Laserfiche WebLink
wl <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />• OR COPPER <br />OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />T <br />II <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL <br />METER (V.I.F.) <br />A/C <br />DISCONNECT <br />h/ GFWP <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=V-0" <br />OUTLET FOR <br />U/C REF. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />F� GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />- CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />06 VAPOR PROOF LIGHT FIXTURE <br />*c LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />() EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />f4 TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />(p ELECTRIC METER <br />= ELECTRIC PANEL <br />DISCONNECT SWITCH <br />dD JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />tr <br />W <br />} 2 � <br />�OOI- <br />} <br />>oCQO <br />WC)F- <br />� 0 W 0 <br />Q = W_ ~ <br />�IL m <br />IYcr <br />Y 0 F- Z <br />LL00C/) <br />ZzZF-Z <br />w J Q J <br />W D_=C_ <br />�Wo00 <br />= Z U- W <br />cz n <br />Q � <br />a <br />(� N <br />n <br />Q o <br />O <br />� a <br />Q <br />0 <br />0 <br />O <br />ft <br />r� <br />V <br />Z <br />o <br />IL <br />t <br />o <br />� <br />LL� <br />i� <br />0 <br />U <br />a, <br />U) <br />w <br />w <br />w <br />x <br />a <br />O <br />P <br />0. <br />U) <br />W <br />z <br />Z <br />OEn- <br />o <br />wZ <br />aaaaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6120 <br />RELEASED: 1/18122 <br />SHEET <br />Elel <br />