Laserfiche WebLink
A <br />0 <br />mlc.flr%AlAlC/lT <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1/4"=1'-0" SCALE: 1/8"=1'-0,�22::x34::� <br />11"x17 <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. I BREAKER <br />PVC 1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />■ <br />1 <br />1 <br />AU <br />I <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />-� CEILING MOUNTED LED LIGHT FIXTURE <br />H- WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />VAPOR PROOF LIGHT FIXTURE <br />+.0LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />4 EXHAUST FAN <br />Q EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />Q PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />►4 TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />p7 ELECTRIC METER <br />s ELECTRIC PANEL <br />__mbL_ DISCONNECT SWITCH <br />Q JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />C` <br />W <br />i=0C <br />�00� <br />Lu <br />oWCa0 <br />p <br />C) <br />cn w <br />a�>wJ <br />�jrccCc <br />�10E-z <br />�tLL00cn <br />zzzP'z <br />c Q J <br />Wa=crO- <br />� U) 0 L) <br />- Z lL U) <br />QZp <br />Z n <br />c o <br />n <br />g~� <br />0 2Y^ <br />�7 <br />Fa- <br />0 <br />0 <br />0y <br />V <br />0 <br />°° <br />a41 <br />u <br />0 <br />w <br />w <br />U <br />�. <br />w <br />w <br />z <br />0 <br />a <br />O_ <br />ix <br />U) <br />W <br />O <br />N <br />O� <br />�Z <br />aaaaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 610 Of <br />RELEASED: 11/19/21 <br />SHEET <br />EIA <br />