Laserfiche WebLink
z <br />a <br />SEE SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN REFER TO PLANS <br />FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />_ W/ 60 MIN. GRADE D PAPER BACKED <br />- LATH OVER BARRICADE PLUS WRB <br />_ (OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />�SL�:7�2X LEDGER BOARD <br />u N �Y(REFER TO ELEV.) <br />INSULATION AS I 2X ALUM WRAPPED FASCIA <br />PER SPECS. ----- BD. w/ALUM DRIP EDGE <br />PRE-ENGINEERED SOFFIT INSTALLED PER <br />GABLE END ROOF MANUF. SPECS <br />TRUSS - REFER TO 2X PT BLOCKING <br />STRUCTURALS HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. MASONRY LINTEL - REFER TO <br />- U STRUCTURALS <br />TYP. HIPPED PENT ROOF DETAIL <br />SCALE: 1/2" = 1'-O" 1-STORY- MASONRY WALL <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />t2 <br />R905.1.1.1 (SEE SHEET CS2) <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />�nnnon, <br />STRUCTURAL. <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION PER <br />2x6 ALUM WRAPPED FASCIA <br />COMMUNITY SPEC. <br />BD. w/ALUM DRIP EDGE <br />SEE ENERGY CALCS. <br />_EE <br />1/2" (MIN.) CLG. BD. SOFFIT INSTALLED PER <br />1x PT DRAPE BLKG MANUF. SPECS <br />ABOVE WINDOWS 1/2" 2X PT BLOCKING <br />G.W.B. <br />SEE STRUCTURAL <br />WINDOW PER PLAN PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING Qa 24" O.C. SLOPE GRADE AWAY <br />BASE BOARD FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL P WINDOW <br />SCALE: 1/2" = V-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />"'GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO------. <br />FINISH <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GYPSUM - <br />GYPSUM <br />BOARD <br />BOARD z <br />"' GYPSUA <br />Ir <br />w <br />GARAGE a <br />BOARD <br />NICHE FOI <br />ELECTRIC <br />PANEL & <br />WIRING <br />cV <br />M <br />-ELECTRICAL <br />PANEL <br />ELECTRIC <br />PANEL <br />N <br />EXTERIOR <br />C° <br />co <br />CMU BLO( <br />WALL <br />N CONCRET <br />CONCRETE <br />CURB REFER CURB REF <br />TO PLANS TO PLANS <br />CONCRETE <br />SLAB <br />wow000 <br />GRADEOAT <br />..� <br />GRADE <br />GARAGE <br />FLOOR <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />12 <br />R905.1.1.1 (SEE SHEET CS2) <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OL TOP OF C.M.U. <br />I I <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />j <br />EE <br />BD. WALUM DRIP EDGE <br />E V. <br />1/2" (MIN.) <br />---- <br />CLG. BD. <br />SOFFIT INSTALLED PER <br />e' TYPE'X' GYP. BD. <br />MANUF. SPECS <br />TO BE PROVIDED <br />WHEN LIVING SPACE <br />2X PT BLOCKING <br />IS ABOVE GARAGE) <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL 4 SPECS <br />PLANSSLOPE SLOPE FIN. FL. <br />23 ® <br />- —FOUNDATION <br />co c PER STRUCTURAL DRAWINGS <br />WALL SECTION P GARAGE DOOR <br />SCALE: 1/2" = 1'-O" <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER TO PLANS <br />T.O. M <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I I <br />L------ J <br />z <br />Q <br />Cc <br />w <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />cV <br />Zh <br />co <br />cV <br />i <br />%L <br />_1E <br />----- <br />ER <br />-Ill <br />ir <br />7�T <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />IIY <br />w <br />} 2 <br />�:OOF- <br />woCQO <br />p <br />Ir (nUwW <br />W <br />Q = H <br />cr cc <br />,6z0OW <br />Z <br />C J Q < <br />W (L cr <br />= z u- C/) <br />ri <br />N <br />O � <br />Q <br />H <br />0 <br />0 <br />o <br />U <br />z <br />0 <br />0-1 <br />O <br />MGM <br />® <br />u <br />mm"w <br />1 <br />Or <br />r� <br />w <br />�i <br />O <br />i~ <br />IL <br />o; <br />U) <br />w <br />U <br />O <br />w <br />F_ <br />9 <br />in <br />OwCZ <br />aaaaa <br />JAN 19 2022 <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6120 <br />RELEASED:1/20/202 <br />SHEET <br />AS•2 <br />z <br />L <br />z <br />D <br />j <br />z <br />JJ <br />D <br />z <br />z <br />Q <br />z <br />z <br />D6 <br />4 <br />z <br />I <br />i <br />