Laserfiche WebLink
-ATTIC VENTILATION ZONE 3- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />SQ. IN. <br />SQ. FT. <br />SQ. IN. <br />100 <br />14400 <br />0.333 <br />48.000 <br />ROOF VENTS <br />SOFFIT VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />VENTS OF <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />0 <br />0 <br />0 <br />0.333 <br />48.000 <br />8 <br />ROOF TOP ATTIC VENT: <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SQ. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />ROOF PLAN <br />SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = V-0" ON 11 x17 PAPER) <br />-ATTIC VENTILATION ZONE 2- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />Q. IN. <br />SQ. FT. <br />SQ. IN. <br />1072 <br />154368 <br />3.573 <br />514.560 <br />ROOF VENTS <br />SOFFIT VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />VENTS OF <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />1.429 <br />205.824 <br />2 <br />2.144 <br />308.736 <br />50 <br />ROOF TOP ATTIC VENT: <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SQ. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />00 <br />\O O \ <br />d I� 00 00 I� <br />00 <br />t` t\ <br />rnrn <br />c d <br />o 00 00 o <br />00 00 <br />o�00 <br />SIDE ELEVATION <br />SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = 1'-O" ON 11x17 PAPER) <br />_ O M <br />I I <br />00 7� <br />I <br />00 <br />t` <br />00 <br />rn <br />I <br />M s <br />00 _I O <br />O O <br />-ATTIC VENTILATION ZONE 1- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />SQ. IN. <br />SQ. FT. <br />SQ. IN. <br />1255 <br />180720 <br />4.183 <br />602.400 <br />ROOF VENTS <br />SOFFIT VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />VENTS OF <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />1.673 <br />240.960 <br />2 <br />2.510 <br />361.440 <br />59 <br />ROOF TOP ATTIC VENT: <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SO. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />COIF M'ff SPEC (+1/2'), TYP. <br />REAR ELEVATION <br />SCALE 1/8" = 1'-O" (NOTE: SCALE 1/16" = V-0" ON 11x17 PAPER) <br />SIDE ELEVATION <br />SCALE 1 /8" = V-0" (NOTE: SCALE 1 /16" = 1'-O" ON 11 x17 PAPER) <br />O <br />124 <br />v <br />co <br />41 <br />v J <br />O <br />00 <br />V <br />A' <br />v� <br />Ur-+ <br />9 <br />M <br />c� <br />41 <br />N <br />tPulteGroup- <br />F�1 <br />� <br />� <br />0 <br />0 <br />J <br />0 <br />00 <br />-ic <br />v <br />a'o <br />N <br />� <br />� <br />� <br />O <br />U <br />W <br />W <br />.-SI4 <br />cc$ic <br />as <br />� <br />W <br />� <br />� <br />A <br />PRODUCT MANAGER <br />RELEASE <br />PROJECT TYPE I <br />Sinele Familv <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />VVMtestone <br />NPC CHILD NUMBER <br />2117.501 <br />SHEET <br />A2.02 <br />