11 <br />HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB i MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA SOA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (201-1) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />-I. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (201-1) MECHANICAL CODE SECTION <br />403. <br />6. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® SIDE -WALL OR 1 WAY DIFFUSER <br />SOLID LINE = SUPPLY TRUNK <br />BROKEN LINE = RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />O CEILING EXHAUST FAN <br />CEILING EXHAUST FAN d LIGHT <br />O/A OUTSIDE AIR <br />THERMOSTAT <br />m PASS-THRU AIR GRILL <br />SECOND FLOOR <br />MECHANICAL PLAN. <br />FREE DRAW AIR <br />HANDLER CLOSET <br />W/LOUVERED DOOR <br />SUPPLIED BY <br />BUILDER <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />7uLj-c,lm <br />W <br />> <br />n <br />a <br />144 <br />O <br />4 <br />N <br />J <br />Ck <br />w <br />U <br />N <br />N <br />N <br />v <br />A <br />w <br />u <br />w <br />pp <br />Q <br />w� <br />Cl.Q <br />ul <br />Q <br />Q <br />ol <br />A <br />0 <br />0 <br />A <br />0 <br />0 <br />c <br />SLTBDIV. & LOT: <br />ABBO TT <br />PARK <br />LOT #36 <br />BLK #9 <br />PROJECT# <br />04181.000- 36091 <br />MODEL: <br />3EFB <br />'2447-ROBIE" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />SECOND <br />FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH EXP. C <br />PRINT 05 26 20 <br />DATE: <br />SCALE: 1/41' <br />SHEET <br />M 2 <br />