Laserfiche WebLink
- — — _ LL ! _ --- - <br />STRUCTURAL SHEATHING, SEE PLAN AND DETAILS FOR ATTACHMENT <br />PRE-ENGINEERED WOOD <br />- <br />TRUSSES AT 24' O.C. MAX. <br />OR, <br />2z BLOCiQdG AT SHEATHING <br />2z RIBBON BOARD ATTAIDErAL <br />EDGES wl (3) 8d NAILS INTO TRUSS <br />TO TRUSS wl (3)1 Od NAIL <br />CONTINUOUS STRUCTURAL <br />O.C. CENTER MAX. SPACING <br />SHEATHING NAIL PER TYPICAL <br />CONTINUOUS STRU <br />SHEATHING DETAIL <br />SHEATHING NAIL PER <br />TYPICAL TRUSS <br />SHEATHINGANCHOR <br />PER PLAN <br />DETAIL AT TRUSS HEEL > 9114' <br />T <br />ANCHOR PER PLAN <br />NOTE: <br />REFER TO ARCHITECTURAL DRAWINGS ANDIOR TRUSS MANUFACTURER DRAWINGS FOR <br />SPECIFIC TRUSS PROFILE INFORMATION. (Le. HEEL. HEIGHTS, SLOPE, OVERHANGS) <br />STRUCTURAL SHEATHING, <br />SEE PLAN AND DETAILS FOR <br />ATTACHMENT <br />PRE-ENGINEERED WOOD <br />TRUSSES AT 24' O.C. MAX. <br />TRUSS ANCHOR <br />PER PLAN <br />FASCIA, (SEE ARCH DWGS) <br />BOND BEAM PER PLAN <br />DETAL AT TYPICAL TRUSS wl HEEL < 9114' <br />__:`\�ROOFTRUSS ON MASONRY <br />IV 1 Scale: File Name: <br />1 /2"=1'-0" RZ-010 <br />SHEATHING SEE PLAN <br />FOR ATTACHMENT <br />PRE ENGINEERED <br />TRUSSES AT 24" O.C. <br />2x4 BLOCKING AT 2'-0" <br />O.C. w/ (2) 12d TOE NAILS <br />EACH END TO TRUSS <br />BOND BEAM PER SHEATHING PER PLAN <br />PLAN AND SCHEDULE META16 AT BLOCKING w/1/4" <br />8" CMU WALL. SEE PLAN MAX. GAP FROM TOP OF <br />FOR VERT. REINF. WALL TO BOTT. OF BLOCKING <br />R07 �AL�LBR�AC�ING�AT�NO-BEARI�GEXTERIO�RW ALL <br />STRUCTURAL <br />SHEATHING PER PLAN <br />PRE ENGINEERED — <br />TRUSSES AT 24' O.C. <br />TRUSS ANCHOR <br />PER PLAN <br />BOND BEAM PER PLAN J <br />AND SCHEDULE SHEATHING <br />Am PER PLAN <br />R08B V�AL�LB�RAC�ING�ABEA�RING WALL <br />(8) 10d NAILS EACH `. <br />(4) 1 /4' 0 c 2-1/4' W <br />ENGINEERED WOOD <br />ROOF TRUSS AT 24" <br />O.C. MAX. <br />CMU WALL <br />SCREWS AT EACH STRAP. (1) SIMPSON HTSM16 <br />CONDTIONS OF USE: (OR APPROVED EQUAL) <br />1. QUANTITY OF MISSED STRAPS DOES NOT EXCEED FIVE (5) CONSECUTIVE LOCATIONS. AT EACH MISSED <br />2. UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1,175 Ibs. UPLIFT. LOCATION. <br />3. NOT ACCEPTABLE ON MULTI -PLY TRUSS APPLICATIONS. <br />IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. <br />CR13 MISSED TRUSS STRAP REPAIR <br />(TYPICAL CMU WALL CONNECTION) <br />STRUCTURAL SHEATHING PER PLAN <br />20 LADDER FRAMING AT 24" O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24' O.C. <br />CONT. 20 w/ (2) 12d NAILS <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 "L" BACK. <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 20 "L" <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />3. AT VERTICALS OVER 8'-4" TO 13'-0" USE ONE 20 <br />"L" BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON H5 <br />CONNECTOR. <br />20 OUTLOOKER <br />PER DRAWINGS <br />2x6 FASCIA <br />1x6 w/(3) 8d <br />EA. OUTLOOKER <br />20 OUTLOOKER <br />PER DRAWINGS <br />2x4 FASCIA <br />-SHEATHING D <br />PER PLAN. _ OR <br />_ <br />- GABLE TRUSS <br />PER PLAN <br />2x4 BETWEEN EA. <br />OUTLOOKER w/(2) <br />10d TOENAILS <br />EDIMENT BLOCKING @ GABLE <br />-VALLEY SET TRUSSES <br />AT 24" O.C. <br />-ROOF SHEATHING <br />PER PLAN <br />-MIN. 9' LONG 20 GA. <br />FLAT STRAP w/ (8) 1Od <br />-SHEATHING PER _ OR <br />I\ <br />_ <br />PLAN. <br />2x4 BLOCKING UNDER TRUSS <br />ENDS. NAIL TO TRUSS CHORDS <br />w/ (3) 10d EACH END. <br />pnQVALLEY SET OVER FRAME <br />SHEATHING <br />PER PLAN. <br />GABLE TRUSS <br />PER PLAN <br />VALLEY SET TRUSSES <br />AT 24' O.C. <br />ROOF SHEATHING <br />PER PLAN <br />PRE-ENGINEERED ROOF <br />TRUSSES 0 MAX. 24° O.C. <br />SHEATHING PER ARCH 10 FURRING AT <br />INSTALLED PER MANUF. MAX. 16' O.C. w/ <br />(3)10d AT EA TRUSS <br />soi EXTERIOR CEILING FURRING <br />SCALE: N.T.S. <br />VALLEY SET TRUSSES <br />AT 24" O.C. <br />ROOF SHEATHING <br />PER PLAN <br />SHEATHING PER p SHEATHING PER <br />PLAN. - OR- \ - PLAN. <br />;_-- -,- - -- _-- ,--- -- - ---I <br />2x4 PURUN 0 EA VALLEY <br />(1) SDWC15600 TRUSS SCREW TRUSS. NAIL TO COMMON <br />TO EVERY TRUSS BELOW TRUSS w/(3) 16d GUN NAILS <br />BOTTOM CORD OF VALLEY <br />TRUSS NAILED TO PURUN <br />w/ 10d GUN NAIL 0 8° O.C. <br />20 BLOCKING AT DIAGONALS ONLY. <br />20 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH <br />ATTACH AT EACH END w/ (2) 12d <br />END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING <br />TOENAILS. NAIL SHEATHING TO <br />AT 6° O.C. w/ MINIMUM 8d NAILS. BLOCK 4 BAYS BACK <br />STRUCTURAL SHEATHING PER PLAN <br />BLOCKING AT 6" O.C. w/ MINIMUM <br />FROM GABLE TRUSS. <br />8d NAILS. BLOCK4 BAYS BACK <br />2x4 LADDER FRAMING AT 2e O.C. REQ'D AT <br />FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />WHEN SECOND BRACE IS REQUIRED, <br />SIDE OF BLOCKING. <br />TOP CHORD w/ (2)-16d NAILS AT 24° O.C. <br />NAIL TO OPPOSITE SIDE OF BLOCKING. <br />CONT. 2x4 w/ (2) 12d NAILS <br />STRUCTURAL SHEATHING <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />PRE-ENGINEERED WOOD <br />BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />3 <br />TRUSSES AT 2'-0° O.C. MAX. 3 <br />SEE PLAN FOR ATTACHMENT OF ALL <br />ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48 <br />STRUCTURAL SHEATHING. <br />O.C. ® APPROX. 45-DEG ANGLE. <br />TRUSS ANCHOR 3 <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE <br />SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T° LAP <br />SEE CONN. CHART <br />2x4 "L" BACK. <br />n NAILED w 2) ROWS 10d GUN NAILS ®8" O.C. <br />/ ( <br />BOND BEAM PER PLA <br />(2) SIMPSON A23 w/ (8) 10d x 1-1/2" <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" <br />"L" <br />USE (2) 20 BACKS (1 EA. SIDE) (OR <br />(ONE ON EACH SIDE OF BRACE TO TOP PLATE). <br />2 (zHTG <br />FRAME PER CASE 3 BELOW) <br />SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d's r SHEATHING PER PLAN <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. PROVIDE CONT. 2x8 P.T. PLATE w/ 1/2" 0 x 10' <br />STRUCTURAL SHEATHING CMU ANCHOR BOLTS AT 4'-0" O.C. MAX. w/2"x2" PL. <br />SEE PLAN FOR ATTACHMENT v u WASHERS AND 7" EMBEDMENT. <br />NAIL BOTTOM CHORD OF GABLE MASONRY WALL, BOND BEAM, LINTEL BEAM OR RAKED <br />BEAM PER PLAN. FOR RAKED BEAM AT VAULTED <br />TRUSS w/ 12d's AT 4" O.C. CONDITION, SEE PLAN AND DETAIL. <br />/ CONY. 2x4 <br />\ 2x4 NAILED FLAT TO TOP OF BRACE ("T" 2x6 NAILED <br />CONTINUOUS / BRACE) NAILED TO DIAG. w/ 10d GUN ®TOP <br />STRUCTURAL NAILS ® 8" O.C. BUTT JOINT ALLOWED <br />SHEATHING SEE PLAN (48" MIN MEMBER LENGTH), BRACED <br />FOR ATTACHMENT REQUIRED TO BE CONTINUOUS OVER DIAG. <br />FIELD NAILING % BRACE SPLICE SHOWN <br />PER PLAN \ 2x4 BLOCKING AT 48" O.C. <br />\ _ / 3 TRUSS BAYS <br />2x6 NAILED 0 BOTTOM <br />FRAMING <br />WOOD PER PLAN GABLE END DIAGONAL BRACE TYPICAL SPLICE <br />R 0 9 "GAB�EEND �TRSS �BRCIN�Gp �T��L <br />—FASCIA x <br />SEE ARCH. BLOCKING <br />DRAWINGS 3. AT VERTICALS OVER 8'-4" TO 13'-0" <br />8" CMU WALL OR USE ONE 20 "L" BACK AND AN <br />LINTEL, SEE PLAN SHEATHING PER JADDITIONAL DIAGONAL BRACE IS REQUIRED <br />FOR REINFORCEMENT PLAN AT THE PEAK AND AT EVERY OTHER <br />MASONRY VERTICAL MEMBER IN THIS RANGE. ATTACH <br />20 DIAGONAL BRACING w/ (5) 12d THE DIAGONAL AT MID HEIGHT AND TO THE <br />COMMON NAILS TO BLOCKING AND BLOCKING BELOW THE ROOF SHEATHING w/ <br />\ TO THE "I" BACK. UNLESS NOTED (5) 12d's AT EACH END. IN ADDITION TO <br />OTHERWISE ON PLANS, PROVIDE THE SECOND DIAGONAL, A STRONGBACK IS <br />ONE BRACE AT THE PEAK AND THE ALSO REQUIRED AT THESE VERICALS AND <br />REMAINDER AT 48" O.C. DIAGONALS MUST BE ATTACHED TO EACH "L" BACK <br />OVER 8'-0" MUST HAVE AN NTH (2) 12d's AND ONE SIMPSON H2.5A <br />TRUSS ANCHOR <br />ADDITIONAL "T" BRACE ATTACHED OR ONE USP RT5 CONNECTOR. <br />SEE CONN. CHART TO THE NARROW EDGE w/ /12d's SIDE NAIL ALL "L" BACKS AND <br />FRAMING PER PLAN AT 6° O.C.. "T' BRACE LENGTH TO STRONGBACKS w/ 12d's AT 6" O.C. NOTCH <br />BE THE DIAGONAL'S LENGTH MINUS "L" BACKS AT TOP AND BOTTOM. <br />12' FROM EACH END. <br />WOOD DUTCH HIP�GABLE�TRU�SS�BRA�CN�GDETAIL <br />(RoqB <br />"X" = 10% <br />HOUSE WIDTH — <br />,O O <br />RIDGE J <br />O GABLE END <br />BOSTON HIP <br />"X" = 10% "X" = 10% OF <br />03 HOUSE WIDTH � HOUSE WIDTH <br />3 <br />x x <br />— 1 2 <br />x Ol 02 3 0 0 / x <br />x x C� <br />RIDGE RIDGE <br />�t GABLE END -- <br />GABLE X ij HIP <br />ROOF SHEATHING <br />NAILS <br />ROOF FASTENING ZONES <br />SHINGLE: <br />7/16° SPAN RATED PLYWOOD OR OSB <br />8d RING SHANK <br />0.113" x 2-3/8" <br />1 <br />2 <br />3 <br />OFFSET DIMENSION "X" = 10% HOUSE WIDTH <br />"X" <br />"X" <br />TILE: 15/32' SPAN RATED PLYWOOD <br />OR OS8 <br />PANEL EDGES @ SUPPORTS (1) <br />6" O.C. <br />6" O.C. <br />4" O.C. <br />PANEL FIELD 1 <br />6" O.C. <br />6" O.C. <br />6" O.C. <br />METAL <br />15/32" SPAN RATED PLYWOOD w/24 GA. <br />19/32" SPAN RATED PLYWOOD w/26 GA. <br />NO I ES: <br />1. LONG SIDE OF SHEATHING TO BE PERPENDICULAR TO TRUSSES OR RAFTERS -TYPICAL. <br />2. EDGE SPACING ALSO APPLIES OVER GABLE END WALLS OR TRUSSES. <br />3. FASTENING ZONES 2 AND 3 ARE EQUAL TO 10% OF TOTAL HOUSE WIDTH, DIMENSION "X" OFFSET FROM ROOF EDGE. <br />30' WIDE HOUSE = 3' ZONE, 40' WIDE HOUSE = 4' ZONE, 50' WIDE HOUSE = 5' ZONE, 60' WIDE HOUSE = 6' ZONE <br />01 ROO��� HEATHIk��ATTACHMEN��b AGRAM <br />2x4 LADDER FRAMING AT 24' O.C. REQ'D AT — <br />OVERHANGS GREATER THAN 12'. ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 2x6 w/ (2) 12d NAILS-----,, <br />STRUCTURAL SHEATHING PER PLAN <br />2x BLOCKING BETWEEN EA <br />TRUSS MEMBER OR TRUSS WEB. <br />2x LEDGER w/2-10d 0 EA. <br />CROSSING TRUSS MEMBER <br />FOR ROOF SHEATHING <br />NAILING <br />20 BLOCKING AT DIAGONALS ONLY. ATTACH AT <br />EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING <br />TO BLOCKING AT 6' D.C. w/ MINIMUM 8d NAILS. <br />BLOCK 8'-0' BACK FROM GABLE TRUSS. <br />20 DIAGONAL BRACING w/ (5) 12d COMMON <br />NAILS EA. E4ND 0 32" MAX. SPACING <br />-'--IF LENGTH IS LESS THAN 4'-0' USE 20 'L" BACK, <br />IF LENGTH IS GREATER THEN 4'-O' USE (2) 2x4 "L" <br />BACKS. NAIL "L' BACKS w/12d 012'O.C.(NOTCHED <br />0 TOP w/2-12d TOENAILS <br />"L" BACK -EXTEND 6' PAST <br />LOWER ROOF SHEATHING <br />SHEATHING PER PLAN-J <br />PARTIAL GABLE END TRUSS DETAIL <br />R09C PARTIAL GABLE <br />C,O.A.# ARCHITECTURE: <br />AA26002802 <br />C.O.A.# ENGINEERING: <br />29349 <br />11 THOMAS A. WEBER, Plc <br />P.E. # 73242 FLORIDA <br />0 BENJAMIN NIESE, PE <br />R.E. # 86025 FLORIDA <br />6m21 <br />DATEtixtllili <br />., No.86 <br />TG , <br />STAY Q <br />O <br />co <br />1 <br />e-I <br />•4-a <br />00 <br />�. <br />0 <br />ul) <br />♦ <br />O <br />00 <br />A� <br />v� <br />a� <br />U� <br />cc! <br />O <br />b� <br />N <br />T� <br />tPulteG-c- <br />PRODUCT MANAGER <br />IRELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE <br />Single Famfl <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />Highgate <br />NPC CHIM NU ER <br />2811.500 <br />SHEET <br />S4.1 <br />