Laserfiche WebLink
N <br />R <br />00 <br />o � <br />O <br />1 LIFE SAFETY FLOOR PLAN <br />K�E7 114 ' = /'-0' <br />BUILDING CODE ANALYSIS <br />I. Codes in of f ect: <br />5. Exit Calculations <br />Permitted <br />Proposed <br />Florida Building Code 2007 Edition with 2009 <br />ammendments <br />NFPA 101 2006 Edition <br />Max. Travel Distance: <br />300' <br />54'-0' <br />Max. Dead End Corridor: <br />30' <br />2° Use and Occupancy Cl assi f i cati on: <br />Business <br />Min. Corridor Width: <br />44" <br />57" <br />As per FBC Chapter 3 and NFPA 101 <br />Min. Clear Opening of Exit Doors: <br />32" <br />32" <br />Exit Units <br />23" <br />224" <br />J. Type of Construction: <br />Type III-B9 Fully Sprinklered <br />6.. Interior Finish Requirements <br />As per FBC Section 602 and NFPA 10/ Table <br />80l Type 111 (2,0,0 <br />As per FBC Table 803.5 <br />4. Building Occupancy <br />and NFPA 101 Table A 10.2.2 <br />Building Occupancy per FBC Table 1004.1.2 <br />100/per sq.f t. <br />Exits: <br />Type A <br />and NFPA 101 table 7.3.1.2 (in SF/Occupant): <br />2,162 SF <br />Exit Access Corridors: <br />Type A <br />Allowed Occupancy <br />21 <br />Rooms & Enclosed Spaces: <br />Type A <br />SYMBOL LEGEND <br />® F.E. <br />FIRE EXTINGUISHER <br />F.E.C. <br />EW <br />FIRE EXTINGUISHER CABINET <br />MAGNETIC DOOR HOLDER <br />SMOKE DETECTOR <br />�H <br />HEAT DETECTOR <br />EP I <br />FIRE ALARM PULL STATION <br />S * <br />STROBE <br />HIS <br />HORN AND STROBE <br />EXIT LIGHTS <br />EXIT LIGHTS WITH DIRECTIONAL ARROW(s) <br />84° <�- <br />EXIT WIDTH IN INCHES <br />125' <br />INTERIOR EXIT PATH AND DISTANCE <br />A <br />SMOKE COMPARTMENT DESIGNATION <br />Project No. 09029.00 <br />A 1 0 1 <br />©2009 BH/PK Architects, Inc. <br />CA AI ld',. C..r ,.+.. <br />