My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7763 Davie Ray Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7763 Davie Ray Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:02:39 AM
Creation date
2/19/2025 12:30:36 PM
Metadata
Fields
Template:
Building Plans
Street #
7763
Location
Davie Ray Dr
Contractor
DR Horton
Building Plans - Permit #
384
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1, <br />ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />125V OUTLET <br />20 AMP SINGLE POLE <br />110V OUTLET <br />IIOV OUTLET <br />1/2 OF OUTLET WIRED <br />TO SWITCH <br />GFI <br />IIOV OUTLET <br />EGiUIPED W/GRND FAULT <br />INTER+IPTER (TAMPER <br />RESISTANT TYPE) <br />220V OUTLET <br />(4) WIRE CONNECTION <br />GROLM T <br />GFI <br />OUTLET <br />INTERRUPTER <br />SWITCH <br />SWITCH <br />3-WAY OPER <br />!�4 <br />SWITCH <br />4-WAY OPER <br />WALL MOUNTED <br />LIGHT <br />CEILING LIGHT <br />O <br />LED CLG LIGHT <br />O 1/P <br />LED VAPOR <br />PROOF LIGHT <br />O VP <br />VAPOR PROOF <br />LIGHT <br />ORECESSED <br />CAN <br />VENT. FAN <br />I CFM PER SQ. FT. <br />VENT, FAN <br />W1L IGHT <br />Q. I CFM PER SFT. <br />VANITY LIGHT <br />FIXTURE <br />(SPEC'S TBD BY <br />BUILDER) <br />FLUORESCENT <br />LIGHT <br />2-BULB WRAP <br />AROUND <br />(RECESSED) <br />FLUORESCENT <br />LIGHT <br />2-5ULB WRAP <br />AROUND <br />(SURFACE MNT.) <br />2' FLUORESCENT <br />4' FLUORESCENT <br />4' TRACK LIGHT <br />PANEL <br />OWN <br />METER <br />OSMOKE <br />S.D. <br />DETECTOR <br />BAIT. BACK-UP <br />w/ HARDWIRE <br />WALL MOUNTED <br />BATT, BACK-UP <br />S D <br />SMOKE DETECTOR <br />W/ HARDWIRE <br />® S/CO <br />CARBON MONOXIDE <br />8" 1OKE DETECTOR <br />BATT, BACK-UP W/ <br />HARDWIRE <br />INTER -CONNECTED <br />COMBO <br />SHALL BE A DISTANCE <br />OF NOT LESS THEN 4' <br />FROM WALL <br />PENDANT LIGHT <br />NATURAL GAS <br />OUTLET <br />TELEPHONE JACK <br />WATER HEATER <br />IGNITION SOURCE <br />TO BE ELEVATED <br />DISCONNECT <br />A/C <br />AIR CONDITIONING <br />TO SEE E 21 ONU'�' <br />DISCONNECT <br />THIS SWEET <br />TY <br />TELEVISION JACK <br />CEILING BOX REQUIRE <br />OJ-BOX <br />TO BE SUPPORTED IN <br />ACCORDANCE W/ BOX <br />MARKED AS SUCH FOR <br />INSPECTION <br />CEILING BOX REQUIRE <br />TO BE SUPPORTED IN <br />CEILING FANLIGHT <br />ACCORDANCE W/ BOX <br />MARKED AS SUCH FOR <br />INSPECTION <br />24' INCANDESCENT <br />LIGHT STRIP <br />36' INCANDESCENT <br />LIGHT STRIP <br />48' INCANDESCENT <br />LIGHT STRIP <br />FLOOD LIGHT <br />OPT. SECURITY <br />KEYPAD <br />P$. <br />PUSH-BUTTON <br />FOR CHIMES <br />�—�-► <br />USB PORT <br />• LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO <br />BE VERIFIED • HOMEOWNER PRE -CONSTRUCTION <br />MEETING. <br />s ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT <br />PROTECTED PER ELECTRICAL PROVISIONS OF FBCR <br />6TH EDITION (2011) 4 NEC 210.12 2014 EDITION. <br />* 20 AMP DEDICATED LAUNDRY CIRCUIT. <br />* GFI 0 ISLAND (NOT ON KITCHEN CIRCUIT) <br />• DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL <br />* BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF <br />50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF <br />SECTION M15013 FBCR 6TH EDITION (2011). <br />• LAUNDRY ROOM RECEPTACLE SHALL BE GROUND <br />FAULT CIRCUIT -INTERRUPTER PROTECTION FOR <br />PERSONNEL ON FEEDERS <br />• WIRING METHOD SHALL BE NON METALLIC CABLE PER <br />ELECTRICAL PROVISIONS OF FBCR 6TH ED (2011). <br />ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS <br />OF THE FBCR 6TH ED (2011). <br />• ALL LAMPS SHALL BE SELECTED BY BUILDER AND <br />1r2% OF LIGHTING MUST BE ENEFrxY EFFICIENT TYPE PER <br />F.B.C. ENERGY CONSERVATION (RESIDENTIAL ENERGY <br />EFFICIENCY) 2011. bth EDITION R404.1 <br />150 AMP ELECTRICAL RISER <br />NOT TO SCALE. <br />GENERAL NOTES: <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 6tH <br />EDITION (2011). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. <br />B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 01 COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE IS PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />I' <br />LED LIGHTING <br />C SINGLE LAV. <br />0 BATH *2 <br />PROVIDE 302/0 CU, THWN + 106 CU IN 2' CONDUIT OR 3 <br />04/0 AL, THWN + 1% CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT ® OVERHAWa.) <br />COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />M ELECTRIC METER IN 1 PHASE <br />NEMA 3R ENCLOSURE MLO <br />PANEL <br />150A/2P <br />MCB <br />TELEPHONE SERVICEI I I ICABLE TELEVISION <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />1 04 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR (otH <br />EDITION (2011). <br />5/8" DIA X & FT LONG COPPER CLAD GROUND ROD <br />PANEL: A <br />PANEL: 42 crt. breaker VOLTAGE: 120 / 240 V -1 Ph MAIN: 150 Amp M.L.O. <br />FEEDER: 3- #2/0 Cu THWN & 1- #6 Cu (G) in 2" C. OR 3- #4/0 AL THWN & 1- #6 Cu (G) in 2" C. <br />Wire <br />Pole <br />Bkr <br />I Description <br />Watts <br />I Circuit <br />Circuit <br />2 <br />I Watts <br />Description <br />Bkr <br />Pole <br />Wire <br /># 12 <br />1 <br />20 <br />ISmall Appliance <br />1500 <br />1 <br />8000 <br />Range <br />50 <br />2 <br />#6 <br /># 12 <br />1 <br />20 <br />1 Microwave! Hood <br />1800 <br />3 <br />4 <br />6 <br />#12 <br />1 <br />20 <br />Small Appliance <br />1500 <br />5 <br />4500 <br />Water Heater <br />25 <br />2 <br />#10 <br /># 12 <br />1 <br />20 <br />Refrigerator <br />1500 <br />7 <br />8 <br />10 <br />12 <br /># 12 <br />1 <br />20 <br />Dining Receptacles AFCI <br />1500 <br />9 <br />1200 <br />Disposal GFI <br />20 <br />1 <br />#12 <br />#12 <br />1 <br />20 <br />Bath GFI Receptacles <br />1200 <br />11 <br />1500 <br />Dishwasher GFI <br />20 <br />1 <br />#12 <br />#14 <br />1 <br />15 <br />Foyer / Hall <br />900 <br />13 <br />14 <br />5000 <br />Dryer <br />30 <br />2 <br />#10 <br />#14 <br />1 <br />15 <br />Great Room / Din. Light / Lanai AFCI <br />900 <br />15 <br />16 <br />18 <br />#14 <br />1 <br />15 <br />1 Kitchen Lights / Pantry i Drop AFCI <br />900 <br />17 <br />1500 <br />Washer GFI <br />20 <br />1 <br />#12 <br />#14 <br />1 <br />15 <br />1 Bed #2 / Laundry AFCI <br />1200 <br />19 <br />1 20 <br />1000 <br />Garage Door Opener GFI <br />20 <br />1 <br />#12 <br />#14 <br />1 <br />15 <br />Bed #3 / Bath #2 AFCI <br />900 <br />21 <br />1 22 <br />1200 <br />Garage / Exterior Lts & Recepts. AFCI <br />20 <br />1 <br />#12 <br />Space <br />23 <br />24 <br />26 <br />28 <br />900 <br />Owmer Bedroom/ SD's AFCI <br />15 <br />1 <br />#14 <br />Space <br />25 <br />900 <br />Owners Bedroom / W.I.C. AFCI <br />15 <br />1 <br />#14 <br />Space <br />27 <br />Space <br />Space <br />29 <br />30 <br />32 <br />Space <br />Space <br />31 <br />Space <br />Space <br />33 <br />34 <br />36 <br />Space <br />Space <br />35 <br />Space <br />c—'. <br />37 <br />38 <br />c„ '. <br />#B I 2 I 60 JA/C AHU-1 <br />(Heae10 KVA at 65% <br />Load subject to demand factor calculations / line <br />Demand Factor Calculations: <br />Total load subject to demand factor <br />First 10000 watts at 100% <br />Remaininq watts at 40% <br />9600 3a 4u 4400 A/C C.U.-1 40 1 #8 <br />41 42 N.C. <br />23400 30100 Load subject to demand factor calculations / line <br />53500 ABBREVIATIONS: <br />AFCI: ARC FAULT CIRCUIT INTERRUPTER <br />10000 NC: NON -COINCIDENT LOAD <br />17400 GFI: GROUND FAULT INTERRUPTER <br />/ \ Total Connected Load Watts 29140 LOAD CALCULATION IS BASED ON AfC NON -COINCIDENT LOAD <br />Total Amps (watts 1 240 volts) 121.4 <br />General Li htin & Receptacle Load <br />Total A/C Square Feet 150 <br />I I General Lts & Rec 3 W / Sq. Ft. 451 <br />Hi -Hats 19 at 65W/Li ht at 100% 123 <br />General 574 <br />/ C kts# tts/ck Tota I watts <br />\ _ General Lts & Rec Panel A 1 101 5751 574 <br />LED LIGHTING <br />C DOUBLE LAV. <br />OWNER'S BATH <br />ELECTRICAL PLAN, <br />FIELD NB <br />VERIFY <br />LOC. <br />OPT. <br />COACH <br />LIGHT <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />h <br />W <br />U <br />� <br />W <br />� <br />V <br />l7 <br />W <br />V <br />OG <br />d <br />o <br />0. <br />A <br />p <br />Q <br />dl <br />W <br />h <br />Q <br />ai+ <br />� <br />� <br />0 <br />A <br />� <br />0 <br />0 <br />0 <br />E4 <br />V <br />SUHDIV. & LOT: <br />ABBOTT PARK <br />LOT #34 <br />BLK #9 <br />PROJECT# <br />04181.000- 34091 <br />MODEL- <br />3EAB <br />"1504- ALLEY-" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />ELECTRICAL <br />PLAN <br />160 MPH EA Er C <br />ARCHITECT <br />STATE OF FLORIDA <br />
The URL can be used to link to this page
Your browser does not support the video tag.