8 <br />0 <br />N <br />INSTALL APPROXIMATLY 12" <br />ABOVE FINISHED FLOOR — <br />EXISTING FLOOR <br />WATER SERVICE INTO <br />BUILDING <br />2 PIECE FULL PORT <br />BRASS BALL VALVE <br />INCOMING WATER SERVICE FROM BELOW <br />GRADE TO 5'-0" OUTSIDE OF BUILDING <br />(END OF PLUMBING CONTRACT) <br />CREFER TO CIVIL DRAWINGS FOR) <br />CONTINUATION OF PIPING / <br />y� y�\��\ <br />\�� WATERTIGHT PIPE SLEEVE <br />MAIN BUILDING SHUT-OFF VALVENOT TO SCALE <br />I <br />RULE 1: BRANCH LINES OF 20 FEET OR LESS. <br />THE HAMMER ARRESTOR SHOULD BE PLACED AT THE END OF THE BRANCH LINE BETWEEN THE LAST TWO FIXTURES. <br />RULE 2: BRANCH LINES OVER 20 FEET. <br />AN ADDITIONAL HAMMER ARRESTOR (Y) SHOULD BE PLACED AS SHOWN (BELOW). THE ADDITIONAL UNIT PLACED AT THE <br />MIDPOINT OF THE RUN LONGER THAN 20 FEET. THE SUM OF THE FIXTURE UNIT RATINGS OF (X) AND (Y) COMBINED, <br />SHOULD BE EQUAL TO OR GREATER THAN THE DEMAND OF ALL BRANCHES. <br />HAMMER <br />ARRESTOR <br />MAIN LINE or <br />RULE 1 <br />BRANCH LINE <br />UNDER 20 FEET — <br />ARRESTOR STOR ARRESTOR <br />MAIN LINE RULE 2 Y X <br />BRANCH LINE <br />OVER 20 FEET — <br />WATER HAMMER ARRESTOR DETAIL <br />NOT TO SCALE <br />HOT WATER FROM BALL VALVE <br />WATER HEATERS (NORMALLY CLOSED) <br />TEMPERED (HOT) WATER TO <br />,",,-BUILDING (TEMP. TO BE SET AS PER <br />FULL SIZE IOWNER'S REQUIREMENTS, 110'F) <br />BY-PASS 3 F DIELECTRIC <br />TRIC <br />ID OEI <br />HEAT TRAP <br />(28" DROP) <br />/— BALL VALVE (TYP) <br />FINISHED WALL <br />STAINLESS STEEL <br />FLUSH COVER PLATE <br />WITH SECURING SCREW <br />CLEANOUT TEE <br />WALL CLEANOUT DETAILNOT TO SCALE <br />COUNTERTOP <br />\ ..._ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />3/8" COLD WATER \ <br />' SUPPLY FROM SINK <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ <br />TOE CLEARANCE <br />REFRIGERATOR <br />METAL POWERED COATED <br />20 GAUGE RECESSED <br />MOUNTED VALVE BOX <br />1/4 TURN VALVE <br />WITH HAMMER <br />_r • ARRESTOR <br />THRU WALL <br />EXPOSED IN -LINE <br />AQUA -PURE FILTER <br />MODEL AP717 .5 GPM FLOW <br />IN CABINETRY <br />EXPOSED IN -LINE <br />BACKFLOW PREVENTER <br />WATTS SERIES 7 <br />REFRIGERATOR ICE MAKER <br />CONNECTION DETAIL <br />C� COLD WATER FROM <br />MAIN SUPPLY <br />STRAINER <br />BALANCING NOTES CHECK VALVE <br />1. WITH BALL VALVE CLOSED, SET MIXING VALVE TO DESIRED TEMPERATURE WITH WATER FLOWING FROM <br />TEMPERED WATER LINE. <br />2. AFTER OBTAINING DESIRED TEMPERATURE, STOP THE WATER FLOW. <br />3. CRACK THE BALL VALVE SO THAT A SMALL AMOUNT OF WATER IS RETURNED TO THE HOT WATER SOURCE. <br />THIS WILL ALLOW THE MIXING VALVE TO MAINTAIN THE SET TEMPERATURE DURING PERIODS OF NO DRAW. <br />4. OBSERVE THE TEMPERATURE ON THE DISCHARGE OF THE MIXING VALVE. IF THE TEMPERATURE INCREASES <br />ABOVE THE SETTING IN STEP 1, CLOSE THE BALL VALVE SLIGHTLY OR IF THE TEMPERATURE DECREASES, <br />OPEN IT SLIGHTLY. <br />5. REMOVE BALL VALVE HANDLE AFTER SYSTEM BALANCED AND TURN OVER TO OWNER WITH BALANCING <br />INSTRUCTIONS. <br />WALL MOUNTED THERMOSTATIC WATER CONTROLLER DETAIL NOT <br />TO <br />�[ <br />EXTERIO1 <br />BRICK FA <br />EXTERIOR <br />RECESSED WALL BOX <br />18"-2 <br />FROM <br />RECESSED CONC. <br />WALL BOX <br />FRONT <br />EXISTING FLOOR <br />NOT TO SCALE <br />System No. W—L-1054 <br />F Ratings — 1 and 2 Hr (See Items 1 and 3) <br />T Rating — 0 Hr <br />L Rating At Ambient — Less Than 1 CFM/Sq Ft <br />L Rating At 400 F — 4 CFM/Sq Ft <br />SECTION a -a <br />10R 2 HOUR FIRE RATE WALL PIPI <br />1. Wall Assembly -- The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of <br />the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs <br />in the UL Fire Resistance Directory and shall include the following construction features: <br />A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of <br />nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. <br />When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be <br />framed on all sides using lengths of steel stud installed between the vertical studs and screw -attached to the <br />steel studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 in. higher than <br />the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 <br />in. clearance is present between the penetrating item and the framing on all four sides. <br />B. Gypsum Board* -- 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, <br />thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual <br />U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32-1/4 in. <br />for steel stud walls. Max diam of opening is 14-1/2 in. for wood stud walls. <br />The F Rating of the firestop system is equal to the fire rating of the wall assembly. <br />2. Through -Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically <br />within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. Pipe may be installed with <br />continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from <br />perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types <br />and sizes of metallic pipes, conduits or tubing may be used: <br />A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe -- Nom 30 in. diam (or smaller) cast or ductile iron pipe. <br />C. Conduit -- Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. <br />D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. <br />E. Copper Pipe -- Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. <br />3. Fill, Void or Cavity Material* -- Sealant -- Min 5/8 in. thickness of fill material applied within the <br />annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and <br />wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces <br />of wall. (HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-One Sealant) <br />*Bearing the UL Classification Mark <br />NG P'ENTRATION DETAIL <br />FLOOR DRAIN WITH TRAP <br />PRIMER CONNECTION <br />EXISTING FLOOR SLAB <br />—t—�=ij=-1---- <br />D <br />NON -SHRINK GROUT <br />DEEP SEAL P TRAP <br />FLOOR DRAIN DETAIL <br />NOT TO SCALE <br />3/4 "WATER SUPPLY <br />=ROM CEILING <br />"YPSUM WALL <br />METAL STUD <br />� EXTERIOR WALL HYDRANT DETAIL„o„oIC„EJ <br />n nnn <br />TRAP GUARD DETAIL <br />EXISTING FLOOR SLAB <br />n C-- <br />D n D I <br />/i RhM <br />FLOOR SINK DETAIL <br />TRAP <br />(TYPICAL) <br />NOT TO SCALE <br />FLOOR SINK WITH REMOVABLE <br />GRATE AND SEDIMENT BUCKET <br />FLUSH WITH FLOOR <br />D �D <br />° <br />° <br />D n <br />D ° <br />-SHRINK GROUT <br />DEEP SEAL P TRAP <br />NOT TO SCALE <br />0wARD4fo� <br />��CENSF,G,92r.�� <br />40193 <br />r <br />�s •4 RIB, <br />OMhM <br />Project No. 151010 <br />NOT FOR CONSTRUCTION <br />P5,0 <br />Z:\BH_PK Architects\151010 — FH (Zephyrhills) — Wellness Center\Des1gn\151010_P5.0.dwg Monday, February 14, 2011 3:34:45 PM Shawn Jeffrey <br />PAW am <br />aDA 33619 <br />2 1-SM <br />Z4t-em <br />V= <br />02015 BH/PK Architects, Inc. <br />