Laserfiche WebLink
PIERNNCE 45 <br />Provide R-19 Batt Insulation <br />for continuously Insulated <br />building envelope <br />tongue and groove <br />soffit to match <br />existing <br />tongue and groove <br />fcscla on 2x <br />wood framing to <br />match existing <br />112' painted <br />sand float <br />finish stucco <br />�l <br />(2) layers 1' rigid fall faced Insulation <br />on 3 518' metQJ studs with <br />Existing wood truss framing to remain <br />Remove lower portion of shakes to <br />accommodate low slope roofing <br />Extend base flashing up under shakes and <br />underloyment, seal watertight <br />4' cant strip <br />Low slope roofing on tapered rigid Insulation <br />minimum 114' per foot slope R-20 <br />Remove lower portion of shingles, extend <br />low slope roofing up under shingle <br />underlayment. Seal watertight <br />Roof droln, refer <br />roof plan <br />518' gypsum board and framing <br />�— Existing column beyond <br />/ <br />------------------------------ i---i <br />Remove existing truss overhang, <br />fascia and soffit to extent shown <br />518' gypsum board on 3 518' metal <br />studs at 16' oc. Refer reflected ceiling <br />plan <br />\_2x Roof framing <br />Backllt sky panel <br />Remove existing <br />face brick <br />K <br />Base <br />Extend rating to underside of <br />deck. inflll with fire sofIng <br />insulation as required <br />Existing Batt Insulation augment as <br />required for continuously Insulated <br />building envelope minimum R-19 <br />Existing Truss B <br />Existing gypsum membrane. <br />Patch as required Reply <br />Typh <br />Exi, <br />rem <br />rep( <br />Lay -In acoustical ceiling <br />r <br />K <br />Prop <br />retu <br />ALu <br />fro <br />112 <br />fin! <br />12' <br />unij <br />6' c <br />Pat <br />as <br />518' gypsum board <br />/layer rigid insulation — <br />(2) layers rlgld insulation <br />518' gypsum board <br />on 3-518' metal <br />stud ceiling <br />(2) edge beads and <br />caulk at gypsum <br />board corner <br />Existing structure to remain <br />Soffit on Ix firring. <br />Match existing <br />Existing header <br />3-518' metal studs at 16'o.c. <br />Provide sealant and backer rod between <br />soffit Y channel and stucco <br />112' stucco on 12' He beam. <br />Project No. 14037.00 <br />A461 <br />© 2015 BH/PK Architects,© 2015 BH/PK Architects, InCI <br />61312015 8:48:01 AM _Acd\A4.1 Sectlons.dgn <br />