INSTALL ro' SELF -ADHERING <br />MEMBRANE FLASHING OVER STUCCO <br />TOP, SIDE(S) AND BOTTOM FINISH <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. (ol SELF ADHESIVE M WOOD CONSTRUCTION <br />SEQUENCE OF: FLASHING TO BE: <br />OVER TOP 4 SIDES <br />I. BOTTOM, 2. SIDES, 3. TOP KM <br />X VENT CAP 15 TO BE SET IN BED SELF WOOD SHEATHING WOOD SHEATHING <br />OF SEALANT AT TOP AND WRB LAYER 01, <br />FLASHING <br />X SIDES ONLY. SEALANT 16 TO BE WR5 LAYER 01, STUCCO WRAP <br />UNIT <br />WRB LAYER 02, FORTIF15ER <br />TOOLED 60 AS TO DEFLECT <br />STUCCO WRAP <br />WATER AWAY FROM JOINTS. <br />BUILDING PAPER <br />PREMANUF. DRYER <br />X E-Z BEAD ALL AROUND <br />METAL LATH <br />VENT CAP (SET IN <br />VENT -APPLY SEALANT ALL <br />WR5 LAYER w2, FORTIF15ER <br />X JOINTS AND INTERSECTIONS CONT. SEALANT) <br />WOOD -1/8' TEXTURED <br />BUILDING PAPER CONSTRUCTION FINISH a WOOD <br />APPLY SEALANT AT PERIMETER OF 5 <br />BACKER ROD ti <br />NON -MOVABLE FRAME AND STUCCO FASTEN TO WOOD STRUCTURAL <br />ON ALL SIDES, y4' CAULKING JOINT MEMBER 0 12 O.C. MAX <br />SEALANT ID <br />a, CMU <br />ALL AROUND THICK, -3 COAT CEMENT <br />TOP 4 SIDES <br />PLASTER Ya"TO)J1 MID -WALL <br />1. <br />PER SECTION R703.7 WEEP SCREED <br />Exterior lathing and plastering <br />rL <br />BACKER ROD Exterior use of portland cement plaster <br />DRYER VENT (BLOCK) TO MID -WALL <br />shall comply with the application <br />6 WEEP SCREED <br />X. requirements of ASTM C 926-12A. <br />F <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />X Installation of exterior lathing and framing <br />MASONRY BEFORE APPLYING <br />shall comply with ASTM C 1063-12A. <br />6" SELF-ADHESIVE <br />TEXTURED <br />WRB LAYER 01, <br />FLASHING <br />FINISH MASONRY <br />STUCCO WRAP <br />HOODED VENT BUILDING PAPER <br />OVER QUICK WOOD FRAMED <br />HORIZONTAL WEEP SCREED <br />THICK, 3 COAT CEMENT FLASH' WALL <br />PLASTER (FRAME TO BLOCK) <br />METAL LATH HORIZONTAL WEEP SCREED <br />WRB LAYER 02, FORTIF15ER PIPE THROUGH (FRAME TO FRAME) <br />BUILDING PAPER WALL <br />WOOD SHEATHING <br />DRYER VENT (FRAMEJ <br />6 ro' SELF ADHESIVE <br />FLASHING NNSTALL­_N'__� <br />PER MANUF. SPECS.) all <br />BUILDING PAPER <br />WOOD SHEATHING UNDER 'QUICK FLASH"WRB LAYER 01, <br />WRB LAYER 01, <br />CUT OPENING IN STUCCO WRAP <br />STUCCO WRAP <br />APPROVED HOUSEWRAP <br />,,—WR5 LAYER 02, FORTIF15ER FOR 50X INSTALLATION <br />............ <br />BUILDING PAPER <br />WOOD <br />CUT "X' INTO <br />CONSTUCTION <br />WRB LAYER 01, SELF -ADHERING <br />VENT PENETRATION; <br />�AT �IO N� <br />STUCCO WRAP MEMBRANE FLASHING <br />METAL LATH <br />SCALEN.T.S. <br />f.2 <br />a, CMU <br />VINYL CASING BEAD APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />6' RAISED BAND <br />WOOD SHEATHING <br />OVER 50X AND OVER <br />Yell TO,�' MID -WALL APPROVED WRB LAYER <br />WEEP SCREED <br />e a5TEP 1*1 STEF *12 <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING APPROVED <br />Z FLASHING HOUSEWRAP <br />BELOW WRB LAYER 01, <br />STUCCO WRAP <br />ELEC. METER FIELD <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />STONE VENEER 10— SELF -ADHERING <br />OVER SCRATCH COAT VERIFY LOCATION CUT SUCH THAT APPLY 60 MIN <br />MEMBRANE FLASHING <br />NO MEMBRANE GRADE 'D' FELT <br />ENTERS 50X, OVER <br />APPLY TO FACE SELF -ADHERING <br />APPLY STUCCO SCRATCH COAT .......... <br />EDGE FLASHING OVER <br />AFROVED <br />HORIZONTAL WEEP SCREED AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. HOUSEWRAP <br />/STONE VENEER <br />METER WRB LAYER w2, FORTIF15ER <br />(FRAME TO BLOCK) • CAVITY TO BE FILLED &TEF #3S <br />BUILDING PAPER <br />WITH RIGID POLYMERIC TEF #4- <br />ISOCYANOTE-POLY5LEND FOAM <br />LEGEND- ("GREAT STUFF" OR SIMILAR) <br />ELASTOMERIC <br />APPLY A SILICON <br />...... COATING OVER <br />DRAINAGE PLANE (Wf;R5 BASE SEALANT AT POINT <br />77 STUCCO/ C.V. FINISH <br />LAYER *'I, STUCCO WRAP) THAT ELEC. WIRE PENETRATES (SEE TYPICAL WALL <br />APPLY E-Z BEAD <br />SECTION) <br />OVER 60 MIN 00 <br />WR5 LAYER *2 (FORTIFBER ...... GRADE 'D a 00 METAL LATH <br />AREA TO RECEIVE FELT -PROVIDE <br />5UILDING PAPER) <br />STUCCO SCRATCH COAT SEALANT AT ALL 00 <br />1 COAT OF PAINT W/5AC<- JOINTS AND 0 <br />METAL LATH X—X—X—x 00 <br />INTERSECTIONS 00 .0 0 <br />ROLL PRIOR TO •0 0 0 0 <br />ELEC. METER INSTALLATION <br />STUCCO _PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />WOOD SHEATHING METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />SELF-ADHESIVE FLASHING DISCONNECT ST E F ST E F <br />NOTE: ELECTRICAL RECEPTACLE <br />METAL LATH: LATH TO BE PER SECTION ELECTRICAL CONDUIT 9 <br />Z_7 <br />X X X k, <br />R103.1.1 A6TM G-541-0'3/ MIN. 2.5 L55. 8 PENETRATION <br />PER Sa. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />8 <br />8 <br />P 'j <br />H: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />C, <br />o>1 <br />e <br />A <br />� <br />A <br />c <br />4 <br />SUBDIV. & LOT: <br />ABBOTT PARK <br />LOT #34 <br />BLK #9 <br />PROJECT# <br />04181.000-34091 <br />MODEL: <br />3EAB <br />15 0 4 - ALLE X" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP . C <br />i r, LISA." JL <br />DATE: 05/26/20 <br />SCALE: 1/4"= ill— 0 it <br />SHEET <br />