N <br />N <br />N <br />SPIN -IN FITTING WITH BUTTERFLY DAMPER <br />ROUND "SNAPLOCK" SHEET METAL OR SPIRAL LOCKSEAM FOR RUNOUTS <br />GREATER THAN 5 FT., WITH WRAP INSULATION (SAME AS DIFFUSER NECK) <br />SUPPORT WIRE TO PREVENT FLEXIBLE DUCT: INSULATED (SAME SIZE AS <br />SUPPORT SAGS & KINKS IN FLEX DIFFUSER NECK) DO NOT SAG OR KINK <br />AS PER <br />SMABAND CLAMP AND TAPE FLEX DUCT <br />rj <br />STANDARDS TO HARD ROUND ELBOW <br />HARD ROUND ELBOW <br />SHEET METAL (SAME SIZE AS <br />DIFFUSER NECK) <br />THREE SHEET METAL <br />SCREWS THRU HELIX OF <br />R-6 INSULATION HARD DUCT, BAND <br />SUPPLY DUCT OVER CEILING DIFFUSE CLAMP & TAPED <br />WRAP INSULATION i <br />CEILIN DIFFUSE <br />FLEXIBLE DUCTS SHALL BE CONFIGURED AND SUPPORTED SO AS TO PREVENT THE USE OF EXCESS DUCT MATERIAL, PREVENT DUCT <br />DISLOCATION OR DAMAGE, AND PREVENT CONSTRICTION OF THE DUCT BELOW THE RATED DUCT DIAMETER IN ACCORDANCE WITH THE <br />FOLLOWING REQUIREMENTS: <br />1. DUCTS SHALL BE INSTALLED FULLY EXTENDED. THE TOTAL EXTENDED LENGTH OF DUCT MATERIAL SHALL NOT EXCEED 5 PERCENT OF THE <br />MINIMUM REQUIRED LENGTH FOR THAT RUN. <br />2. BENDS SHALL MAINTAIN A CENTER LINE RADIUS OF NOT LESS THAN ONE DUCT DIAMETER. <br />3. TERMINAL DEVICES SHALL BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCT. <br />4. HORIZONTAL DUCT SHALL BE SUPPORTED AT INTERVALS NOT GREATER THAN 5 FEET (1524 MM). DUCT SAG BETWEEN SUPPORTS SHALL NOT <br />EXCEED 1/2 INCH PER FOOT OF LENGTH. SUPPORTS SHALL BE PROVIDED WITHIN 6 INCHES (152 MM) OF INTERMEDIATE FITTINGS AND <br />BETWEEN INTERMEDIATE FITTINGS AND BENDS. CEILING JOISTS AND RIGID DUCT OR EQUIPMENT MAY BE CONSIDERED TO BE SUPPORTS. <br />5. VERTICAL DUCT SHALL BE STABILIZED WITH SUPPORT STRAPS AT INTERVALS NOT GREATER THAN 6 FEET (1829 MM). <br />6. HANGERS, SADDLES AND OTHER SUPPORTS SHALL MEET THE DUCT MANUFACTURER'S RECOMMENDATIONS AND SHALL BE OF SUFFICIENT <br />WIDTH TO PREVENT RESTRICTION OF THE INTERNAL DUCT DIAMETER. IN NO CASE SHALL THE MATERIAL SUPPORTING FLEXIBLE DUCT THAT IS <br />IN DIRECT CONTACT WITH IT BE LESS THAN 11/2 INCHES (38 MM) WIDE. <br />I <br />TO <br />DRAIN <br />CLEANC <br />OPE <br />WAR <br />AIN <br />MINIMUM 3/4" INSULATED COPPER <br />nnunrur•rr niniun <br />DRAW-THRU UNIT <br />X = 1-1/2 Y <br />Y = MIN. OF 1" + UNIT STATIC PRESSURE <br />TOTAL HEIGHT = X+Y+(1-1/2"xPIPE 0) <br />CEILING DIFFUSER RUNOUT DETAIL (CONDENSATE DRAIN TRAP DETAIL NOT TO <br />NOT TO <br />I FAN r---- <br />1 � <br />HANGER SUPPORTS: 1" X 22 GA, <br />DO NOT SUPPORT FROM CEILING. <br />INTEGRAL BACKDRAFT DAMPER <br />` VARIABLE SPEED CONTROLLER <br />MARK WITH THE "AS BALANCED <br />POSITION" <br />DISCONNECT SWITCH: FURNISHED <br />BY MECHANICAL CONTRACTOR OR <br />FAN MANUFACTURER <br />CEILING TILE <br />CEILING MOUNTED FAN DETAILNOT ,oSCALE <br />I <br />PIPE CLAMP, "B-LINE <br />ARMAFIX IPH" WITH CUSHION <br />BETWEEN PIPE & CLAMP. <br />REFRIGERANT ° �' SIZE TO MATCH PIPING. <br />PIPING <br />' o <br />SUPPORT CHANNEL, "UNISTRUT" <br />1-5/8" WIDTH SERIES <br />NOTES <br />1. ROUTING OF ALL REFRIGERANT PIPING SHALL BE PLUMB AND SHALL RUN TRUE WITH THE BUILDING <br />LINES. HORIZONTAL RUNS OF SUCTION LINES OF 25' SHALL BE PITCHED 1 /2 BUBBLE TOWARD THE <br />COMPRESSOR, FOR OIL RETURN. <br />2. BRAZE REFRIGERANT PIPING WITH FLOW OF DRY NITROGEN DURING BRAZING. <br />3. SUPPORT OF ALL PIPING AT COMPRESSORS, CONDENSERS, AND AIR HANDLING UNITS SHALL BE AS <br />SHOWN ABOVE. SUPPORT OF PIPING IN BETWEEN THE UNITS SHALL BE WITH STRAP MATERIAL, USING <br />ARMAFLEX INSULATION AS SADDLES. NO METAL - TO - METAL CONTACT. <br />4. INSULATE SUCTION LINE WITH 3/4" ARMAFLEX INSULATION FULL LENGTH. APPLY ARMAFLEX <br />PRESERVATIVE ON ALL INSULATION EXPOSED TO THE EXTERIOR. WHERE REFRIGERANT OR CONDENSATE <br />PIPING RUNS THROUGH RETURN AIR PLENUMS, INSULATION SHALL BE FIRE RATED ARMAFLEX "AP" <br />25/50. <br />5. CHANGE FILTER - DRIER CORES AFTER 30 DAYS OF OPERATION. <br />(REFRIGERANT PIPING DETAIL r o�I <br />HANGER SUPPORTS: <br />8'O.C. = 0-35" DUCTS <br />6'O.C. = 36-59" DUCTS <br />�r <br />STRUCTURAL <br />JOIST (METAL) <br />J <br />STRUCTURAL <br />JOIST (WOOD) <br />1;ii1�11 ]�L�II�IP„IIP�i];a <br />(2) #10 GALVANIZED SCREWS <br />N <br />c� <br />z <br />U <br />SCREWS `� N <br />77- <br />INSULATED <br />RECTANGULAR SHEEP�-- <br />METAL DUCT MIN. <br />NOTES <br />1. USE TRAPEZE HANGERS FOR DUCTS WIDER THAN 59". <br />2. STRAPS SHALL BE MINIMUM 1" X 22 GAGE GALVANIZED STEEL, SEE "RECTANGULAR DUCT HANGERS", <br />SMACNA TABLES 4-1, 4-2. <br />3. NO POP RIVETS ALLOWED, USE SELF -TAPPING SHEET METAL SCREWS ONLY. <br />4. DUCTWORK BELOW BOTTOM TRUSS TO HUNG FROM BOTTOM CHORD OF TRUSS AND DUCTWORK ABOVE BOTTOM OF <br />TRUSS TO BE HUNG FROM TOP CHORD OF TRUSS. <br />HANGER STRAPS <br />TYPICAL DUCT HANGING DETAILNOT �SCALE <br />� <br />-ENERGY RECOVERY CORE <br />FILTER <br />EXHAUST <br />AIR EXHAUST AIR <br />��/ N <br />EXHAUST FAN <br />I v <br />I M <br />I <br />I <br />OUTSIDE OUTSIDE AIR <br />I AIR TO AHU-1,4 <br />I Vi <br />I <br />S/S AHU-1, AHU-2 AND AHU-6 FAN I FILTE <br />DO I SUPPLY FAN <br />INTERLOCK <br />I <br />I I <br />I I <br />S------ -----------------------------� <br />EF-1.2.3.4,5.6,7 <br />UNOCCUPIED <br />UNIT REMAINS OFF WHEN AIR HANDLER IS OFF. OUTSIDE AIR AND EXHAUST <br />DAMPERS CLOSE <br />OCCUPIED <br />SUPPLY AND EXHAUST FAN OPERATES CONTINUOUSLY UPON THE STARTING <br />OF THE AIR HANDLER FAN. OUTSIDE AIR AND EXHAUST DAMPERS OPEN. 0 <br />INTERLOCKED WITH LIGHT SWITCH <br />W/ 10 MIN. TIME DELAY <br />ERV CONTROLS AND SEQUENCE <br />MOTORIZED OA DAMPER RETURN <br />SHALL BE SET OPEN TO AIR <br />REQUIRED OA SUPPLY <br />DURING OCCUPIED MODE <br />I r FILTER <br />AIR <br />SUPPLY <br />FAN <br />SUPPLY <br />AIR <br />ROOM TEMP <br />r— S I I �IJ <br />=I al zl� <br />L-Lc <br />I WI alp <br />~ <br />S/SDO I I Q <br />DI AI <br />DO - - 30 POWER <br />S/S =___ BY DIV.16 <br />_=__ 30 POWER <br />CONDENSING BY DIV.16 <br />UNIT <br />SEQUENCE OF OPERATIONS <br />PACKAGED SPLIT DX SYSTEM SHALL BE CONTROLLED DIRECTLY VIA THE THERMOSTAT. <br />OCCUPIED MODE <br />(COOLING) <br />WHEN THE OCCUPIED MODE IS SELECTED EITHER BY PROGRAM OR TEMPORARY OVERRIDE THE THERMOSTAT WILL <br />ENERGIZE THE SUPPLY FAN AND OPEN THE OUTSIDE AIR DAMPER. IF EQUIPPED, THE ENERGY RECOVERY VENTILATOR <br />SUPPLY AND EXHAUST FANS WILL ENERGIZE VIA A RELAY INTERLOCK. UPON A CALL BY THE THERMOSTAT FOR COOLING <br />THE CONDENSER COMPRESSOR AND CONDENSER FAN WILL ENERGIZE. WHEN THE CALL FOR COOLING IS SATISFIED THE <br />CONDENSER COMPRESSOR AND CONDENSER FAN WILL BE DEENERGIZED. <br />(HEATING) <br />WHEN THE OCCUPIED MODE IS SELECTED EITHER BY PROGRAM OR TEMPORARY OVERRIDE THE THERMOSTAT WILL <br />ENERGIZE THE SUPPLY FAN AND OPEN THE OUTSIDE AIR DAMPER. IF EQUIPPED, THE ENERGY RECOVERY VENTILATOR <br />SUPPLY AND EXHAUST FANS WILL ENERGIZE VIA A RELAY INTERLOCK. UPON A CALL BY THE THERMOSTAT FOR HEATING <br />THE ELECTRIC RESISTANCE COILS IN THE AIR HANDLER ARE ENERGIZED. WHEN THE CALL FOR HEATING IS SATISFIED <br />THE ELECTRIC RESISTANCE COILS IN THE AIR HANDLER ARE DEENERGIZED. <br />UNOCCUPIED MODE <br />(COOLING) <br />WHEN UNOCCUPIED MODE IS SELECTED BY THE THERMOSTAT PROGRAM THE THERMOSTAT WILL SWITCH TO THE <br />UNOCCUPIED TEMPERATURE OPERATION SCHEDULE. THE SUPPLY FAN WILL BE DEENERGIZED AND THE MOTORIZED <br />OUTSIDE AIR DAMPER WILL CLOSE. IF EQUIPPED, THE ENERGY RECOVERY VENTILATOR SUPPLY AND EXHAUST FANS WILL <br />BE DEENERGIZED VIA A RELAY INTERLOCK. UPON A CALL BY THE THERMOSTAT FOR COOLING THE AIR HANDLER FAN <br />MOTOR, COMPRESSOR AND CONDENSER FAN WILL ENERGIZE TO PROVIDE THE NEEDED COOLING. WHEN THE CALL FOR <br />COOLING IS SATISFIED THE AIR HANDLER FAN MOTOR, CONDENSER COMPRESSOR AND CONDENSER FAN WILL BE <br />DEENERGIZED. <br />(HEATING) <br />WHEN UNOCCUPIED MODE IS SELECTED BY THE THERMOSTAT PROGRAM THE THERMOSTAT WILL SWITCH TO THE <br />UNOCCUPIED TEMPERATURE OPERATION SCHEDULE. THE SUPPLY FAN WILL BE DEENERGIZED AND THE MOTORIZED <br />OUTSIDE AIR DAMPER WILL CLOSE. IF EQUIPPED, THE ENERGY RECOVERY VENTILATOR SUPPLY AND EXHAUST FANS WILL <br />BE DEENERGIZED VIA A RELAY INTERLOCK. UPON A CALL BY THE THERMOSTAT FOR HEATING THE ELECTRIC RESISTANCE <br />COILS AND SUPPLY FAN MOTOR IN THE AIR HANDLER ARE ENERGIZED. WHEN THE CALL FOR HEATING IS SATISFIED THE <br />ELECTRIC RESISTANCE COILS AND SUPPLY FAN MOTOR IN THE AIR HANDLER ARE DEENERGIZED. <br />AC CONTROLS AND SEQUENCENOT TO SCA <br />AIR HANDLER <br />FLEXIBLE CON <br />SUPPLY DUCT <br />1/2" RUBBERIZED CORK PAD OVER —� <br />FULL LENGTH BELOW AHU <br />PROVIDE 2" DEEP AUXILIARY DRAIN PAN <br />WITH FLOAT SWITCH INTERLOCKED <br />TO SHUTDOWN UNIT <br />NOTE: SLOPE AUXILIARY DRAIN PAN SLIGHTLY TOWARDS FLOAT SWITCH. <br />SUSPEND UNIT FROM STRUCTURE <br />W/ THREADED ROD. PROVIDE <br />SUPPLEMENTAL FRAMING AS REQ'D <br />FLEXIBLE CONNECTION <br />RETURN DUCT <br />`— FILTER <br />CONDENSATE DRAIN "P" TRAP <br />TYPICAL HORIZONTAL AIR HANDLING UNITNOT TO <br />SCALE <br />NOTES <br />(D CONDENSING UNIT SHALL BE INSTALLED TO RESIST WIND PRESSURES IN ACCORDANCE WITH FLORIDA BUILDING <br />CODE, MECHANICAL, SECTION 301.12. SECURE UNIT TO ANGLE IRON USING #12 S.S. SCREW (TYP. OF 4 <br />CORNERS) AND 3"x2"x3/16" ANGLE IRON. <br />O2 1/4"x1-3/4" HEX SLEEVE CONCRETE ANCHORS WITH WASHER AND NUT INSTALLED THROUGH ANGLE IRON IN NEW <br />HOUSEKEEPING PAD (TYP. OF 4 CORNERS) <br />EXTERIOR WALL <br />CONDENSING <br />PROVIDE SLEEVE <br />= IN WALL AND <br />SEAL PENETRATION <br />ON BOTH SIDES. <br />6" MIN. OR AS = _ _ _ = UNISTRUT <br />OTHERWISE NOTED <br />GRADE 1 =_ __ __ __ __ FLOOR <br />JA <br />2 a b, <br />lk <br />Al <br />4" THK. CONC. PAD <br />4 <br />FOOTING <br />CONDENSING UNIT DETAIL <br />NOTES <br />O CONDENSING UNIT SHALL BE INSTALLED TO RESIST WIND <br />PRESSURES IN ACCORDANCE WITH FLORIDA BUILDING CODE, <br />MECHANICAL, SECTION 301.12. SECURE UNIT TO ANGLE <br />IRON USING #12 S.S. SCREW (TYP. OF 4 CORNERS) AND <br />3"x2"x3/16" ANGLE IRON. <br />WALL 3M FS-195 WRAP/STRIP 2 1/4"x1-3/4" HEX SLEEVE CONCRETE ANCHORS WITH <br />AND CP 25 CAULK O WASHER AND NUT INSTALLED THROUGH ANGLE IRON IN NEW <br />STAINLESS STEEL TO MAINTAIN FIRE RATING <br />ESCHUTCHION HOUSEKEEPING PAD (TYP. OF 4 CORNERS) <br />PLATE IN FINISHED <br />AREAS ONLY <br />PIPE & INSULATION <br />(WHERE APPLICABLE) <br />CONDENSING UNIT <br />— — — — — — — — J �— — — — — — — — — — — — — — — — <br />INSULATED <br />REFRIGERANT <br />--------I I----------- - - - - -- <br />PIPING <br />SEALANT - 3M .� UNISTRUT <br />PIPE OR FIRE BARRIER 1 <br />OR EQUAL <br />CONDUIT <br />SLEEVE ME:-, <br />j <br />l—i W�' ,IR <br />Ill —I j l" <br />-I I I-4 3 HOUSEKEEPING EPAD = I=I 6 1=1 11=1 I I =l <br />-1 I F—Ml i 11 l if i 4il(iTil l lfil�� 1 �4iIk_�_�� • • <br />RATED WALL PENETRATION DETAILNOT TO SCALE <br />EXTERIOR WALL <br />REFRIGERANT <br />PIPING ABOVE <br />CEILING <br />MINI —SPLIT UNIT ON GRADE DETAILNOT TO SCALE <br />Project No. 151010 <br />NOT FOR CONSTRUCTION <br />M4,0 <br />Z:\BH_PK Architects\151010 - FH (Zephyrhills) - Wellness Center\Design\151010_M4.0,dwg Monday, February 14, 2011 3:34:45 PM Shawn Jeffrey <br />12r, <br />rewns � v.>I—e,ee <br />I I r.a �FAx U. <br />2ti_ f Q2015 BH/PK Architects, Inc. <br />