLIANCE WITH THE ABOVE. <br />REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: <br />A. 3' FOR CONCRETE CAST AGAINST AND PERMWENRY EXPOSED TO EARTH (FOINJDATIONS� <br />B. FOR CONCRETE EXPOSED TO EARTH ANDIORWEATHER, <br />1.1/2' FOR A8 AND SMALLER <br />7 FORd6 AND LARGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />314-FOR SLABS, WALLS AND JOISTS <br />1-1/C FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS <br />WOOD: <br />NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. <br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb - 1100 PSI AND A MODULUS OF <br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES <br />SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCP OF A BORATE PRESERVATIVE TREATMENT: DISODIUM <br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED <br />W/ DOT SHALL BE HOT DIPPED GALV, FOR STRUCTURAL USES AVOID BUYING TREATED LUMBER THAT <br />CONTAINS MORE THAN K' OF HEARTWOOD. <br />MINIMUM NAILING PER FSCR 2017, 61h EDITION. SEE NAILING SCHEDULE ON PLANS <br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />SYP 02. <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />WOOD TRUSSES: <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATIONS FOR <br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REOUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14,'DESIGN NATIONAL <br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND TPI/WTCA BCSI 1' <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING. INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI ASSA-1982. <br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. <br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />DETERMINATIONS, FEASIBILITY &ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LAYOUT, SPANS &ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />LICENSED PROFESSIONAL ENGINEER. <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7.10 COMPONENT <br />AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK <br />FASTENER <br />FASTENER <br />APNILATgN <br />8RE <br />tYPE <br />SPACMD <br />RENARK9 <br />APPIICgTKW <br />gDF <br />TYPE <br />SPACMO <br />REMAfMS <br />1x2 PT NRRMO TO <br />CABEHARDENEDCOx <br />OM/d3E Wpq BUCK <br />1N'DLl <br />TAPClx1 MABWRY <br />1tlY EMBED..4'ENO DIST„ <br />MABONRYIOONC. <br />NAL 112IO <br />BQC <br />..ASONRTIC . <br />NO WASHER <br />FASTENER <br />BO'C <br />f,?FOIE OFiT. <br />&10�AL. ExT. CCOR4 <br />CASE HARpENEDOOI <br />B'OC <br />WINOOWN00F FfSTENED <br />OMAOE DJOR &1CK <br />tIY DMA. WI <br />A'EM�D., t' ENDOIST., <br />x ,BEE VIOLET <br />WAR, I?Lap. <br />BTADOEAW <br />MTO MAFOFMYMANC. <br />TOMABONNYIC , <br />WAg R <br />EXPANSION B0.T <br />b.� <br />B'EDOE OLgT. <br />WMOOWBLCK <br />CABEHAPDENEDCOIL <br />B'OC <br />WMDOWpOaLFABTENED <br />METAL9TRAPro <br />CONTACT THIS ENGINEER <br />FOR SPACING <br />,x PT, BEF NOtEB <br />NAx „4 Lap. <br />gTAMERED <br />NTOMASONRYICCMC, <br />MASONRYIc— <br />REQUIREMENTS <br />XT.SWNO pOON <br />(2I8NYDL1. <br />'TAPOOM <br />IB OC <br />tl?EMBED.B END. <br />Ndi.BEAFMp W00D <br />,I1^ EXP—N 4•EMBED. 4'ENO <br />440L LDIET. <br />BUCK91 T,9EE NOTEB <br />NO WgSHER <br />FASRIER <br />05T„11?EOOE GIST. <br />WALL TO COIL. SLAB <br />W/WASHER BOLT DST.,e' <br />.PT WINWW 9B°PAFxYIAt' B'OC 4'END. DMT.,I t? <br />ro gTEEICOI-gEE IWyW,��R giAO0ERE0 EDGE qgi. <br />NOTE B <br />11. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURERS SPECS AND / OR NGA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4, PAF SHALL BE HILT] X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />8. WINDOW AND DOOR BLACKS SHALL BE A3 WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. 1x MEMBERS ARE NAILED AND <br />2z MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE. <br />i44i N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH:407.774.6078 <br />FAX: 407-774.4078 <br />www.abdeslgngroup.com <br />AA N: 0003325 <br />q <br />a <br />Z <br />Ys <br />W <br />b� <br />GI <br />GI <br />4 <br />SVSDM AC LOT <br />ABBOTT PARK <br />LOT #16 <br />BLK #10 <br />PROJECTN/ <br />04181.000-16101 <br />HODELm <br />4EBB <br />"1828-CALL" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />DETAILS <br />160 MPH EXP. C <br />