Laserfiche WebLink
t <br />ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />—e <br />125v OUTLET <br />20 AMP SINGLE POLE <br />110V OUTLET <br />110V OUTLET <br />1/2 OF OUTLET WIRED <br />TO SWITCH <br />GFI <br />110V OUTLET <br />EITERUPQUIPED AULI <br />R (TAMFFND ER <br />INTERUPTER (TAMPER <br />RESISTANT TYPE) <br />220v OUTLET <br />(4) WIRE CONNECTION <br />—�i— <br />EXT. WATERPROOF <br />GROUND FAULT <br />-tf— 1 <br />OUTLET <br />INTERRUPTER <br />SWITCH <br />SWITCH <br />3-WAY OPER <br />�t4 <br />SWITCH <br />4-WAY OPER <br />WALL MOUNTED <br />LIGHT <br />CEILING LIGHT <br />O <br />LED CLG LIGHT <br />O VP <br />LED VAPOR <br />PROOF LIGHT <br />O VP <br />VAPOR PROOF <br />LIGHT <br />© <br />RECESSED CAN <br />® <br />VENT. FAN <br />I CFM PER SQ. FT. <br />VENT. FAN <br />W/L IGHT <br />I GFM PER SQ. FT. <br />VANITY LIGHT <br />FIXTURE <br />(OPEC* TBD BY <br />BUILDER) <br />TKIFLUORESCENT <br />LIGHT <br />2-BULB WRAP <br />AROUND <br />(RECESSED) <br />FLUORESCENT 21 <br />2-BULB WRAP <br />LIGHT <br />AROUND <br />(SURFACE MNT.) <br />2' FLUORESCENT <br />4' FLUORESCENT <br />4' TRACK L IGHT <br />0 <br />PANEL <br />METER <br />WATT. BACK-UP <br />OS.D. <br />SMOKE DETECTOR <br />W/ HARDWIRE <br />WALL MOUNTED <br />BATT. BACK-UP <br />$� <br />SMOKE DETECTOR <br />W/ HARDWIRE <br />® 6/CO <br />CARBON MONOXIDE <br />SMOKE DETECTOR <br />BATT. BACK-UP W/ <br />HARDWIRE <br />INTER -CONNECTED <br />COMBO <br />SHALL BE A DISTANCE <br />OF NOT LESS THEN 4' <br />FROM WALL <br />PENDANT LIGHT <br />NATURAL GAS <br />OUTLET <br />► <br />TELEPHONE JACK <br />W14 <br />WATER HEATER <br />IGNITION SOURCE <br />TO BE ELEVATED <br />DISCONNECT <br />A/ <br />AIR. CONDITIONING <br />TO SEE E 21 U.N.O. <br />DISCONNECT <br />THIS SWEET <br />TV <br />TELEVISION JACK <br />CEILING BOX REQUIRED <br />OJ-BOX <br />TO BE SUPPORTED IN <br />ACCORDANCE W/ BOX <br />MARKED AS SUCH FOR <br />INSMOTION <br />CEILING BOX REQUIRED <br />TO BE SUPPORTED IN <br />CEILING FANLIGHT <br />ACCORDANCE W/ BOX <br />MARKED AS SUCH FOR <br />INSPECTION <br />24' INCANDESCENT <br />LIGHT STRIP <br />n no <br />36' INCANDESCENT <br />LIGHT STRIP <br />48' INCANDESCENT <br />LIGHT STRIP <br />FLOOD LIGHT <br />OPT. SECURITY <br />KP <br />KEYPAD <br />P.B. <br />PUSH-BUTTON <br />FOR CHIMES <br />�—► <br />USB PORT <br />• LOCATION OF Tv JACKS 4 PHONE OUTLETS 4 FANS TO <br />BE VERIFIED 0 HOMEOWNER PRE -CONSTRUCTION <br />MEETING. <br />• ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT <br />PROTECTED PER ELECTRICAL PROVISIONS OF FBCR <br />6T14 EDITION (2011) 4 NEC 210.12 2014 EDITION. <br />• 20 AMP DEDICATED LAUNDRY CIRCUIT. <br />• GFI a ISLAND (NOT ON KITCHEN CIRCUIT) <br />• DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL <br />• BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF <br />50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF <br />SECTION M15013 FBCR 6TH EDITION (2011). <br />• LAUNDRY ROOM RECEPTACLE SHALL BE GROUND <br />FAULT CIRCUIT -INTERRUPTER PROTECTION FOR <br />PERSONNEL ON FEEDERS <br />• WIRING METHOD SHALL BE NON METALLIC CABLE PER <br />ELECTRICAL PROVISIONS OF FBCR 6TH ED (2011). <br />• ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS <br />OF THE FBCR 6TH ED (2011). <br />LAMPS SHALL SELECTED AND <br />• ALL BE BY BUILDER <br />lb% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER <br />F.B.C. ENERGY CONSERVATION (RESIDENTIAL ENERGY <br />EFFICIENCY) 2011. 6th EDITION R404.1 <br />METER <br />FIELD <br />VERIFY <br />LOC. <br />LIGHT <br />FIRST FLOOR ELECTRICAL PLAN_ <br />ALL BRANCH CIRCUITS REQUIRED <br />IN N.E.C. 210.52 ARE TO BE PROTECTED <br />BY AN ARC -FAULT INTERRUPTER LISTED <br />TO PROVIDE PROTECTION OF ENTIRE BRANCH CIRCUIT <br />GGFI <br />WP Panel MAIN - A <br />PANEL: 8/16 wp crt. breaker VOLTAGE: 120 / 24O V -1 Ph MAIN: 150 Amp M.C.B <br />FEEDER:3-#1 CuTHWN& 1-#6Cu(G)inl 1/2"C. OR 3-#2/OALTHWN& 1-#6Cu(G)in1 1/2"C. <br />Wire <br />Pole <br />Bkr <br />Description <br />Watts <br />Circuit <br />Circuit <br />Watts <br />6240 <br />Description <br />Space <br />Space <br />A/C C.U.-1 <br />Bkr <br />30 <br />Pole <br />2 <br />Wire <br />#10 <br />#12 <br />1 <br />20 <br />Exterior Receptacle GFI for TUG <br />1200 <br />1 <br />2 <br />#12 <br />2 <br />20 <br />Irrigation Pump <br />1000 <br />3 <br />4 <br />5 <br />6 <br />Space <br />7 <br />8 <br />PANEL -A <br />PANEL: 42 crt. breaker VOLTAGE: 120 /240 V -1 Ph MAIN: 150 Amp M.L.O. <br />FEEDER: 3-#1 Cu THWN & 1- #6 Cu (G) in 1 V2" C. OR 3-#2/0 AL THWN & 1- #6 Cu (G) in 1 1/2" C. <br />Wire <br />Pole <br />Bkr <br />Description <br />Watts <br />Circuit <br />circuit <br />2 <br />4 <br />6 <br />Watts <br />Description <br />Bkr <br />Pole <br />Wire <br />#12_ <br />1 <br />20 <br />Small Appliance <br />1500 <br />1 <br />8000 <br />Range <br />50 <br />2 <br />#6 <br />#12 <br />1 <br />20 <br />Microwave! Hood GFI <br />1800 <br />3 <br />#12 <br />1 <br />20 <br />Small Appliance <br />1500 <br />5 <br />4500 <br />Water Heater <br />25 <br />2 <br />#10 <br /># 12 <br />1 <br />20 <br />Refrigerator <br />1500 <br />7 <br />8 <br />#12 <br />1 1 <br />20 <br />Dining Receptacles AFCI <br />1500 <br />9 <br />10 <br />12 <br />1 1200 <br />Disposal GFI <br />20 <br />1 <br />#12 <br />#12 <br />1 <br />20 IBath <br />GFI Receptacles <br />1200 <br />11 <br />1 1500 <br />Dishwasher GFI <br />20 <br />1 <br />#12 <br />#12 <br />1 <br />20 1 <br />Foyer / Hall I Dining AFCI <br />1200 <br />13 <br />14 <br />16 <br />5000 <br />Dryer GFI <br />30 <br />2 <br />#10 <br />#14 <br />1 <br />15 <br />Kitchen, Living Room, Pantry Lights AFCI <br />900 <br />15 <br />Space <br />17 <br />18 <br />1500 <br />Washer GFI <br />20 <br />1 <br />#12 <br />#14 <br />1 <br />15 <br />SD & CIO AFCI <br />900 <br />19 <br />20 <br />1000 <br />Garage Door Opener GFI <br />20 <br />1 <br />#12 <br />#12 <br />1 1 <br />20 <br />Bed #2 & Bath #2 AFCI <br />1200 <br />21 <br />22 <br />24 <br />1200 <br />Garage/ Exterior Lts & Receptacles AFCI <br />20 <br />1 <br />#12 <br />#12 <br />1 <br />20 <br />Bed #5 & Bath #3 & Hall & Laundry AFCI <br />1200 <br />23 <br />900 <br />Owner's Suite AFCI <br />15 <br />1 <br />#14 <br />Space <br />25 <br />26 <br />900 <br />Owner's Bathroom AFCI <br />15 <br />1 <br />#14 <br />Space <br />27 <br />28 <br />1000 <br />Irrigation controls only <br />20 <br />1 <br />#12 <br />Space <br />29 <br />Space <br />Space <br />31 <br />Space <br />Space <br />33 <br />space <br />Space <br />35 <br />W40 <br />Space <br />Space <br />37 <br />Space <br />#8 <br />2 <br />35 <br />A/C AHU-1 <br />(Heater 5KVA at 65% <br />5525 <br />1411 <br />39 <br />Space <br />42 <br />Space <br />Load subject to demand factor calculations ! line 1 <br />16600 <br />26700 1 <br />Load subject to demand factor calculations / line <br />Demand Factor Calculations: <br />ABBREVIATIONS: <br />AFCI: ARC FAULT CIRCUIT INTERRUPTER <br />NC: NON -COINCIDENT LOAD <br />GFI: GROUND FAULT INTERRUPTER <br />Total load subject to demand factor 43300 <br />First 10000 watts at 100% <br />10000 <br />Remaining watts at 40% <br />13320 <br />Total A/C load <br />11765 <br />LOAD CALCULATION IS BASED ON AtC NON -COINCIDENT LOAD <br />Total Connected Load Watts <br />35085 <br />Total Amps (watts / 240 volts) <br />146.2 <br />General Lighting & Receptacle <br />Total A/C Square Feet <br />General Lts & Rec 3 W I Sq. Ft. <br />Hi -Hats 1 at 65WA i ht at 100% <br />Total General Lights & Rec (Watts) <br />General Lts & Rec Panel A 1 <br />Load <br />2447 <br />7341 <br />65 <br />7406 <br />Ckts# <br />watts/ckt <br />Totalwatts <br />8 <br />9261 <br />7406 <br />nl <br />Ir <br />o el —ON <br />o <br />nl <br />r <br />1 <br />1 <br />LED LIGHTING <br />C� SINGLE LAV.- <br />5ATH02 <br />150 At If= ELECTRICAL. R15E R <br />NOT TO SCALE. <br />GENERAL NOTES: <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 6tH <br />EDITION (2011). LOCAL CODES, AND ALL LOCAL POUTER <br />COMPANY REQUIREMENTS. <br />B. ALL CONDUCTORS SHALL BE TYPE TI- HN/THWN UNLESS <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, 1 PHASE SECONDARY <br />ELECTRICAL SERVICE. PROVIDE 3 01 COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE IS PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />PROVIDE 302/0 CU, THWN + 1% CU IN 2' CONDUIT OR 3 <br />04/0 AL, THWN + 1% CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE A50VE SOFFIT 10 OVERHANG.) <br />COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />ELECTRIC METER IN I PHASE <br />NEMA 3R ENCLOSURE MLO <br />M O <br />PANEL <br />150A/2P <br />MCB <br />TELEPHONE SERVICE <br />ENTRANCE <br />EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />CABLE TELEVISION <br />SERVICE ENTRANCE <br />EQUIPMENT <br />1 1*4 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 61H <br />EDITION (2011). <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />t*.1 <br />tJ <br />LU <br />oJ <br />W <br />O <br />> <br />Q <br />1LU <br />Ot_ <br />� <br />w <br />oc <br />o <br />o <br />Q <br />Uj <br />a <br />o <br />a <br />0 <br />sz! <br />e <br />0 <br />a0� <br />dl <br />V <br />SUHDIV. 8a LOT: <br />ABBOTT <br />PARK <br />LOT #36 <br />BLK #9 <br />PROJECT# <br />04181.000— 36091 <br />MODEL, <br />3EFB <br />"2447- ROBIE" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />60 MPH EXP. C <br />ARCHITECT - <br />STATE OF FLORIDA <br />ND A. ABOUCHACRA <br />AR NO 93723 , <br />DATE: 05/26/20 1 <br />' SCALE: 1/4„ = 1Apf 1 <br />SHEET <br />E I <br />