Laserfiche WebLink
OWNER: <br />Florida Cancer Specialists <br />Contact: Susan Parker <br />38010 Medical Center Avenue <br />Zephyrhills, FL 33450 <br />Tel: (813) 783-1676 <br />Fax: (813) 783-1929 <br />ARCHITECT: <br />SaltCo, LLC <br />2650 Bahia Vista Street - Suite 302 <br />Sarasota, Florida 34239 <br />Tel: (941) 312-5523 <br />Fax: (941) 312-5529 <br /># AA-26001479 <br />MECHANICAL, ELECTRICAL , PLUMBING, & <br />SMITH, SECKMAN, & REID, INC. <br />301 North Cattlemen Road <br />Suite 300 <br />Sarasota, Florida 34232 <br />Tel: (941) 907-7750 <br />Fax: (941) 907-7751 <br />GENERAL NOTES <br />IT IS THE RESPONSIBILITY OF EACH SUBCONTRACTOR TO REVIEW ALL <br />DRAWINGS, PROJECT MANUAL, ADDENDA, ETC. TO ASSURE <br />COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO <br />REVIEW ALL CONTRACT DOCUMENTS FOR APPLICABLE ITEMS OF WORK <br />SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING ALL <br />WORK REQUIRED <br />1. EXISTING CONDITIONS - THE EXISTING CONDITIONS SHOWN ON <br />THESE DRAWINGS ARE BASED ON INFORMATION PROVIDED TO <br />THE ARCHITECT. THE CONTRACTOR SHALL VERIFY ALL <br />EXISTING CONDITIONS ON THE JOB SITE, AND NOTIFY THE <br />ARCHITECT OF DEVIATIONS FROM THESE DRAWINGS PRIOR TO <br />FABRICATION AND INSTALLATION OF THE WORK. <br />2. DRAWINGS - THESE DRAWINGS SHALL NOT BE SCALED. REFER TO <br />DIMENSIONS INDICATED, ACTUAL SIZES OF CONSTRUCTION <br />ITEMS OR OTHER METHOD OF LOCATING CONSTRUCTION. WHERE <br />NO DIMENSION OR METHOD OF DETERMINING A LOCATION IS <br />GIVEN, VERIFY CORRECT LOCATION WITH ARCHITECT PRIOR TO <br />INSTALLATION. <br />3. DIMENSIONS - DIMENSIONS ON PLANS ARE FROM COLUMN GRID <br />LINES, FACE OF MASONRY, FACE OF EXISTING WALL OR FINISHED <br />SURFACE OF FRAMED WALL, UNLESS NOTED OTHERWISE. <br />DIMENSIONS INDICATED AS CLEAR SHALL BE A MINIMUM <br />DIMENSION, FACE TO FACE OF FINISH MATERIALS. <br />4. PRECAUTIONS - IF UNFORESEEN CONDITIONS ARE DISCOVERED <br />WHICH COULD CAUSE ADVERSE EFFECTS UPON THE STRUCTURE <br />OR ITS OCCUPANTS, REPORT ANY SUCH CONDITION <br />IMMEDIATELY TO THE ARCHITECT. TAKE PRECAUTIONS TO <br />PROPERLY SUPPORT THE STRUCTURE. THE CONTRACTOR SHALL <br />REPORT ALL HAZARDOUS MATERIALS DISCOVERED TO OWNER, <br />ARCHITECT AND AUTHORITIES HAVING JURISDICTION. <br />5. PLUMBING, MECHANICAL, ELECTRICAL, FIRE PROTECT., <br />STRUCTURAL, CIVIL- BRING TO THE ATTENTION OF THE <br />ARCHITECT ALL CONFLICTS WITHIN THE WORK. <br />6. EXIT ACCESS - MAINTAIN FREE, SAFE, AND APPROVED MEANS OF <br />EGRESS IN AND OUT OF PROJECT LOCATION IN ACCORDANCE <br />WITH REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES. <br />7. NEW / EXISTING - NEW WORK SHALL ALIGN WITH AND MATCH <br />EXISTING WORK EXCEPT WHERE OTHERWISE DIMENSIONED OR <br />DETAILED <br />8. COORDINATION / ADJUSTMENT - CONTRACTOR SHALL <br />COORDINATE ALL NEW WORK WITH EXISTING CONDITIONS AND <br />ADJUST AS REQUIRED UPON ARCHITECT'S REVIEW. <br />BASIC CRITERIA <br />CONSTRUCTION: <br />OCCUPANCY: <br />AREA MAP <br />EOUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVENUETC <br />ZEPHYRHILLS, FL 33450 SITE � a <br />LOCATION <br />AREA OF WORK <br />r. . . . . . . . . . . E <br />IV W <br />F. <br />Lei <br />DRAWING SYMBOLS <br />WALL SECTION DETAIL <br />_4(X NUMBER <br />AXXX WALL SECTION DRAWING <br />NUMBER <br />X DETAIL NUMBER <br />/ 1 AXXX DRAWING NUMBER <br />I <br />A <br />COLUMN GRID REFERENCE <br />NUMBER/LETTER <br />+ <br />1 <br />PARTITION SECTION <br />X DETAIL NUMBER <br />OIL LEVEL LINE ELEVATION <br />XXX X'-X' REFERENCE POINT <br />REVISION NUMBER <br />AREA OF REVISION <br />A 707 SHEET NUMBER <br />3� DIRECTION OF VIEW <br />INTERIOR ELEVATION <br />NUMBER <br />NFPA TYPE II (0,0,0), NON-SPRINKLERED <br />F.B.C. TYPE II-B, NON-SPRINKLERED <br />NFPA 101: CH. 39: EXISTING BUSINESS <br />F.B.C.: BUSINESS - GROUP B <br />BUILDING AREA TOTAL: f 41770 SF <br />INTERIOR RENOVATED AREA TOTAL: ± 835 SF <br />TOTAL NEW AREA: f 0 SF <br />NO NEW AREA WILL BE ADDED AS A PART OF THIS PROJECT. <br />APPLICABLE CODES: <br />Florida Building Code, Building, 2014 Edition <br />NFPA 1, The Florida Fire Prevention Code, Fifth Edition, 2012 <br />NFPA 101 Life Safety Code, 2012 Edition <br />Florida Building Code, Plumbing, 2014 Edition <br />Florida Building Code, Mechanical, 2014 Edition <br />Florida Building Code, Fuel Gas, 2014 Edition <br />Florida Building Code, Existing Building, 2014 Edition <br />NFPA 70 - 2011 - National Electric Code (NEC) <br />NFPA 72 - 2010 - National Fire Alarm Code <br />NFPA 99 - 2012 - Standard for Health Care Facility <br />Florida Accessibility Code, 2014 Edition <br />Guidelines for Design and Construction of Health Care Facilities, 2010 Edition <br />SALT 0, LLC <br />COMMISSION N0. 71604 <br />DATE: JULY 1, 2016 <br />STANDARD ABBREVIATIONS <br />A <br />A <br />A.B. <br />AIR <br />ANCHOR BOLT <br />F <br />F.A. <br />F.A.C. <br />FIRE ALARM <br />FIRE APPARATUS CABINET <br />P <br />PART'N. <br />PARTITION <br />A/C <br />AIR CONDITIONING <br />F.B. <br />FACE BRICK <br />P.C. <br />PRECAST CONCRETE <br />ACCESS. <br />ACCESSORIES <br />F.D. <br />FLOOR DRAIN <br />P.C.F. <br />PER CUBIC FOOT <br />ADH <br />ADHESIVE <br />FDTN. <br />FOUNDATION <br />PERF. <br />P.L. <br />PERFORATED <br />ADJ. <br />ADJUSTABLE <br />F.E.C. <br />FIRE EXTINGUISHER CABINET <br />PLAS. <br />PROPERTY LINE <br />PLASTER <br />A.F.F. <br />ABOVE FINISHED FLOOR <br />F.F.L. <br />FINISH FLOOR LINE <br />P.L.F. <br />PER LINEAR FOOT <br />AHU <br />AIR HANDLING UNIT <br />F.H.C. <br />FIRE HOSE CABINET <br />PLT. <br />PLATE <br />ALT. <br />ALTERNATE <br />FIN. <br />FINISH <br />PLYWD. <br />PLYWOOD <br />ALUM. <br />ALUMINUM <br />FLASH. <br />FLASHING <br />P&M <br />PATCH & MATCH <br />ANOD. <br />ANODIZED <br />FLUOR. <br />FLUORESCENT <br />PREP. <br />PREPARATION <br />APPROX. <br />APPROXIMATE <br />FLR. <br />FLOOR <br />PT. <br />POINT <br />ARCH. <br />ARCHITECT OR ARCHITECTURAL <br />FLRG. <br />FLOORING <br />P.T. <br />PRESSURE TREATED <br />ASB <br />ASBESTOS <br />F.R. <br />FLOOR RECEPTOR <br />PTD. <br />PAINTED <br />ASPH. <br />ASPHALT <br />FT. <br />FOOT OR FEET <br />PVMT <br />PAVEMENT <br />AUTO <br />AUTOMATIC <br />FTG. <br />FOOTING <br />PUB. <br />PUBLIC <br />B <br />BD. <br />BOARD <br />FURR. <br />FURRING <br />BET. <br />BETWEEN <br />FUT. <br />FUTURE <br />Q <br />Q.T. <br />QUARRY TILE <br />BITUM. <br />BITUMINOUS <br />G <br />G. <br />GAS <br />Q.T.B. <br />QUARRY TILE BASE <br />BLDG. <br />BUILDING <br />GA. <br />GAUGE (GAGE) <br />QTY• <br />QUANTITY <br />BILK. <br />BLOCK <br />G.C. <br />GENERAL CONTRACTOR <br />R <br />R. <br />RISERS <br />BLKG. <br />BLOCKING <br />G. 1. <br />GALVANIZED IRON <br />R.A. <br />RETURN AIR <br />B.M. <br />BENCHMARK <br />GL. <br />GLASS <br />RAID. <br />RADIUS <br />BM. <br />BEAM <br />GR. <br />GRADE <br />R.D. <br />ROOF DRAIN <br />BOT. <br />BOTTOM <br />G.W.B. <br />GYPSUM WALL BOARD <br />BRG. <br />BEARING <br />RECEP. <br />RECEPTOR <br />BSMT. <br />BASEMENT <br />REF. <br />REFERENCE <br />B.W. <br />BOTH WAYS <br />REFR. <br />REFRIGERATOR <br />BNCH. <br />BENCH <br />H <br />H.B. <br />HOSE BIB <br />REINF. <br />REINFORCING <br />H.BD. <br />HARDBOARD <br />REL. <br />RELOCATED <br />C <br />C.A. <br />COMPRESSED AIR <br />H.C. <br />HOLLOW CORE <br />REQ'D. <br />REQUIRED <br />CAB <br />CABINET <br />H/C <br />HANDICAPPED <br />RESIL. <br />RESILIENT <br />CEM. <br />CEMENT <br />HDW. <br />HARDWARE <br />RET. <br />RETURN <br />C.F.I. <br />CONTRACTOR FURNISHED AND INSTALLED <br />HDWD. <br />HARDWOOD <br />REV. <br />REVISE <br />C.F.T. <br />CERAMIC FLOOR TILE <br />HGT. <br />HEIGHT <br />RFG. <br />ROOFING <br />C.G. <br />CORNER GUARD <br />H.M. <br />HOLLOW METAL <br />RGTR. <br />REGISTER <br />CHKD. PL. <br />CHECKERED PLATE <br />HORIZ. <br />HORIZONTAL <br />R.H. <br />RIGHT HAND <br />C.I. <br />CAST IRON <br />HR. <br />HOUR <br />R.L. <br />RAIN LEADER <br />C.I.P. <br />CAST IN PLACE <br />H.R. <br />HANDRAIL <br />RM. <br />ROOM <br />C.J. <br />CONSTRUCTION JOINT <br />H.W. <br />HOT WATER <br />R.O. <br />ROUGH OPENING <br />C.L.L. <br />CONTRACT LIMIT LINES <br />HVAC <br />HEAT/VENTILATING/AIR CONDITIONING <br />R.O.W. <br />RIGHT OF WAY <br />CLG. <br />CEILING <br />I <br />ICIN. <br />INCINERATOR <br />RUB. <br />RUBBER <br />CLO <br />CLOSET <br />I.D. <br />INSIDE DIAMETER <br />CLR. <br />CLEAR <br />INS <br />INSTRUMENT <br />S <br />S. <br />SINK <br />C.M. <br />CONSTRUCTION MANAGER <br />IN L. <br />INSULATION <br />S.C. <br />SOLID CORE <br />C.M.U. <br />CONCRETE MASONRY UNIT <br />INT. <br />INTERIOR <br />CNT.J. <br />CONTROL JOINT <br />.0 <br />I. <br />INVERT <br />S.D. <br />STORM DRAIN <br />CASED OPENING <br />I.P.S.C.O. <br />P. <br />IRON PIPE SIZE <br />SECT. <br />SECTION <br />COL. <br />COLUMN <br />SH. <br />SHELF <br />CONC. <br />CONCRETE <br />J <br />J.C. <br />JANITORS CLOSET <br />SHLVG. <br />SHELVING <br />CONN. <br />CONNECTION <br />JST. <br />JOIST <br />SHTG. <br />SHEATHING <br />CONST. <br />CONSTRUCTION <br />JT. <br />JOINT <br />SHT. <br />SHEET <br />CONT. <br />CONTINUOUS <br />K <br />SHWR. <br />SHOWER <br />CRS. <br />COURSES (BRICK OR BLOCK) <br />K. 0. <br />KNOCK -OUT <br />SIM. <br />SIMILAR <br />CSWK. <br />CASEWORK <br />K.O.P. <br />KNOCK -OUT PANEL <br />SPECS. <br />SPECIFICATIONS <br />C.T. <br />CERAMIC TILE <br />SPKR. <br />SPEAKER <br />C.T.B. <br />CERAMIC TILE BASE <br />L <br />LAB. <br />LABORATORY <br />SQ. <br />SQUARE <br />C.W. <br />COLD WATER <br />LAM <br />LAMINATE <br />S.ST. <br />STAINLESS STEEL <br />C.W.G. <br />CLEAR WIRE GLASS <br />LAV. <br />LAVATORY <br />STA. <br />STATION <br />L.C. <br />LAUNDRY CHUTE <br />STD. <br />STANDARD <br />D <br />D.A. <br />DOUBLE ACTING <br />L.H. <br />LEFT HAND <br />ST'L. <br />STEEL <br />D.BD. <br />DRAIN BOARD <br />LKRS. <br />LOCKERS <br />STOR. <br />STORAGE <br />DBL. <br />DOUBLE <br />L.L. <br />LIVE LOAD <br />STRUCT. <br />STRUCTURAL <br />DEPT. <br />DEPARTMENT <br />L. PT. <br />LOW POINT <br />SYS. <br />SYSTEM <br />DET. <br />DETAIL <br />DEM. <br />DEMOLITION <br />LVR. <br />LOUVER <br />T <br />D.F. <br />DRINKING FOUNTAIN <br />L.V.W. <br />LEAD VIEW WINDOW <br />T. <br />TREAD <br />DIA. <br />DIAMETER <br />M <br />TECH. <br />TECHNICIANS <br />DIAG. <br />DIAGONAL <br />M. <br />METER <br />TEL. <br />TELEPHONE <br />DIM. <br />DIMENSION <br />MAT'L. <br />MATERIAL <br />THK. <br />THICK <br />DN. <br />DOWN <br />MAX. <br />MAXIMUM <br />T&G <br />TONGUE & GROOVE <br />D.O. <br />DOOR OPENING <br />M <br />MECH. <br />MECHANICAL <br />TK.BD. <br />TACK BOARD <br />D.S. <br />DOWN SPOUT <br />MED. <br />MEDIUM <br />TOIL. <br />TOILET <br />DWG. <br />DRAWING <br />MFG. <br />MANUFACTURER <br />T.O.S. <br />TOP OF SLAB <br />D.WT. <br />DUMB WAITER <br />M.H. <br />MANHOLE <br />T.O.W. <br />TOP OF WALL <br />MIN. <br />MINIMUM <br />T.P. <br />TOILET PARTITION <br />E <br />E. <br />EAST <br />MISC. <br />MISCELLANEOUS <br />TYP. <br />TYPICAL <br />EA. <br />EACH <br />MLDG. <br />MOULDING <br />E.H.B. <br />ELECTRIC HOLD BACK <br />M.M. <br />MILLIMETER <br />U <br />UNF. <br />UNFINISHED <br />EF <br />EXHAUST FAN <br />M.O. <br />MASONRY OPENING <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />ELEC. <br />ELECTRICAL <br />M.T. <br />METAL THRESHOLD <br />URIN. <br />URINAL <br />ELEV. <br />ELEVATION <br />MTD. <br />MOUNTED <br />UTIL. <br />UTILITY <br />EMERG. <br />EMERGENCY <br />MTL. <br />METAL <br />V <br />E.P. <br />ELECTRICAL PANEL BOARD <br />MULL. <br />MULLION <br />V. <br />VACUUM <br />EQ. <br />EQUAL <br />MWK. <br />MILLWORK <br />VERT. <br />VERTICAL <br />EQUIP. <br />EQUIPMENT <br />VEST. <br />VESTIBULE <br />EXIST. <br />EXISTING <br />N <br />N. <br />N.A. <br />NITROGEN OR NORTH <br />NOT APPLICABLE <br />V.I.F. <br />VERIFY IN FIELD <br />EXH. <br />EXHAUST <br />NAT. <br />NATURAL <br />EXP'D. <br />EXPOSED <br />NOM. <br />NOMINAL <br />W <br />W. <br />WEST <br />EXP.JT. <br />EXPANSION JOINT <br />N.T.S. <br />NOT TO SCALE <br />W/ <br />WITH <br />EXT. <br />EXTERIOR <br />O <br />WD. <br />WOOD <br />E.T.R. <br />EXISTING TO REMAIN <br />0. <br />OXYGEN <br />W.G. <br />WIRE GLASS <br />O.A. <br />OVERALL <br />ON CENTER <br />W.H.O.C. <br />WALL HUNG <br />O.D. <br />OUTSIDE DIAMETER <br />W. 1. <br />WROUGHT IRON <br />O.F.I. <br />OWNER FURNISH & INSTALL <br />W.M. <br />WIRE MESH <br />O.F.C.I. <br />OWNER FURNISH, CONTRACTOR INSTALL <br />W. P. <br />WATERPROOFING <br />O.F.V.I. <br />OWNER FURNISH, VENDOR INSTALL <br />W.S. <br />WEATHER STRIP <br />O.H. <br />OVERHEAD <br />W.W.F. <br />WELDED WIRE FABRIC <br />OPG. <br />OPENING <br />®� / <br />SITE NORTH <br />LOCATION <br />DRAWING INDEXJ. <br />GENERAL <br />G001 COVER, NOTES, CODE SUMMARY, DRAWING INDEX & LOCATION MAP <br />G101 LIFE SAFETY PLAN <br />ARCHITECTURAL <br />A001 GENERAL DEMOLITION NOTES, PARTITION TYPES, DETAILS, AND FINISH SCHEDULE <br />A151 DEMOLITION PLANS, NOTES, AND DETAILS <br />A201 PLANS, DOOR AND WINDOW ELEVATIONS, DOOR SCHEDULE, AND NOTES <br />A201E PLANS, EQUIPMENT SCHEDULE, AND NOTES <br />A600 FIRE RATED CONSTRUCTION DETAILS <br />A800 INTERIOR ELEVATIONS AND CASEWORK DETAILS <br />MECHANICAL <br />M001 MECHANICAL NOTES, SCHEDULES, AND SHEET INDEX <br />M002 MECHANICAL SPECIFICATIONS <br />M003 MECHANICAL SPECIFICATIONS <br />M300 MECHANICAL PARTIAL FLOOR PLAN - DEMOLITION AND NEW CONSTRUCTION <br />M501 MECHANICAL DETAILS <br />PLUMBING <br />P001 PLUMBING NOTES AND SHEET INDEX <br />P200 PLUMBING PARTIAL FLOOR PLAN - DEMOLITION AND NEW CONSTRUCTION <br />ELECTRICAL <br />E001 ELECTRICAL LEGEND, NOTES, SHEET INDEX <br />E002 ELECTRICAL SPECIFICATIONS REVIEW DATE <br />E003 ELECTRICAL SPECIFICATIONS CITY OF ZEPHYRHI LS <br />E201 ELECTRICAL PARTIAL FLOOR PLAN - DEMOLITION PLAN EXAMINE <br />E301 ELECTRICAL PARTIAL FLOOR PLAN - NEW CONSTRUCTION <br />E402 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES <br />E501 ELECTRICAL DETAILS <br />'ILL WORK SHALL COMPLY WITH <br />'REVAILING CODES <br />=LORIDA BUILDING CODE, <br />EQUIPMENT VENDOR DOCUMENTS - GQf6WthCaEeTRIC CODE, AND <br />THE ATTACHED GE HEALTHCARE DOCUMENT P4CKAGE IS YRHILLS ORDINAN( <br />PROVIDED FOR CONTRACTOR REFERENCE. CONTACT <br />MANUFACTURER FOR ALL EQUIPMENT DESIGN, FUNCTION, AND <br />OPERATION QUESTIONS OR CONCERNS <br />C1 COVER SHEET, SITE READINESS, NOTES, AND DRAWING INDEX <br />Al EQUIPMENT LAYOUT REVIEW DATE <br />sl STRUCTURAL LAYOUT CITY OF ZEPHYRHILLS <br />S2 STRUCTURAL DETAILS PLAN EXAMINER <br />E1 ELECTRICAL LAYOUT _ <br />E2 ELECTRICAL SPECIFICATIONS <br />E3 ELECTRICAL DETAILS <br />D1 EQUIPMENT DETAILS <br />D2 EQUIPMENT DETAILS <br />SCOPE OF WORK <br />SCOPE OF WORK CONSISTS OF THE FOLLOWING: <br />INTERIOR RENOVATION TO AN EXISTING BUILDING - WORK WILL <br />INCLUDE REMOVAL OF EXISTING PARTITIONS, DOORS, <br />EQUIPMENT, AND CEILING. NEW WORK CONSISTS OF NEW <br />INTERIOR PARTITIONS, INSTALLATION OF NEW DOORS/FRAMES/ <br />SIDELITES, NEW CASEWORK AND ASSOCIATED PLUMBING <br />FIXTURES, NEW CEILING AND ASSOCIATED ELECTRICAL AND <br />MECHANICAL FIXTURES, AS WELL AS NEW INTERIOR FINISHES. <br />NO NEW AREA IS BEING ADDED AS A PART OF THIS PROJECT. <br />SaltCo, LLC <br />AA 26001479 <br />General Notes: <br />DO NOT SCALE DRAWINGS. <br />VENDOR PROVIDED EQUIPMENT SHOWN FOR REFERENCE ONLY — <br />REFER TO OWNER PROVIDED VENDOR DOCUMENTS FOR <br />ADDITIONAL INFORMATION. CONTACT EQUIPMENT MANUFACTURER <br />FOR EQUIPMENT RELATED QUESTIONS OR CONCERNS. <br />CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE <br />DRAWINGS AND SPECIFICATIONS AND NOTIFY THE ARCHITECT OF ANY <br />ERRORS OR INCONSISTENCIES PRIOR TO BEGINNING WORK. <br />CONTRACTOR SHALL VERIFY AND COORDINATE CLEAR DIMENSIONS <br />REQUIRED FOR OWNER/VENDOR FURNISHED EQUIPMENT AND <br />NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS AND <br />PROCEED ONLY UPON RESOLUTION. <br />COLOR, STYLE, PATTERN AND MANUFACTURER OF INTERIOR <br />FINISHES MAY VARY. SELECTIONS BY OWNER. VERIFY PRIOR TO <br />INSTALLATION. <br />MAINTAIN COMPLIANCE WITH OWNER —FURNISHED RADIATION SHIELDING <br />REQUIREMENTS — IN ANY RENOVATED, AND NEW CONSTRUCTION. <br />EXISTING EQUIPMENT REFERENCED AND/OR NOT SHOWN, IS REMOVED <br />BY OTHERS — UNDER SEPARATE AGREEMENT WITH OWNER. <br />REPAIR ANY PENETRATIONS/HOLES ON EXISTING FIRE OR SMOKE RATED, <br />AND LEAD —LINED WALLS WITHIN THE SCOPE OF THE WORK, IN ORDER <br />TO MAINTAIN THE INTEGRITY OF ALL REQUIRED FIRE / SMOKE RATINGS <br />— INSTALL FIRESAFING AS REQUIRED FOR COMPLIANCE (SEE SHEET <br />A600 FOR FURTHER CLARIFICATION), AND LEAD LINING <br />REQUIREMENTS. <br />MAKE NECESSARY ADJUSTMENTS TO GWB PARTITIONS, IN ORDER TO <br />ACCOMMODATE NEW RECESSED CABLE DUCTS/CONDUITS. PATCH AND <br />MATCH REMAINING ADJACENT SURFACES — RADIATION SHIELDING SHALL <br />COMPLY WITH SHIELDING PLAN. SEE DETAIL C2/A201 E FOR FURTHER <br />INFORMATION. <br />WALLS SHOWN IN ALIGNMENT ARE TO ALIGN WITH FINISHED SURFACE. <br />PROVIDE AND INSTALL FLORIDA BUILDING CODE APPROVED <br />SUBTERRAINIAN TERMITICIDE AT ALL COMPACTED SOIL TO BE COVERED <br />WITH CONCRETE FLOOR SLAB. RETREAT ALL AREAS DISTURBED BY PIPE <br />AND CONDUIT INSTALLATION, OR OTHER CONSTRUCTION WORK, PRIOR TO <br />NEW SLAB INSTALLATION. CONTRACTOR TO VERIFY TERMITICIDE <br />INSTALLATION IS IN COMPLIANCE WITH FLORIDA BUILDING CODE SECTION <br />1816, AND THAT WORK IS PERFORMED BY CERTIFIED PERSONNEL ONLY. <br />ANCER_ <br />(S P E C I ,A L I S T <br />Research Institute <br />Key Plan <br />MARK ISSUE DATE DESCRIPTION <br />Issue Log <br />JOHN P. SALT AR 92309 <br />FLORIDA CANCER SPECIALISTS <br />EQUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVE. <br />ZEPHYRHILLS, FL 33540 <br />Drawing Title <br />COVER, NOTES, CODE SUMMARY, <br />DRAWING INDEX, AND <br />LOCATION MAP <br />Commission No. <br />71604 <br />Date Issued <br />07/01/16 <br />Scale <br />AS NOTED <br />Sheet Number <br />GOT <br />Drawn By C2 <br />Approved By JPS <br />— <br />Filename 71506 0001 <br />Sa1tCo, LLC 2012 <br />