Laserfiche WebLink
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />" <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED ALAS SHALL BE CONSTRICTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER PBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. PM044 AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, @HALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (20n) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />$. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALL$ SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH POP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />SOLID LINE" SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OW <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />FREE DRAW AIR <br />HANDLER CLOSET <br />W/LOUVEREO DOOR <br />SUPPLIED BY <br />BUILDER <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE. 1/4 " 1'-0* <br />1441 N. RONALD REAOAN BLVD, <br />LONGWOOD, FL32750 <br />PH; 407-774-6078 <br />FAK 407-7744078 <br />www.abdasigngroup.com <br />AA N: 0003325 <br />C <br />W <br />ABBOTT <br />LOT #11 <br />BLK #10 <br />PROJIcCT#► <br />4181. 0-1 101 <br />MODs11 <br />3EFB <br />"2447—ROBIE" <br />OA tAaa 811INO: <br />RIGHT <br />PAGZ: <br />SECOND <br />FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH EXP. <br />DA�l'>c: 03/13. <br />BCA=:1/4" = 1'-0" <br />spxmw <br />M2 <br />