My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38010 Medical Center Ave (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38010 Medical Center Ave (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:30:32 AM
Creation date
2/28/2025 8:09:37 AM
Metadata
Fields
Template:
Building Plans
Street #
38010
Location
Medical Center Ave
Contractor
Contract Levelie Construction
Building Plans - Permit #
17644
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PHASES <br />PHASES 480V <br />208Y/120V <br />A-B-C <br />FLEXIBLE <br />METAL <br />A' A-B-C 30,3W <br />30,4W <br />FLEXIBLE <br />CONDUIT <br />METAL <br />XO <br />CONDUIT <br />GROUNDING <br />i <br />GROUNDING <br />DEVICE, LOCK <br />DEVICE, LOCK <br />NUT OR <br />GROUNDING <br />BONDING <br />NEUTRAL <br />(GROUNDED <br />NUT OR <br />GROUNDING <br />BUSHING <br />JUMPER <br />CONDUCTOR) <br />BUSHING <br />CONTINUOUS <br />1 <br />CONTINUOUS <br />GREEN <br />GROUNDING ELECTRODE <br />TRANSFORMER <br />GREEN <br />EQUIPMENT <br />CONDUCTOR (REFER <br />ENCLOSURE <br />BONDING <br />GROUND <br />TO ONE -LINE DIAGRAM <br />GROUNDING LUG <br />,JUMPER <br />FOR SIZE) <br />GROUNDING ELECTRODE <br />TRANSFORMER GROUNDING DETAIL <br />04E205 <br />I xx <br />H.V.L.V SWITCH <br />6"0 x6' PROTECTION <br />& TERMINAL <br />POSTS FILLED WITH <br />/ COMPARTMENT <br />CONCRETE(TYP. <br />- NEUTRAL CABLE <br />FOR 4) PROVIDED <br />TO GND. <br />AS INDICATED ON <br />TRANSFORMER PAD <br />PLANS <br />H V. <br />SECTION <br />PRIMARY <br />/- <br />I ' <br />CONDUITS <br />( ALLAROUND) <br />G - - <br />- <br />- H.V. CABLE <br />- - <br />-� <br />CONN. TO <br />- - <br />- <br />H.V. SWITCH <br />SHIELD WIRES TO <br />GROUND <br />° <br />XFMR i <br />A <br />SECTION A <br />[#2/0] BARE COPPER GND <br />O <br />CABLE TO COMPARTMENT <br />GND LUG. <br />L_ <br />U L.V. <br />SECTION <br />- SECONDARY CONDUITS. SEE <br />PLANS FOR DIRECTION OF RUNS. <br />PLAN <br />VIEW <br />NEW NEW <br />PDU I I UPS <br />NEW #IAWG, IN 3/4" C. I NEW #2AWG, IN 3/4" C. <br />SEE NOTE #2 SEE NOTE #2 <br />0 0 00 NEW BUSBAR <br />SEE NOTE #1 <br />®®ease ®eeeee eeeeee <br />N a6a69e 7t�,wNEW <br />#6AWG - <br />STRANDED EW #2/0 AWG <br />TERMINAL NEW BOND <br />w BOX "MG" <br />�g <br />OW <br />o EXISTING <br />z GROUND <br />> TERMINAL - CY ELECTRODES <br />a O BOX "MP" <br />J z <br />S � <br />a z NEW #2/0 AWG <br />F- TERMINAL <br />cl� cD BOX "MA" _-_I P EXISTING <br />Uj <br />t-IGHTNING <br />w 0 NEW BOND SYSTEM <br />—EXISTING LIGHTNING GROUND ROD <br />NOTE: <br />1. PROVIDE NEW GROUND BUSBAR. INSTALL IN GE EQUIPMENT ROOM. <br />REFER TO VENDOR DRAWINGS FOR EXACT LOCATION. ROUTE ALL GROUND <br />WIRES TO BUSBAR. USE HEAVY DUTY LISTED GROUNDING CONNECTORS. <br />2. PROVIDE A CONTINUOUS COPPER GROUNDING ELECTRODE CONDUCTOR <br />TO THE GROUNDING SYSTEM. CONNECT TO GROUND BUSBAR AS REQUIRED. <br />USE LISTED GROUNDING CONNECTORS. <br />GROUND BUSBAR DETAIL <br />FLOOR SLAB <br />CONDUIT TERMINATION ABOVE IN. CONDUIT TERMINATION <br />WITH BUSHING WITH BUSHING <br />� 6" M <br />e <br />u II 12" MIN. II II <br />TYPICAL / <br />C6x12GA CONT. OVER FOUR - <br />STUDS (COPE REQUIRED) FIELD <br />WELD TO VERTICAL STUDS <br />AS SHOWN <br />112" CRCxl6GAx4"-4" --_ <br />TYPICAL EACH <br />FLANGE <br />%11 <br />2-#8-18 EACH FACE <br />"D" <br />DEEP LEG TRACK <br />l2" <br />112" CRCxl6GAx4"-4" <br />„B" "B" <br />„C„ <br />MAX. <br />UNIT <br />PANEL <br />„A" <br />"B" <br />"C„ <br />"D" <br />"E" <br />"W" <br />WEIGHT <br />TYPE <br />[3 5,8"x16 <br />4- 5/16 " DIA. MACHINE <br />16" <br />120# <br />#1 <br />GA. AT 16" <br />20" <br />52" <br />SCREWS <br />O.N. <br />53„ 4 <br />300# <br />#2 <br />[3 s8"x16 <br />26 <br />42 <br />4- 5/16 " DIA. MACHINE <br />22" <br />GA. AT 16" <br />612,1 <br />SCREWS <br />O.N. <br />600# <br />#3 <br />[3 %"x16 <br />GA. AT 16" <br />32" <br />40„ <br />4- 5/16 " DIA. MACHINE <br />28" <br />O.N. <br />814„ <br />SCREWS <br />1200# <br />#4 <br />[3 5$"x16 <br />44" <br />28" <br />4- 5/16 " DIA. MACHINE <br />38" <br />GA. AT 16" <br />9 , <br />SCREWS <br />O.N. <br />z <br />NOTE: DO NOT PENETRATE 112" CRC WITH SCREWS. <br />"W" <br />FRONT VIEW <br />„E„ <br />38" DIAMETER BOLT HOLES SECURE TO <br />HORIZONTAL C6x12GA WITH 3$" DIAMETER <br />MACHINE SCREWS <br />—4 <br />177xl 7/16 "PENETRATION AT 8" ON CENTER. TYPICAL <br />SIDE VIEW FOR TOP AND BOTTOM POWER DRIVEN FASTENER <br />AT PANEL ONLY. <br />ELECTRICAL PANEL ANCHORAGE DETAIL <br />1 1/4" CONDUIT CONCEA' �^ <br />IN WALL & TERMMINATE <br />CABLE TRAY (DATA SYSTI <br />"^" `' nNDUIT CONCEALED <br />L & TERMINATED <br />LE TRAY (TELEPHONE) <br />STRUCTURE ABOVE <br />MINIMUM THREE TWISTS <br />#12 GAUGE GALVANIZED <br />WIRE HANGER (TYPICAL) <br />10E001 16325 <br />ATTACH CADDY ANGLE <br />BRACKETS (TYPICAL) <br />ATTACH CADDY ANGLE <br />BRACKET WITH #IS <br />SELF -TAPPING SHEET - <br />METAL SCREWS <br />MINIMUM 150 OFF VERTICAL <br />BOTH DIRECTIONS <br />v SYSTEMS u v <br />SYSTEMS CONDUIT <br />CONDUIT 0 4 <br />SUSPENDED �- <br />SYSTEMS CABLE TRAY SYSTEMS <br />OUTLET TYPICAL LIGHTING <br />OUTLET <br />Z WALL MOUNTED - ► FIXTURE - -- <br />CABLE TRAY N w <br />Ln <br />gZ FIXTURE SUPPRORT NOTES: <br />CORRIDOR FLOOR SLAB a 4-11/16" SQ. x 2-1/2" DIA. <br />WALLS cr z BACK BOX WITH DOUBLE 1. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST <br />So GANG PLASTER RING A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. <br />LL 2: 2. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING LESS THAN 56 <br />w 1Y POUNDS SHALL BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY <br />LU COVERPLATE DUTY GRID SYSTEM AND THEY MUST HAVE A MINIMUM OF TWO #12 GAUGE <br />SLACK SAFETY WIRES ATTACHED AT DIAGONAL CORNERS AND ANCHORED TO <br />THE STRUCTURE ABOVE. <br />FLOOR 3. ALL FIXTURES SUPPORTED ON INTERMEDIATE DUTY GRID SYSTEMS MUST <br />- — - BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR TAUT #12 GAUGE <br />WIRES ATTACHED TO THE STRUCTURE ABOVE. <br />4. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING MORE THAN 56 <br />REFER ALSO TO COVERPLATE POUNDS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR <br />& JACK DETAIL ON THIS SHEET. #12 GAUGE TAUT WIRES ATTACHED TO THE STRUCTURE ABOVE REGARDLESS <br />OF THE TYPE OF CEILING GRID SYSTEM USED. <br />5. THE FOUR TAUT #12 GAUGE WIRES INCLUDING THEIR ATTACHMENT TO THE <br />*RADIOLOGY INFORMATION SYSTEM -SIMILAR STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING FOUR TIMES THE <br />WEIGHT OF THE UNIT. <br />SYSTEMS CONDUIT TERMINATION AT TELEPHONE/DATA SYSTEMS FIXTURE SUPPORT DETAIL <br />ABLE TRAY DETAIL OUTLET DETAIL <br />UENERAL NOTE TRANSFORMER INSTALLATION DETAIL <br />i. SLOPE THE GRADE AWAY FROM THE BUILDING. <br />TRANSFORMER GND'S <br />PROTECTION POST <br />CONNECTION <br />CONTRACTOR TO VERIFY <br />H.V. & L.V. LOCATION <br />CABLE <br />SECTION <br />XFMR <br />4' 0. <br />SECTION <br />12- <br />TRANSFORMER PAD <br />CONDUIT <br />- 3^ -, <br />STUB UP <br />7-6-GRADE <br />18" <br />ROUND <br />MIN.24" <br />a <br />'- <br />GND ROD <br />- PEA SIZE GRAVEL. <br />NONMETALLIC <br />CONDUITS <br />LONG RADIUS SWEEP -SECONDARY <br />CONDUITS <br />PRIMARY CONCRETE <br />AS NOTED <br />ENCASED CONDUITS <br />ON PLANS. <br />SECTION "A -A" <br />TYPICAL FACILITY OWNED TRANSFORMER INSTALLATION DETAIL <br />412,1 <br />414" <br />38" LETTERS <br />1 n <br />PANEL PMRI <br />.� 480/277V 3PH 4W Q <br />FED FROM NDP1 <br />FOR PANELBOARDS 532" DIAMETER <br />14" LETTERS <br />NOTES: <br />1. <br />NAMEPLATE TO BE 116" PHENOLIC PLASTIC LAMINATE WITH COLORS AS FOLLOWS: <br />COLOR TYPE: <br />1. FACE TO BE BLACK, ENGRAVED LETTERS TO BE WHITE FOR NORMAL SYSTEM. <br />2. SECURE NAMEPLATE TO SURFACES WITH (2) FLAT HEAD BRASS SCREWS. <br />04E204 <br />1XX1 PANEL IDENTIFICATION (TYPE 1) <br />i REFER TO PANEL <br />SCHEDULE FOR <br />CIRCUIT BREAKER <br />AND WIRE SIZE. <br />NOTE: <br />SPD SHALL BE CLOSE-NIPPLED TO PANEL ENCLOSURE AND <br />CONNECTED TO CLOSEST CIRCUIT BREAKER IN SPACE TO <br />MINIMIZE LENGTH OF CONDUCTORS (NOT TO EXCEED 18") AND <br />AVOID UNNECESSARY BENDS. <br />04E103 INCH CIRCUIT PANEL SPD <br />AA 26001479 <br />Sheet Notes: <br />Smith <br />Seckman <br />_k%.-kReid, Inc. <br />301 North Cattlemen Road, Suite 300 <br />Sarasota, FL 34232 <br />(941) 907-7750 <br />FAX: (941) 907-7751 <br />www.ssr-inc.com <br />Firm Certification - CA-0000857 <br />S SR# 1636044.0 <br />Erick Phelps - PE 464598 <br />Christopher E. Durham - PE 476655 <br />� � •NSF•• G�Y,i <br />No.. 7�5 • <br />= D /3 lG ' If_ <br />O °•, STATE OF <br />�i���s°• FLORIOP.•°•G�� <br />///,,`S 0NA ;;��``�. <br />Christopher Edward Durham <br />PE License No. 76655 <br />`R. I <br />f [ <br />L 1, <br />T <br />Resc}t c% institute <br />Key Plan <br />CONSTRUCTION <br />DOCUMENTS <br />FLORIDA CANCER SPECIALISTS <br />EQUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVE. <br />ZEPHYRHILLS, FL 33540 <br />Drawing Title <br />ELECTRICAL <br />DETAILS <br />rA18rr <br />06/gq/go16 <br />Scale <br />Sheet Number <br />E501 <br />Drawn By KDS <br />Approved By MLG <br />Filename <br />S'aLtCo, LLC 2007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.