Laserfiche WebLink
GENERAL NOTES <br />- DO NOT SCALE DRAWINGS <br />- ALL WORK MUST BE COMPLETED TO THE APPLICABLE FLORIDA BUILDING CODES <br />- ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO A PULTE REPRESENTATIVE <br />- CONTRACTORS SHALL MAINTAIN A CLEAN JOB SITE <br />- CONTRACTORS ARE RESPONSIBLE TO FOLLOW ALL APPLICABLE OSHA REGULATIONS <br />TERMITE PROTECTION <br />- TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES AND A CERTIFICATE OF COMPLIANCE <br />SHALL BE ISSUED TO THE BUILDING DEPARTMENT <br />TIM <br />PulteGr(jup — SOIL TREATMENT, BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD ARE ACCEPTABLE FORMS OF <br />TREATMENT <br />— INSPECTION FOR TERMITES <br />o PROVIDE 6" CLEARANCE FROM GRADE WITH EXTERIOR WOOD FRAMED WALLS <br />■ 4" CLEARANCE REQUIRED AT GARAGES AND PORCHES <br />EXTERIOR <br />— WATER RESISTANCE <br />o THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT <br />PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A <br />WATER—RESISTANT BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY R703.2 AND A MEANS <br />OF DRAINING TO THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. <br />■ THIS IS NOT REQUIRED OVER CMU <br />— FLASHING <br />o APPROVED CORROSION RESISTANT FLASHING SHALL BE INSTALLED IN A SHINGLE FASHION PER <br />R703.4 <br />— EXTERIOR PLASTER <br />o EXTERIOR PLASTER SHALL BE INSTALLED IN COMPLIANCE WITH ASTM C926, ASTM C1063 OR ASTM <br />C1787 AND R703.7 <br />— LATH <br />o LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION RESISTANT MATERIALS. EXPANDED METAL <br />OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 %' LONG, 11 GAGE NAILS HAVING <br />A 7/16' HEAD, OR 1-1/2" LONG, 16 GAGE STAPLES, SPACED IN ACCORDANCE WITH ASTM C1063 OR <br />C1787, OR AS OTHERWISE APPROVED. <br />o WEEP SCREEDS, A minimum 0.019—inch (0.5 mm) (No. 26 galvanized sheet gage), <br />corrosion —resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 <br />inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance <br />with ASTM C926. The weep screed shall be placed not less than 4 inches (102 mm) above the earth or 2 <br />inches (51 mm) above paved areas and shall be of a type that will allow trapped water to drain to the <br />exterior of the building. The weather —resistant barrier shall lap the attachment flange. The exterior lath <br />shall cover and terminate on the attachment flange of the weep screed. <br />— SIDING <br />o FIBER —CEMENT SIDING IS TO BE INSTALLED IN ACCORDANCE WITH ASTM C1186 AND R703.10 <br />— MASONRY <br />o BRICK IS TO BE INSTALLED PER R703.8 <br />o ADHERED MASONRY IS TO BE INSTALLED PER R703.12 <br />ROOFING <br />— UNDERLAYMENT R905.1.1 underlayment for asphalt, metal, mineral surfaced, slate and slate —type roof <br />coverings. <br />0 Underlayment for asphalt shingles, metal roof shingles, mineral surfaced roll roofing, slate <br />and slate —type shingles, and metal roof panels shall comply with one of the following <br />methods: <br />■ A self —adhering polymer —modified bitumen underlayment complying with ASTM D1970 applied <br />over the entire roof. <br />■ A minimum 4—inch wide strip of self —adhering polymer —modified bitumen complying with ASTM <br />D1970 or a minimum 3-3/4 — inch wide strip of self —adhering flexible flashing tape <br />complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment <br />complying with ASTM D226 Type II, ASTM D4869 Type III or IV, or ASTM D6757, or a synthetic <br />underlayment meeting the performance requirements specified, is required to be applied over <br />the strips/tape over the entire roof. (See Table 1507.1.1.1 of the FBCB or Table R905.1.1.1 of <br />the FBCR for fastener type and spacing). <br />■ Two layers of felt underloyment comply ASTM D226 Type II or ASTM 4869 Type III or IV, or <br />two layers of a synthetic underlayment meeting the performance requirements specified, <br />lapped and fastened as specified. <br />— FLASHING R903.2 <br />o Flashings shall be used to seal roofing systems, where the system is interrupted or terminated and <br />shall be installed in a manner that prevents moisture from entering the wall and roof through <br />joints in copings, through moisture permeable materials and at intersections with parapet walls and <br />other penetrations through the roof plane. <br />— ASPHALT SHINGLES SHALL BE INSTALLED PER R905.2 <br />— CLAY AND CONCRETE TILE SHALL BE INSTALLED PER R905.3 <br />— METAL ROOF SHINGLES SHALL BE INSTALLED PER R905.4 <br />GENERAL NOTES <br />VENTILATION / ATTIC ACCESS <br />— MIN. NET FREE VENTILATION SHALL BE 1 /150 OF THE AREA OF VENTED SPACE WHEN USING SOFFIT <br />VENTS ONLY PER R806.2 <br />— MIN. NET FREE VENTILATION SHALL BE 1/300 OF THE AREA OF VENTED SPACE WHEN USING A <br />COMBINATION OF ROOF AND SOFFIT VENTS PER R806.2 <br />o 40%-50% OF REQUIRED VENTILATION SHALL BE PROVIDED IN THE UPPER PORTION OF THE ATTIC <br />LOCATED NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. THE REMAINING <br />VENTILATION SHALL BE OBTAINED THROUGH SOFFIT VENTS <br />— PROVIDE MIN. 1" FREE SPACE BETWEEN INSULATION AND ROOF SHEATHING <br />— ATTIC ACCESS IS REQUIRED WHEN THE HEIGHT IS GREATER THAN 30' AND THE AREA IS GREATER <br />THAN 30 SF <br />o THE HEIGHT IS MEASURED FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE BOTTOM OF <br />THE ROOF FRAMING MEMBERS <br />o MIN. ATTIC ACCESS SIZE IS TO BE 22"x30' WITH 30' OF UNOBSTRUCTED HEADROOM IN THE ATTIC <br />SPACE <br />FIRE—RESISTANT CONSTRUCTION <br />— DOORS FROM GARAGE TO THE RESIDENCE SHALL BE SOLID WOOD OF NOT LESS THAN 1 3/8" IN <br />THICKNESS, SOLID OR HONEYCOMB —CORE STEEL DOOR NOT LESS THAN 1 3/8" IN THICKNESS OR <br />A 20—MIN. FIRE —RATED DOOR <br />— DUCTS IN THE GARAGE AND DUCTS PENETRATING WALLS OR CEILINGS SEPARATING THE DWELLING FROM <br />THE GARAGE SHALL BE CONSTRUCTED IN ACCORDANCE WITH R302.5.3 <br />— %" GYP. BOARD SHALL BE INSTALLED ON GARAGE SIDE OF WALLS ABUTTING THE RESIDENCE AND GARAGE <br />CEILING WITHOUT HABITABLE ROOMS ABOVE <br />— 5/8" TYPE X GYP. BOARD SHALL BE INSTALLED ON GARAGE CEILING W/ HABITABLE ROOMS ABOVE <br />— %" GYP. BOARD SHALL BE INSTALLED UNDER STAIRS FOR ENCLOSED ACCESSIBLE SPACES <br />— FIREBLOCKING SHALL BE INSTALLED PER R302.11 <br />— DRAFTSTOPPING SHALL BE INSTALLED PER R302.12 AND SHALL NOT EXCEED 1,000 SF. DRAFTSTOPPING <br />SHALL DIVIDE THE SPACE IN APPROXIMATELY EQUAL AREAS <br />WINDOWS/DOORS <br />— FIELD SHALL VERIFY ALL WINDOW/DOOR ROUGH OPENINGS <br />— PROVIDE EMERGENCY ESCAPE AND RESCUE WINDOW OR DOOR IN ALL BEDROOMS PER R310 <br />o ($) DENOTES WINDOW SHALL COMPLY WITH EMERGENCY ESCAPE AND RESCUE (EERO) REQUIREMENTS <br />o OPENINGS SHALL NOT BE LESS THAN 5.7 SF WITH A NET CLEAR OPENING OF MIN. 24" H AND <br />MIN, 20" D <br />o EERO WINDOW SILLS SHALL BE INSTALLED NO MORE THAN 44" A.F.F. <br />— ONE EGRESS DOOR SHALL BE PROVIDED PER DWELLING UNIT WITH A CONTINUOUS AND UNOBSTRUCTED <br />PATH WITHOUT GOING THROUGH A GARAGE <br />o MIN. CLEAR WIDTH 32" WHEN OPEN AT 90 DEGREES <br />o MIN. HEIGHT 78" <br />o FINISHED FLOOR SHALL BE MAX. 1 1/2" BELOW TOP OF THRESHOLD <br />o PORCH SHALL BE MAX. 7-3/4" BELOW TOP OF THRESHOLD FOR IN —SWING DOORS <br />— OPENINGS SHALL BE PROTECTED IN WIND —BORN DEBRIS AREAS IN ACCORDANCE WITH R301.2.1.2 <br />— TEMPERED GLASS SHALL BE INSTALLED WITH THE FOLLOWING <br />o FIXED AND OPERABLE PANELS IN DOORS <br />■ GLAZING WITHIN 24' OF EITHER SIDE OF DOOR IN THE PLANE OF THE DOOR IN A CLOSED <br />POSITION <br />■ GLAZING IS ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF THE DOOR IN A CLOSED <br />POSITION AND WITHIN 24" OF THE HINGE SIDE OF AN IN —SWING DOOR. <br />o WINDOWS <br />■ GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION: <br />• WHEN EXPOSED AREA IS OVER 9 SF <br />• BOTTOM EDGE OF GLAZING IS LESS THAN 18' A.F.F. <br />• THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES (914 MM) ABOVE THE FLOOR; <br />AND <br />• ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES (914 MM), MEASURED <br />HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING <br />o WINDOWS ADJACENT TO THE BOTTOM STAIR LANDING <br />■ WHEN BOTTOM EDGE OF GLAZING IS LESS THAN 36" ABOVE THE PLANE OF THE WALKING <br />SURFACE <br />■ WHEN GLAZING IS WITHIN 60' OF BOTTOM STAIR LANDING <br />o WET AREAS <br />■ GLAZING IN WALLS OR ENCLOSURES CONTAINING OR FACING HOT <br />TUBS, SPAS, BATHTUBS, SHOWERS OR SWIMMING POOLS SHALL BE TEMPERED IF SILL HEIGHT IS <br />LESS THAN 60" A.F.F., MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />■ SHOWER AND/OR TUB ENCLOSURES SHALL BE TEMPERED <br />WOOD <br />— ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE —PRESERVATIVE —TREATED WOOD <br />INSULATION <br />— INSULATION SHALL BE INSTALLED PER APPROVED LOT SPECIFIC ENERGY CALCULATIONS <br />— INSULATE, THERMO—PLY AND SEAL AREAS BEHIND TUBS OR SHOWERS ON EXTERIOR WALLS <br />— INSTALL WOOD SHEATHING OR THERMO—PLY ON ATTIC SIDE WHEN CONDITIONED SPACE ABUTS <br />UNCONDITIONED ATTIC SPACE TO CREATE A 6—SIDED INSULATION ASSEMBLY <br />DRYWALL <br />— %' SAG —RESISTANT GYPSUM CEILING BOARD SHALL BE USED ON CEILINGS WITH 24" O.C. SPANS <br />ACCESSIBILITY <br />— ONE BATHROOM LOCATED ON HABITABLE GRADE LEVELS SHALL PROVIDE A DOOR THAT HAS A 29" CLEAR <br />OPENING PER R320.1.1. A POWDER BATH CAN BE USED IF THERE ARE NO BATHS ON THE GROUND FLOOR <br />WITH A TUB OR SHOWER <br />o ALL DOORS LEADING TO THE BATHROOM INCLUDING PRIVATE WATER CLOSET DOORS SHALL MEET THIS <br />REQUIREMENT. <br />o CLEAR OPENING CAN BE ACHIEVED WITH A 2/8 SWING DOOR OPENED AT 90 DEGREES OR A 2/6 <br />POCKET DOOR <br />SITE ADDRESS <br />— BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. THE ADDRESS SHALL BE NO <br />LESS THAN 4" IN HEIGHT AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY <br />GUARDS AND WINDOW FALL PROTECTION <br />— GUARDS SHALL BE PROVIDED WHEN WALKING SURFACES ARE LOCATED MORE THAN 30" ABOVE <br />GRADE (WITHIN 24" HORIZONTALLY) OR A.F.F. <br />— GUARDS SHALL BE MIN. 36' <br />o EXCEPTION: 34" IS ALLOWED IF THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDE <br />OF THE STAIRS <br />— GUARDRAILS SHALL NOT INCLUDE OPENINGS THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE <br />— WINDOWS WHERE THE TOP OF THE SILL IS LESS THAN 24" A.F.F. AND GREATER THAN 72' ABOVE FINISHED <br />GRADE OF OTHER SURFACE SHALL HAVE A WINDOW OPENING CONTROL DEVICE INSTALLED <br />STAIRS <br />— MIN. CLEAR WIDTH 36" <br />o HANDRAILS SHALL NOT PROJECT MORE THAN 4 �" ON EITHER SIDE OF THE STAIRWAY <br />— MIN. HEADROOM 6'-8" <br />— MAX. RISE 7-3/4" <br />— MIN. TREAD DEPTH 10" <br />— HANDRAILS <br />o 34"-38" ABOVE SLOPE PLANE <br />o HANDRAILS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT ON STAIRWAYS OF MORE <br />THAN FOUR RISERS <br />0 1 %"-2" GRIP SIZE OR GRASPABLE FINGER RECESS <br />ELECTRICAL <br />— SMOKE ALARMS COMPLYING WITH NFPA 72 SHALL BE INSTALLED: <br />o IN EACH SLEEPING ROOM <br />o OUTSIDE EACH SLEEPING ROOM <br />o ON EACH ADDITIONAL STORY <br />o CANNOT BE INSTALLED WITHIN 3' HORIZONTALLY OF A BATHROOM THAT CONTAINS A BATHTUB OR <br />SHOWER <br />— SMOKE ALARMS SHALL BE HARD —WIRED W/ BATTERY BACKUP AND INTERCONNECTED IN SUCH A MANNER <br />THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS <br />CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED WITHIN 10, OF ALL BEDROOMS <br />o COMBINATION SMOKE/CARBON MONOXIDE ALARMS ARE PERMITTED <br />— THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE <br />OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR <br />VEHICLE SPACE <br />— GROUND —FAULT CIRCUIT PROTECTION; ALL 120V SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED <br />OUTDOORS, IN BATHROOMS, IN KITCHENS, GARAGES, LAUNDRY AND AT DISHWASHER SHALL HAVE GFCI <br />CIRCUIT BREAKERS OR RECEPTACLES <br />— BRANCH CIRCUITS THAT SUPPLY 120—VOLT, SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED IN <br />KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, <br />SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS <br />SHALL BE PROTECTED WITH ARC —FAULT CIRCUIT —INTERRUPTER PROTECTION PER FBCR E3902.16 AND <br />SHALL BE LISTED AS TAMPER —RESISTANT <br />— NOT LESS THAN 90 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE <br />HIGH —EFFICACY LAMPS OR NOT LESS THAN 90 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING <br />FIXTURES SHALL CONTAIN ONLY HIGH —EFFICACY LAMPS <br />O""A� <br />C. <br />A ' <br />W <br />cn <br />� <br />c <br />.o <br />A� <br />4� <br />a� <br />V'-4 <br />cd <br />0 <br />cn� <br />Ct <br />N� <br />*PulteGroup- <br />00 <br />� <br />O <br />r`' <br />00 <br />00 <br />� <br />N <br />O <br />c <br />Z <br />CIR <br />PRODUCT MANAGER <br />RELEASE <br />DATE: xx Ax /xxxx <br />PROJECT TYPE <br />el. Y 79 <br />SPECIFICATION LEVEL I <br />Pulte <br />PLAN NAME <br />Whitestone <br />NPC CHILD NUMBER <br />2117.501 <br />SHEET <br />GO.02 <br />