Laserfiche WebLink
I IF!lll' !'i <br />- '19FI <br />SPLIT <br />SYSTEM <br />A/C UNIT SCHEDULE <br />OCOOLING CAPACITY BASED ON 95° O.A.T. & 80°/67° INDOOR O <br />TEMP. <br />HEAT PUMP CAPACITY @ 47° O.A.T. <br />AO WALL MOUNTED T'STAT W/SUBBASE O SINGLE POINT POWER <br />O CONNECTION <br />g OPERATION TO 0° F <br />(DENT. <br />MANUFACTURER <br />MODEL NO. <br />INDOOR UNIT <br />INDOOR UNIT ELECT <br />COND. UNIT ELECT <br />ACCESSORIES <br />REMARKS <br />AHU <br />COND. UNIT <br />CFM <br />MIN. <br />O.A. <br />COOLING <br />O CAPACITY <br />HEATING <br />CAPACITY CAPACITY <br />ELEC COIL <br />CAPACITY <br />VOLTAGE <br />MCA/MOP <br />VOLT <br />MCA/MOP <br />AHU-1, CU-1 <br />TRANE <br />TWE090 <br />TWA073 <br />2400 <br />75 <br />78,000 <br />66,000 <br />7.5KW <br />208/60/3 <br />32.5/40 <br />208/60/3 <br />31/40 <br />OA OB CO <br />AIR MOVING EQUIPMENT OPERATION <br />DURING CONSTRUCTION <br />THE USE OF NEW OR EXISTING AIR HANDLING UNITS, FANS, OR OTHER PERMANENT AIR MOVING EQUIPMENT DURING <br />CONSTRUCTION IS PROHIBITED UNLESS APPROVED BY THE OWNER. IF APPROVED FOR USE DURING CONSTRUCTION, <br />THE FOLLOWING PROCEDURES SHALL BE FOLLOWED: <br />1. THE CONTRACTOR SHALL PROTECT THE INTERIOR OF ALL DUCTWORK, AIR HANDLING UNITS, AND OTHER EQUIPMENT <br />FROM THE ACCUMULATION OF DIRT AND DUST AND OTHER CONTAMINANTS. IF THE PERMANENT EQUIPMENT CANNOT <br />BE ADEQUATELY PROTECTED, TEMPORARY AIR MOVING/ CONDITIONING EQUIPMENT AND DISTRIBUTION SYSTEMS <br />SHALL BE UTILIZED AS REQUIRED FOR FINISHING TRADES. <br />2. PROVIDE TEMPORARY FILTERS ON ALL RETURN AND EXHAUST AIR GRILLES, OPEN DUCTWORK, AND TRANSFER <br />OPENINGS IN THE WORK AREA. <br />3. THE CONTRACTOR SHALL REMOVE ALL FILTERS USED DURING CONSTRUCTION AND REPLACE THEM WITH NEW <br />FILTERS PRIOR TO TEST AND BALANCE WORK AND PRIOR TO SUBSTANTIAL COMPLETION. <br />4. IF THE DUCTWORK AND/OR EQUIPMENT IS FOUND TO BE CONTAMINATED AT ANY POINT DURING CONSTRUCTION, AN <br />INDEPENDENT NADCA CERTIFIED CONTRACTOR SHALL BE RETAINED TO CLEAN THE DUCTWORK AND/OR <br />EQUIPMENT AT THE CONTRACTORS EXPENSE. <br />5. SYSTEM OPERATING TEMPERATURES SHALL BE MAINTAINED TO AVOID CONDENSATION ON DUCTWORK AND <br />EQUIPMENT SURFACES. NEW OR EXISTING INSULATION FOUND DAMAGED SHALL BE REPLACED. <br />6. COORDINATE USE OF AIR HANDLING EQUIPMENT TO MAINTAIN THE REQUIRED PRESSURE RELATIONSHIPS IN <br />CONSTRUCTION AREAS ADJACENT TO OCCUPIED AREAS. <br />APPLICABLE CODES <br />2014 FLORIDA BUILDING CODE <br />2014 FLORIDA EXISTING BUILDING CODE <br />2014 FLORIDA PLUMBING CODE <br />2014 FLORIDA FUEL GAS CODE <br />2014 FLORIDA MECHANICAL CODE <br />FLORIDA FIRE PREVENTION CODE, 5TH EDITION (2014) <br />NFPA 10-2010, STANDARD FOR PORTABLE FIRE EXTINGUISHERS <br />NFPA 13-2010, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS <br />NFPA 70-2011, NATIONAL ELECTRICAL CODE <br />NFPA 72-2010, NATIONAL FIRE ALARM CODE <br />NFPA 75-2009, STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT <br />NFPA 99-2012, STANDARD FOR HEALTH CARE FACILITIES <br />NFPA 101-2012, LIFE SAFETY CODE, EXCEPT AS MODIFIED BY FLORIDA STATE STATUTE <br />NFPA 110-2010 EDITION, STANDARD FOR EMERGENCY & STANDBY POWER SYSTEMS <br />NFPA 241-2009, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION & DEMOLITION OPERATIONS <br />LOCAL CODES AND ORDINANCES WHERE APPLICABLE AND FLOOD DAMAGE PREVENTION ORDINANCES <br />GUIDELINES FOR DESIGN & CONSTRUCTION OF HOSPITAL AND HEALTHCARE FACILITIES, 2010 EDITION <br />MECHANICAL DEMOLITION NOTES <br />1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE CONDITION OF ALL EXISTING EQUIPMENT, EXACT <br />SIZES OF EXISTING DUCT AND PIPING, ETC. BEFORE DEMOLITION WORK IS BEGUN. REPORT ANY DISCREPANCIES <br />BETWEEN PLANS AND ACTUAL FIELD CONDITIONS TO ARCHITECT AND ENGINEER PRIOR TO THE COMMENCEMENT OF <br />DEMOLITION WORK. <br />2. REMOVE THE INDICATED HVAC ITEMS AS SHOWN ON PLANS. THIS INCLUDES ALL HANGERS, STRAPS AND <br />RELATED MATERIAL. IF THE OWNER WISHES TO UTILIZE THE EXISTING EQUIPMENT, CONTRACTOR SHALL MOVE <br />THE EQUIPMENT TO AN ON -SITE LOCATION DESIGNATED BY THE OWNER. ALL EQUIPMENT REFUSED BY OWNER <br />SHALL BE DISPOSED OF IN A MANNER ACCEPTABLE BY LOCAL JURISDICTION. ITEMS SHOWN TO BE REMOVED <br />SHALL NOT BE ABANDONED IN PLACE. <br />3. PATCH OPENINGS IN WALLS WITH LIKE MATERIALS TO MAINTAIN THE INTEGRITY OF THE WALL WHERE AIR DEVICES, <br />DUCTS, PIPING, ETC. HAVE BEEN REMOVED. <br />4. GENERAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND ELECTRICAL CONTRACTOR ALL CEILING <br />REMOVAL WHICH IS REQUIRED TO ACCESS THEIR WORK AND IS NOT DESIGNATED FOR REMOVAL. NOTIFY ARCHITECT <br />AND OWNER PRIOR TO COMMENCING REMOVAL. IF EXISTING CEILING IS DETERMINED TO REQUIRE REMOVAL, <br />REMOVE ONLY THAT PORTION NECESSARY TO ACCESS AND COMPLETE DEMOLITION AND NEW WORK. UPON <br />COMPLETION OF THE ABOVE CEILING WORK, CEILING IS TO BE REPLACED TO MATCH EXISTING CEILING. <br />MECHANICAL GENERAL NOTES <br />1. CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE PROJECT SCOPE, UTILITY CONNECTIONS, <br />AND ALL BUILDING SERVICES. <br />2• MAINTAIN ACCESSIBILITY OF ALL EQUIPMENT, DAMPERS, CONTROL PANELS, VALVES, AND OTHER DEVICES. PROVIDE <br />ACCESS PANELS AS REQUIRED. COORDINATE PLACEMENT WITH THE ARCHITECT PRIOR TO INSTALLATION. <br />3. STANDARD DETAILS ILLUSTRATED ON THE DRAWINGS SHALL BE APPLIED IN ALL CASES WHERE THE FEATURE <br />OCCURS IN THE SYSTEM DESIGN. <br />4• DRAWINGS ARE SCHEMATIC IN NATURE AND SHALL NOT BE SCALED. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING EXACT ROUTING OF ALL SERVICES WITH EXISTING CONDITIONS AND WITH ALL OTHER TRADES. <br />5. MAJOR EQUIPMENT SHOWN ON THE PLANS AND ELEVATIONS ILLUSTRATE THE GENERAL ARRANGEMENT AND SPACE <br />ALLOCATIONS. THE CONTRACTOR SHALL VERIFY THE SPACE REQUIREMENTS FOR EACH SYSTEM COMPONENT USING <br />MANUFACTURER CERTIFIED SHOP DRAWINGS AND MAKE THE NECESSARY ADJUSTMENTS IN EQUIPMENT PLACEMENT <br />AND CONNECTION IN ORDER TO ACCOMMODATE THE EXACT EQUIPMENT TO BE INSTALLED. <br />6• PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SLEEVED, SEALED AND FIRESAFED TO MAINTAIN <br />THE INTEGRITY OF THE WALL AND FLOOR UL FIRE RESISTANCE RATING. <br />7. CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT PRIOR TO CUTTING ANY OPENING IN THE STRUCTURE. <br />8. PROVIDE EXPANSION JOINT AT EACH PIPE AND DUCT CROSSING AN INTERIOR BUILDING EXPANSION JOINT. <br />9. WHERE WORK IN RENOVATED AREAS AFFECTS SYSTEMS IN OTHER AREAS OF THE BUILDING, THE CONTRACTOR <br />SHALL COORDINATE THIS WORK WITH THE OWNER. THIS WORK SHALL BE DONE TO FIT THE BUILDING OPERATIONAL <br />SCHEDULE AND MINIMIZE DISRUPTION/ DISCOMFORT TO OCCUPIED AREAS. PROVIDE MINIMUM 48 HOURS WRITTEN <br />NOTICE WITH ANTICIPATED DURATION OF OUTAGE. <br />10. COORDINATE WITH ALL TRADES FOR REQUIRED CEILING REMOVAL IN EXISTING BUILDING. NOTIFY THE ARCHITECT <br />AND OWNER PRIOR TO COMMENCING REMOVAL. REMOVE ONLY THAT PORTION OF CEILING NECESSARY TO ACCESS <br />AND COMPLETE THE NEW WORK. UPON COMPLETION OF THE ABOVE CEILING WORK, CEILING IS TO BE REINSTALLED. <br />REPLACE ANY DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING. <br />11. FABRICATE DUCTWORK FROM GALVANIZED SHEET METAL MEETING SMACNA STANDARDS. SEAL DUCT ACCORDING <br />TO SMACNA SEAL CLASS A FOR ALL SUPPLY, RETURN AND EXHAUST DUCTS. <br />MECHANICAL SHEET INDEX <br />SHEET <br />NUMBER <br />DESCRIPTION <br />M001 <br />MECHANICAL NOTES, SCHEDULES AND SHEET INDEX <br />M002 <br />MECHANICAL SPECIFICATIONS <br />M003 <br />MECHANICAL SPECIFICATIONS <br />M300 <br />MECHANICAL PARTIAL FLOOR PLAN - DEMOLITION & NEW CONSTRUCTION <br />M501 <br />MECHANICAL DETAILS <br />AA 26001479 <br />Sheet Notes: <br />Smith <br />Seckman <br />SRReid, Inc. <br />301 North Cattlemen Road, Suite 300 <br />Sarasota, FL 34232 <br />(941) 907-7750 <br />FAX: (941) 907-7751 <br />www.ssr-inc.com <br />Firm Certification - CA-0000857 <br />SSR# 1636044.0 <br />Erick Phelps - PE #64598 <br />Christopher E. Durham - PE 976655 <br />qyGK PH, <z <br />i <br />No. 64598 <br />FF <br />STATE OF •• �(/�` <br />�T�•• :cLORIOP.•••G��� <br />,Il�NA �0\\� <br />ERICK PHELPS <br />PE - 64598 <br />FI f -A [7) <br />Lk_j ixi DA CA N C' E R <br />& Research Institute <br />Key Plan <br />MARK ISSUE DATE DESCRIPTION <br />Issue Log <br />CONSTRUCTION <br />DOCUMENTS <br />FLORIDA CANCER SPECIALISTS <br />EQUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVE. <br />ZEPHYRHILLS, FL 33540 <br />Drawing Title <br />MECHANICAL NOTES, <br />SCHEDULES, AND SHEET <br />INDEX <br />71604 <br />07/15/2016 <br />Scale NTS <br />Sheet Number <br />M001 <br />Drawn By DAO <br />Approved By EAP <br />Filename <br />SaLtCo, LLC 2007 <br />